Reliability Analysis of Composite Girder Designed by LRFD Method for Positive Flexure (하중저항계수설계법(LRFD)으로 설계된 강합성 거더의 휨에 대한 신뢰도해석)

  • Shin, Dong-Ku;Kim, Cheon-Yong;Paik, In-Yeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.539-546
    • /
    • 2006
  • The reliability analysis of simply-supported composite plate girder and box girder bridges under positive flexure is performed. The bridges are designed based on the AASHTO-LRFD specification. A performance function for flexural failure is expressed as a function of such random variables as flexural resistance of composite section and design moments due to permanent load and live load. For the flexural resistance, the statistical parameters obtained by analyzing over 16,000 samples of domestic structural steel products are used. Several different values of statistical parameters with the bias factor in the range of 0.95-1.05 and the coefficient of variation in the range of 0.15-0.25 are used for the live-load moment. Due to the lack of available domestic measured data on the dead load moment, the same values of statistical properties used in the calibration of AASHTO-LRFD are applied. The reliability indices for the composite plate girder and box girder bridges with various span lengths are calculated by applying the Rackwitz-Fiessler technique.

Flexural Strength of PHC Pile Reinforced with Infilled Concrete, Transverse and Longitudinal Reinforcements (내부충전 콘크리트와 횡보강 및 축방향 철근으로 보강된 PHC 말뚝의 휨강도)

  • Bang, Jin-Wook;Hyun, Jung-Hwan;Lee, Bang-Yeon;Lee, Seung-Soo;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • The pre-tensioned spun high strength concrete (PHC) pile has poor load carrying capacity in shear and flexure, while showing excellent axial load bearing capacity. The purpose of this study is to evaluate the flexural performance of the concrete-infilled composite PHC (ICP) pile which is the PHC pile reinforced with infilled concrete, transverse and longitudinal reinforcement for the improvement of shear and flexural load carrying capacity. The ICP pile specimen was designed to make allowable axial compression and bending moment higher load bearing capacity than those determined through the investigation of abutment design cases. The allowable axial compression and bending moment of the ICP pile was obtained using the program developed for calculating the axial compression - bending moment interaction. Then, ICP pile specimens were manufactured and flexural tests were performed. From the test results, it was found that the maximum bending moment of the ICP pile was approximately 45% higher than that of the PHC pile and the safety factor of ICP pile design was about 4.5 when the allowable bending moment was determined to be 25% of the flexural strength.

Basic Properties of Latex-Modified Concrete Using Fly-ash (플라이애쉬를 이용한 라텍스개질 콘크리즈의 기초물성 연구)

  • Hong, Chang-Woo;Jeong, won-Kyong;Kim, Kyong-jin;Yun, Kyong-ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.205-211
    • /
    • 2006
  • The purpose of this study was to evaluate the effects of fly-ash on strength development and durability of latex-modified concrete (LMC) and ordinary portland cement concrete (OPC). Main experimental variables were latex contents (0%, 10%, 15%) and fly-ash content (0, 10%, 20%, 30%). Air content and slump tests were performed to check the basic properties of fresh concretes, and compressive strength, flexural strength, rapid chloride ion permeability and chemical resistance were measured to analyze the basic properties of hardened concretes. The test results showed that air contents of LMC with fly ash decreased as fly-ash contents increased from 0% to 30%. Compressive and flexural strength developments of LMC with fly ash were quite similar to those of LMC without fly ash. However, the long-term flexural strength development of LMC with fly ash after 90 days were bigger than that of LMC without fly ash. Chloride ion permeability and chemical resistance decreased rapidly as the content of fly ash increased. Thus, fly ash could be used at LMC in order to reduce water permeability.

Design Comparison of Composite Girder Bridges Designed by ASD and LRFD Methods (허용응력설계법 및 하중저항계수설계법에 의한 강합성 거더교 설계결과 비교)

  • Cho, Eun-Young;Shin, Dong-Ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.447-456
    • /
    • 2009
  • The design comparison and flexural reliability analysis of continuous span composite plate girder bridges are performed. The girders are designed by the methods of allowable stress design (ASD) and load and resistance factor design (LRFD). For the LRFD design, the design specification under development mainly by KBRC, based on AASHTO-LRFD specification in case of steel structures, is applied with the newly proposed design live load which has been developed by analyzing domestic traffic statistics from highways and local roads. For the ASD based design, the current KHBDC code with DB-24 and DL-24 live loads is used. The longest span length for the 3-span continuous bridges with span arrangement ratio of 4:5:4 is assumed to be from 30 m to 80 m. The amount of steel, performance ratios, and governing design factors for the sections designed by the ASD and LRFD methods are compared. In the reliability analysis for the flexural failure of the sections designed by two methods, the statistical properties on flexural resistance based on the yield strength statistics for over 16,000 domestic structural steel samples are applied.

