• Title/Summary/Keyword: 흡수선량 평가

Search Result 210, Processing Time 0.02 seconds

Evaluation of Radiation Exposure to Residents by Naturally Residing Radionuclides in the Soil of Korea (한국토양 내 천연 방사성핵종에 의한 거주민의 방사선피폭평가)

  • Kim, Jung-Hoon;Kim, Ah-Reum;Ko, Seong-Jin;Whang, Joo-Ho
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.219-224
    • /
    • 2009
  • We investigated the amounts of radiation exposure from $^{238}U$, $^{232}Th$, and $^{40}K$ which are three major radionuclides naturally residing in soil of the Korean peninsula. The experimental results showed that the concentrations of the radionuclides were 15.77$\pm$7.27, 290.05$\pm$73.92 and 750.30$\pm$165.38 Bq/kg respectively. The absorbed dose rate based on the measured concentrations was 213.76$\pm$46.37 nGy/hr, while the spatial gamma absorbed dose rate measured in the same region was 123.90$\pm$19.18 nGy/hr. The effective dose rate was 0.26 mSv/yr, which is significantly higher than the world average effective dose rate 0.07 mSv/yr provided by the UNSCEAR.

  • PDF

Dose assessment according to Differences in the Content of Iodine in Contrast Media used in Interventional Procedure (중재적 시술에 사용하는 조영제의 요오드(53I) 함유량 차이에 따른 피폭선량 평가)

  • Bak, Hyeok;Jeon, Ju-Seob;Kim, Yong-Wan;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.337-345
    • /
    • 2014
  • The purpose of this study is to evaluate exposure dose and absorbability according to differences in the content of iodine in contrast media used in interventional procedure and angiography. There were 7 levels of iodine content as 240, 270, 300, 320, 350, 370, and 400 I $mg/m{\ell}$. The higher iodine content was, the more elevated exposure dose and absorbability were. The output dose was about 8.5% from iodine content with 350I $mg/m{\ell}$ higher than that with 270 I $mg/m{\ell}$ in TACE. These results mean that contrast media can have an effect on patient's exposure dose and high iodine content contrast media results in elevation of patient's exposure dose.

Radiation Protective Effect of the Thyroid Gland Using Bolus Protector in the Dental Cone Beam Computed Tomography (치과 콘빔 전산화단층검사 시 보루스 차폐체를 이용한 갑상선의 방사선 차폐효과)

  • Lee, Tae Hui;Jeong, Seung Hun;Kim, Dong Woo;Park, Myeong Hwan;Kim, Tae-Hyung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.459-464
    • /
    • 2019
  • In order to minimize the radiation exposure dose of the thyroid site at dental cone-beam computer tomography, a protector using a Bolus was prepared, and the radiation shielding effect and the appropriateness of the image were evaluated. Using a dental cone-beam computed tomography (CBCT), a glass dosimeter was attached to the left and right sides of the thyroid for a dental radiation phantom, and the radiation dose was measured. The absorbed dose for each shield was measured by another method to 10 mm, 20 mm, and 30 mm-thickness, respectively. Eight evaluators evaluated whether or not the medical image is appropriate. When using a 30 mm Bolus shield at the left thyroid site, the resulting value is reduced by an average of $342.67{\mu}Gy$ by 20.7% from the average value of $431.22{\mu}Gy$ measured without using a Bolus shield, the right thyroid site In the case of using 30 mm Bolus shield, it showed a dose reduction effect of 21.9% with an average of $424.56{\mu}Gy$. The adequacy of the medical image was judged to be usable by both evaluators. In conclusion, the dental cone-beam computerized tomography can be used as a useful shielding material because it has a radiation shielding effect and it is possible to treat the diagnosis of the bolus protector in the thyroid without any obstruction shade in order to minimize the radiation dose.

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.

Depth Dose Distribution of Proton Beams by Variation of Tumor Density using Geant4 (Geant4 전산모사를 이용한 종양의 밀도 변화에 따른 양성자의 선량 분포)

  • Kim, You-Me;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.771-779
    • /
    • 2021
  • It is necessary to overlap several peaks to form spread out Bragg peak (SOBP) in order to cover the tumor volume because a mono-energetic proton beam forms a narrow Bragg peak. The tumor density has been considered as a brain tissue and then the absorbed dose of the tumor is calculated using Monte Carlo simulations. However, densities of tumors were not a constant. In this study, the SOBP of proton beams was calculated according to changing density of tumors by using Geant4. Tumors were selected as 10 mm and 20 mm width which were the treatment range in the brain phantom. The energies and relative weights of the proton beams were calculated using mathematical formula to form the SOBP suitable for the location and size of the tumor. As the density of the tumor was increased, the 95% modulation range and the practical range were decreased, and average absorbed dose in the 95% modulation range was increased. The change of the tumor density affects the dose distribution of the proton beams, which results in short SOBP within the tumor volume. The consideration of the tumor density affects the determination of the range, so that the margin of the treatment volume can be minimized, and the advantages of proton therapy can be maximized.

