확산형 흡수식 냉동시스템의 기포펌프 성능실험 (Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System)

  • 이재효;정의갑;윤재호;정의갑
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

지역냉방 적용을 위한 LNG냉열 장거리 수송용 제 2종 흡수식 시스템 (Type 2 Absorption Cycle to Transport Energy in the Long Distance for District Cooling Application)

  • 조영경;김진경;오민규;강용태
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.250-255
    • /
    • 2005
  • The objective of this paper is to develop a new energy transport system for district cooling application by using type 2 absorption cycle. Cold energy from the LNG storage system is utilized as the cooling source of the condenser and the rectifier. The pressures of the system, UAs of the evaporator and the desorber, and the inlet temperatures of the refrigerant to each component are considered as the key parameters. The results show that UA of the evaporator is more dominant parameter on COP than that of the desorber and the optimum system pressure for the demand side is estimated as 525 kPa. For the present system, it is recommended that the refrigerant inlet temperature of the evaporator be lower than $4.3^{\circ}C$ for long-distance transportation. It is concluded that the cold energy from the LNG storage system can be effectively applied to the long-distance transportation system for district cooling application with the type 2 absorption cycle. The optimum operation conditions are also predicted from the parametric analysis.

모관양액공급시스템을 이용한 네트멜론 및 엽채소 생육특성 (Growth Characteristics of Net melon and Leaf vegetables to used the Capillary Supplying System)

  • 장전익;김성배
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 2003년도 춘계 학술대회 논문집
    • /
    • pp.30-33
    • /
    • 2003
  • 최근 건강에 대한 인지도가 높아감에 따라 농산물의 안정성 요구도가 증가되고 있으며 환경농업의 필요성이 크게 대두되고 있고, 서구식 식문화의 급속한 도입으로 패스트푸드 식품과 육류 소비량의 증가로 신선채소의 소비가 증가되고 있는데 이에 따른 생산비 절감과 안정생산 기술이 요구되고 있다. 따라서 양액 공급에 따른 전력 등 에너지가 필요치 않고 일종의 폐쇄식 수경재배 방법으로써 작물이 주위 환경에 따라 양수분 흡수량이 다르므로 모세관 현상으로 배지내의 수분이 작물의 흡수한 만큼 공급되어 이용되고 배액이 없으므로 공해의 염려가 없고 고품질 채소의 저비용 생산이 가능한 새로운 모관양액공급시스템을 이용하여 양액공급시스템의 효율성을 검정하고 네트멜론과 몇 가지 엽채소의 생육특성을 구명코자 수행하였다. (중략)

  • PDF

흡수액으로 에틸렌글리콜이 혼합되고 태양열을 이용한 이중효용 흡수식 시스템의 냉방 특성해석 (Analysis of Thermodynamic Design Data for Cooling of Double -Effect Absorption System of Solar Energy using LiBr - water and Ethylene Glycol Mixture)

  • 원승호;박상일
    • 한국태양에너지학회 논문집
    • /
    • 제23권4호
    • /
    • pp.45-54
    • /
    • 2003
  • For cooling of double effect absorption heat pump system of solar heating source, analysis of thermodynamic design data has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data, enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture ($H_2O$ : CHO ratio 10:1 by mole) by computer simulation are done. The obtained results, COP and mass flow ratio of the water - lithium bromide - ethylene glycol system, are compared with data for the water-Libr pair solution.

설비기술 - 평창올림픽 빙상장에 해양심층수 활용한 냉난방 시스템 적용

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • 통권258호
    • /
    • pp.68-70
    • /
    • 2012
  • 평창올림픽 빙상장에 해양심층수를 이용한 냉난방시스템 가동 방안이 추진된다. 국토해양부는 태양광이 도달하지 않는 수심 200m 아래의 해양심층수가 연중 $2^{\circ}C$ 정도를 유지하는 점을 이용해 세계 최초로 올림픽 빙상장에 한국해양연구원의 '해수냉난방시스템' 및 '해수온도차 발전' 연구개발 사업 성과를 적용한다고 밝혔다. 이번 기술이 전기에어컨이나 흡수식 냉동기 등에 적용되면 기존 시스템에 비해 에너지는 60%, 비용은 82%, 이산화탄소 배출량은 64% 줄어들게 된다.

  • PDF

축냉식냉방 및 가스흡수식 냉방시스템의 회피비용 분석 (Avoided Cost Analysis on The Thermal Storage Cooling and Gas Absorption Cooling System)

  • 원종률;황성욱;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.267-268
    • /
    • 2008
  • 부분축열을 기준으로 주로 300RT급 이상에서 주로 보급되고 있으며, 하계 전력수요를 심야로 이전시켜 전력사용의 효율성을 높일 수 있으며 동시에 하계발전설비를 회피할 수 있는 측냉식냉방에 대한 회피비용을 분석하고자 한다. 가격, 비용, 요금 등의 자료를 조사하여 이를 토대로 캘리포니아테스트(RIM, P, UC, TRC)를 분석하여 그 결과를 통해 적정 지원금여부를 판단하고자 한다. 또한 이에 대한 비교대상으로 중대형급에서 같이 보급되고 있는 가스 흡수식 냉방시스템과 비교 분석하고자 한다.

  • PDF

암모니아-물 기포분사형 흡수과정에서의 흡수열 제거를 위한 열전달 특성 연구 (A Study on Heat Transfer Characteristics for Removal of Absorption Heat in Absorption Process of Ammonia-Water Bubble Mole)

  • 이재철;이기봉;전병희;이찬호;하종주;김성현
    • 청정기술
    • /
    • 제7권4호
    • /
    • pp.273-280
    • /
    • 2001
  • 흡수기는 흡수식 열펌프 시스템에서 중요한 구성요소일 뿐만 아니라 흡수기의 성능은 전체 시스템에 중요한 영향을 미친다. 본 연구에서는 기포분사형 흡수기에서의 암모니아기체의 흡수열의 효과적 제거를 위한 냉각수 방향으로의 열전달에 대해 실험적 연구를 수행하였다. 흡수기에 유입되는 암모니아 기체의 유속, 암모니아 수용액의 유속, 농도, 온도, 흡수기의 지름, 높이, 기체와 용액의 유입 방향등 여러 가지 변수에 대하여 열전달 성능의 특성을 살펴본 결과, 기체의 주입량, 용액의 주입량 증가는 열전달 성능 향상에 기여하며, 용액의 온도나 농도의 상승은 열전달 성능에 방해요소로 작용하였으며 흐름방향이 향류인 경우 열전달 성능에 향상이 있었다. 본 실험의 데이터를 이용하여 상관관계식을 유도하여 열전달에 대한 복잡한 관계를 일반화 하였다.

  • PDF

암모니아-물 흡수식 열교환 사이클의 운전 특성 (Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle)

  • 강인석;김남진;김종보
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.357-362
    • /
    • 2001
  • 충진농도, 냉매 팽창밸브 개도, 그리고 약용액의 유량 변화에 따른 벤치타입 암모니아-물 흡수식 열교환 사이클에 대한 실험을 수행한 결과 시스템의 충진농도가 증가할수록 냉방능력이 증가하였으며, 최적의 충진농도가 존재함을 알았다. 그리고 냉매 팽창 밸브의 개도는 응축기 출구의 직접적인 영향을 주고 있으며 최적의 과냉도가 0~4$^{\circ}C$임을 알았다. 또한 약용액의 유량이 증가시킬수록 증발압력과 강용액의 농도가 즐어들었으며, 냉방능력과 COP가 최대가 되는 최적의 약용액 유량이 존재하였다.

  • PDF