Estimation of The Basic Properties of Two-Lift Concrete Pavement to Apply Korea Condition (이층 포설 콘크리트 포장의 국내 적용을 위한 강섬유 보강 콘크리트 기초 물성평가)

  • Won, Hong-Sang;Ryu, Sung-Woo;Hong, Jong-Yong;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.12 no.1
    • /
    • pp.47-54
    • /
    • 2010
  • This study had a focus on investigating technical validity of Two-Lift Concrete Pavements which had never been constructed in Korea in order to olve the problem of existing concrete pavements. This study found out the application of Steel Fiber Reinforced Concrete (SFRC) which was one of ew techniques. Also, optimal steel fiber contents and pavement thickness were determined. This study also measured compressive strengths, lexural strengths, toughness indexes, tensile strengths and fatigue strengths to estimate the performance of SFRC of according to results of aboratory experiments, slumps and air contents of concrete specimens the standards satisfied and compressive strengths to open traffic. At bending ests, Toughness Index of SFRC increased but flexural strength didn’'t increase as compared with non-steel fiber concretes. And, energy absorption of SFRC was very good and SFRC showed improvement in freezing and thawing resistances. To complete this research, we will evaluate the pplication methods and performance of SFRC at field section.

An Experimental Study on the Mechanical Properties of Porous Concrete Using Coal Ash and Polymer (석회석 골재를 사용한 강섬유보강 포러스콘크리트의 강도특성에 관한 실험적 연구)

  • Lee, Byung-Jae;Park, Seong-Bum;Jang, Young-Il;Jeon, Heum-Jin;Lee, Taek-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.685-688
    • /
    • 2008
  • Concrete is strong on the compressive property, but weak on the tensile and flexural properties. To improve these problems, the reinforcing bar is used in concrete. But porous concrete with steel fiber has a weak point when exposed to air, because porous concrete has the vast continuous void on its inside and steel fiber is easily rusted by air. For these reasons, this study investigated the void ratio, compressive strength, bending strength and bending toughness as steel fiber mixing ratio and target void ratio. From test results, actual void ratio and strength properties increased as the mixing ratio of steel fiber increase. In case the mixing ratio of steel fiber over the fixed ratio, strength is decreased. And from the toughness evaluation, compared to the porous concrete which isn't mixed with steel fiber, the deflection variation efficiency is remarkably improved. Consequently we can confirm the possibility of porous concrete with steel fiber for the secondary product and pavement material to improve strength and bending resistance efficiency.

  • PDF

Flexural Behavior of Composite HSB I-Girders in Positive Moment (HSB 강합성거더 정모멘트부 휨거동)

  • Cho, Eun-Young;Shin, Dong-Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.377-388
    • /
    • 2010
  • The flexural behavior of composite HSB600 and HSB800 I-girders under a positive moment was investigated using the material non-linear moment-curvature analysis method. Three representative composite sections with different ductility properties were selected as the baseline sections in this study. Using these baseline sections, the moment-curvature program was verified by comparing the flexural strength and the moment-curvature curve obtained from the program with those obtained using the non-linear FE analysis of ABAQUS. In the FE analysis, the composite girders were modeled three-dimensionally with flanges, the web, and the concrete slab as thin shell elements, and initial imperfections and residual stresses were imposed on the FE model. In the moment-curvature and FE analyses, the 28-day compressive strength of the concrete slab was assumed to be 30-50 MPa, and the HSB600 and HSB800 steels were modeled as elasto-plastic strain-hardening materials, with the concrete as the CEB-FIP model. The effects of the ductility ratio of the composite girder, the type of steel, the compressive strength of the concrete deck, and the location of the plastic neutral axis on the flexural characteristics were analyzed.

Flexural Behavior of RC Beam After Completion of Electrochemical Chloride Extraction (전기화학적 염화물 추출 후 철근-콘크리트 보의 휨 거동)

  • Jung Wook Lee;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.484-492
    • /
    • 2023
  • The structural behaviour of concrete beam was examined by the three points bending test after the completion of the electrochemical chloride extraction (ECE), rather than bond strength mostly measured in previous studies. It was found that the flexural rigidity of concrete was lowered by the ECE, but the strength was enhanced in terms of the maximum load.The flexural rigidity, in the linear elastic range, was reduced by the loss of effective cross-section area. In fact, the inertia moment was substantially subjected to 70 % loss of the cross-section by the tensile strain at the condition of the failure. However, a lower rate of the inertia moment reduction was achieved by the ECE, implying the higher resistance to the cracking, but the higher risk of deformation.