The Study of Dose Distribution according to the Using Linac and Tomotherapy on Total Lymphnode Irradiation (선형가속기와 토모치료기를 이용한 전림프계의 방사선 치료시 선량분포에 관한 연구)

  • Kim, Youngjae;Seol, Gwanguk
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.285-291
    • /
    • 2013
  • In this study, compare and analyze the dose distribution and availability of radiation therapy when using a different devices to TNI(Total Lymphnodal Irradiation). Test subjects(patients) are 15 people(Male 7, Female 8). Acquire CT Simulation images of the 15 people using Somatom Sansation Open 16 channel and then acquired images was transferred to each treatment planning system Pinnacle Ver 8.0 and Tomotherapy Planning System and separate the tumor tissue and normal tissues(whole lung, spinal cord, Rt kidney, Lt kidney). Tumor prescription dose was set to 750 cGy. and then Compare the Dose Compatibility, Normal Tissue's Absorbed Dose, Dose Distribution and DVH. Statistical analysis was performed SPSS Ver. 18.0 by paired sample Assay. The absorbed dose in the tumor tissue was $751.0{\pm}4.7cGy$ in tomotherapy planning, $746.9{\pm}14.1cGy$ in linac. Tomotherapy's absorbed dose in the tumor was more appropriate than linac. and These values are not statistically significant(p>0.05). Tomotherapy plan's absorbed dose in the normal tissues were less than linac's plan. This value was statistically significant(p<0.05) excepted of whole lung. In DVH, appropriated on tumor and normal tissues in tomotherapy and linac but tomotherapy's TER was better than linac. Namely, a result of Absorbed dose in tumor and normal tissue, Dose distribution pattern, DVH, Both radiation therapy devices were appropriated in radiation therapy on TER. The Linac has a short treatment time(about 15-20 min) and open space on treatment time. It cause infant and pediatric patients to receiving uncomfortable treatment. So, In this case, it will be fine that Linac based therapy was restricted use. and if the patient was cooperative, it will be show a better prognosis that Tomotherapy using Radiation Therapy.

Microbiological, physicochemical, and organoleptic evaluation of fresh-cut vegetables irradiated using X-rays (엑스선 조사처리된 신선편의 채소류의 미생물학적, 이화학적, 관능적 품질 평가)

  • Moon, Byeong-Geum;Song, Beom-Seok;Park, Jong-Heum;Kim, Jae-Kyung;Park, Ha-Young;Kim, Dong-Ho;Son, Eun-Joo;Im, Don-Sun;Eun, Jong-Bang
    • Food Science and Preservation
    • /
    • v.24 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • Microbiological, physicochemical, and organoleptic properties of fresh-cut vegetables (FVs), carrots, green peppers, cherry tomatoes, and paprika after X-ray irradiation were evaluated to verify food quality suitable for the immune-depressed patients. Total concentrations of aerobic bacteria in non-irradiated samples, except for cherry tomatoes, were 1.63-3.34 log CFU/g. Irradiation dose exceed 0.4 kGy was used for carrots and green peppers whereas the sterilization dose of 0.2 kGy was used for both cherry tomatoes and paprika. A dose of 0.4 kGy was tentatively determined as the minimum allowable dose for sterilization of the FVs, based on $D_{10}$-values of X-ray irradiation (0.11-0.32 kGy) for Escherichia coli, Listeria monocytogenes, and Salmonella Typhimurium inoculated on the samples. With respect to the physiological properties, only hardness was significantly decreased as the absorbed dose increased; however, there were no significant differences in hardness of the sterilized samples using X-rays at 0.4 kGy compared with those of non-irradiated samples (p<0.05). Moreover, overall acceptance scores of the sterilized FVs were higher than 5.0 points on a 7-point scale, indicating a good organoleptic quality. In a survey on preference of hospitalized patients with cancer (n=50), the average scores for the sterilized FVs, except for carrots, were higher than 4.0 points. In conclusion, it is considered that the FVs, except for carrots, sterilized using X-rays at 0.4 kGy could be served to immune-depressed patients as hygienically safe foods with acceptable organoleptic properties.

Dose Characteristics of Total-Skin Electron-Beam Irradiation with Six-Dual Electron Fields (Six-Dual 전자선 조사면에 의한 전신 피부 조사의 선량 특성)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.337-345
    • /
    • 1998
  • Purpose : To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated Materials and Method : The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of target-skin distance (TSD) and full collimator size (35*35 $cm^2$ on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cm * 105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. Results : The full width at half maximum(FWHM) of dose profile was 130 cm in large field of 105*105 $cm^2$ The width of $100\pm10\%$ of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose unifomity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80$\%$ depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. Conclusion : The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within$\pm10\%$ difference except the protruding area of skin which needs a shield and deeply curvatured region of skin which needs boosting dose.

  • PDF

Potential Errors in Committed Effective Dose Due to the Assumption of a Single Intake Path in Interpretation of Bioassay Results (바이오어세이 결과 해석에서 단일 섭취경로 가정에 따르는 예탁유효선량의 잠재오차)

  • Lee, Jong-Il;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.135-140
    • /
    • 2006
  • Intakes of radionuclides through both inhalation and ingestion pathways may occur particularly in an incident involving unsealed radionuclides. If one assume only one intake path in this case, which is usual in routine monitoring, a significant error in the evaluated committed effective dose($E_{50}$) may result. In order to demonstrate the potential errors, variations of the resulting committed effective doses were analyzed for different fractions of the inhaled activities to the total intake of $^{241}Am$. Simulated bioassav measurements for the lungs, urine and feces were generated based on the biokinetic model and data of the radionuclide, 5 ${\mu}m$ AMAD and absorption type M for inhalation, for various inhalation fractions. The potential errors in $E_{50}$ due to the assumption of one intake path were in the range from -100% to as large as +34,000% when the bioassays were made 3 days after the intakes. Larger errors are expected when only the feces assay is applied while inhalation intake exists. A strategy which employs two types of bioassay was proposed to reduce the error caused by a misjudgement of the intake path.