Enhancement of Impact Resistance of Layered Steel Fiber Reinforced High Strength Concrete Beam (층 구조를 갖는 강섬유 보강 고강도 콘크리트 보의 충격저항성능 향상)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Lee, Jin-Young;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.369-379
    • /
    • 2012
  • The collapse of concrete structures by extreme loads such as impact, explosion, and blast from terrorist attacks causes severe property damage and human casualties. Concrete has excellent impact resistance to such extreme loads in comparison with other construction materials. Nevertheless, existing concrete structures designed without consideration of the impact or blast load with high strain rate are endangered by those unexpected extreme loads. In this study, to improve the impact resistance, the static and impact behaviors of concrete beams caste with steel fiber reinforced concrete (SFRC) with 0~1.5% (by volume) of 30 mm long hooked steel fibers were assessed. Test results indicated that the static and impact resistances, flexural strength, ductility, etc., were significantly increased when higher steel fiber volume fraction was applied. In the case of the layered concrete (LC) beams including greater steel fiber volume fraction in the tensile zone, the higher static and impact resistances were achieved than those of the normal steel fiber reinforced concrete beam with an equivalent steel fiber volume fraction. The impact test results were also compared with the analysis results obtained from the single degree of freedom (SDOF) system anaysis considering non-linear material behaviors of steel fiber reinforced concrete. The analysis results from SDOF system showed good agreement with the experimental maximum deflections.

A Study on Method of Evaluation for Deck Pavement (교면포장의 평가 방법 고찰)

  • Jo, Shin Haeng;Jo, Nam June;Jang, Jung Soon;Baek, Yu Jin;Kim, Nak Seok
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.86-86
    • /
    • 2011
  • 토목 기술의 발달로 장대교량이 증가함에 따라 교면 포장도 더 심각한 진동 및 충격, 기상조건에 노출되게 된다. 교면 포장은 차량의 주행의 편리성뿐 아니라 교량 구조물을 보호해야 하는 역할도 함께 수행하기 때문에 일반 토공부의 포장과 다른 성능을 필요로 한다. 교면 포장의 특수함을 감안하여 교면 포장의 품질을 평가하고, 설계와 적용시 반영 한다면 교량의 내구 연한 및 시공, 유지관리 비용을 절감 할 수 있을 것이다. 본 논문에서는 교면 포장에 요구되는 성능을 조사하고, 교면 포장 특히, 장대 교량 적용시 교면 포장의 성능 평가를 위한 평가 방법을 고찰하였다. 교면 포장의 가장 큰 구조적 특징은 교량의 진동과 휨에 의해 포장이 받게 되는 휨응력이다. 특히 교량의 장경간화에 따라 더 큰 진동과 변형을 경험하게 되는 교면 포장은 그에 따른 충분한 휨 추종성과 피로 저항성을 확보하여야 한다. 기존 토공부 포장에서는 실험이 간단한 원통형 공시체를 이용한 간접인장강도 모드의 실험으로 피로 성능을 평가하였으나, 교면 포장은 실제 거동 특성과 유사한 빔 피로 시험 모드가 보다 신뢰성이 높을 것으로 판단된다. 빔 피로시험 모드로는 3점, 4점, 5점 휨 피로 시험 모드가 있으며, 각각의 모드는 지지점의 개수, 재하점의 개수에 따라 다른 거동 특성을 평가 할 수 있다. 최근 개발된 5점 휨 시험의 경우 교량에서 발생하는 부(-)모멘트를 모사할 수 있어 보다 현실적인 검증이 가능할 것으로 예상된다. 이 외에도 실제 크기 모형을 이용하여 윤하중을 가하는 Full-scale 모델의 경우 비용과 시간이 많이 소요되는 단점이 있으나 가장 신뢰성이 높은 방법이라고 할 수 있다. 교면 포장은 교량구조부로 수분이 침투되는 것을 막아주는 역할을 하여야 하며, 특히 해상 교량의 경우의 염분과 겨울철 사용되는 제빙화학제는 콘크리트의 열화와 강구조물의 부식을 발생시키므로 교면 포장의 방수 성능 검토는 매우 중요한 역할을 한다. 일반 토공부 포장과 달리 교면 포장은 하부층이 대기에 노출되어 있기 때문에 겨울철에 더 낮은 온도로 포장체의 온도가 내려가게 되고, 온도가 떨어진 포장층은 스티프니스가 증감함에 따라 저온 균열의 발생확율이 높아지며, 휨추종성도 나빠질 가능성이 높다. 따라서 저온에서의 균열 저항성 및 스티프니스를 평가하는 것은 교면 포장 재료의 중요한 인자 중 하나이다. 포장과 포장 하부층의 접착은 포장층의 일체화된 거동을 할 수 있게 하기 때문에 내구성 향상에 중요하다. 특히 교량과 같이 진동과 변형이 많은 경우에 있어 포장 접착층의 성능은 포장과 교량 구조물의 파손에 더 큰 영향을 미치게 된다. 접착성능은 실내에서의 직접인장모드와 전단접착강도 시험 모드의 실험이 있으며, 현장에서 측정하는 Pull-off 실험 등이 있다. 최근에 교통량과 중차량의 증가와 더불어 교량이 장경간화 되어 가면서 평가방법과 기준을 과거보다 엄격하게 할 필요성이 있다. 하지만 현실은 교면포장에 대한 시방규정이 모호하기 때문에 본 논문에서 제시한 국내외의 다양한 평가방법을 통해 적절한 교면포장의 성능을 평가하고 교면포장의 거동특성에 대한 이해를 함으로써 보다 발전된 교량기술을 확보할 수 있을 것이다.

  • PDF