• Title/Summary/Keyword: 후 컬럼 동위원소희석법

Search Result 7, Processing Time 0.023 seconds

Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS (후 컬럼 동위원소 희석법을 적용한 HPLC-ICP/MS에서의 정량분석에서 내부 표준물을 이용한 정확도와 정밀도의 개선연구)

  • Joo, Mingyu;Park, Myungsun;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.140-146
    • /
    • 2014
  • An internal standard was used in PCID (post column isotope dilution) to improve the accuracy and precision in quantification of various chemical species. The error occurring in the column was the largest in HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry) when PCID and other traditional quantification methods were compared with each other. Internal standard was effective in correcting the loss of sample in the column to improve accuracy and precision. When applied to SeMet, using MeSecys or $Se^{4+}$ as an internal standard, relative errors were reduced from 31% and 13% to less than 1%, while standard deviations were reduced from 5.1% and 6.9% to 1.5% and 0.2%, respectively. Positive aspects of using an internal standard in PCID were compared with other quantitative techniques and discussed in detail.

A short study of uncertainty for post column isotope dilution method in HPLC-ICP/MS (HPLC-ICP/MS에서 후 컬럼 동위원소 희석법의 기초적인 불확도 연구)

  • Joo, Mingyu;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.269-276
    • /
    • 2014
  • A short study for the uncertainty of post column isotope dilution method has been performed for the analysis of Selenomethionine in HPLC-ICP/MS. Major error sources studied were concentration and the flow rate of Se isotope solution, atomic weights of Se in spike and sample, and isotope ratio measured for the spiked sample. Uncertainties were obtained for each factor and the contribution for the total concentration uncertainty was 54.4% and 0.61%, 0.0072% and 0.018%, and 45.0%, respectively. The biggest contribution factor was concentration of the spike solution and the second was the isotopic ratio measured for the spiked sample solution. The mass flow rate of spike and atomic weights did not show much contribution. The calculated total uncertainty was $1.46ng{\cdot}g^{-1}$ for the standard SeMet ($126.30ng{\cdot}g^{-1}$). The experimental result was $127.09{\pm}1.46ng{\cdot}g^{-1}$ and the relative uncertainty was 1.20%.

Analyzing Co-planar PCBs in Food by HRGC/HRMS with Isotopic Dilution Method (동위원소희석법 HRGC/HRMS에 의한 식품 중 Co-planar PCBs 분석)

  • Choi, Dongmi;Suh, Junghyuck;Kim, Minjung;Hong, Mooki;Kim, Changmin;Song, Insang
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.325-332
    • /
    • 2003
  • To analyze co-planar PCBs in food, the isotopic dilution method by high resolution gas chromatography/high resolution mass spectrometry was applied. Among 209 PCB congeners, 12 congeners (#77, #81, #126, #169, #105, #114, #118, #123, #156, #157, #167 and #189) were chosen as target compounds that were toxic congeners re-assessed by WHO in 1998. Milk and milk products including cheese and butter were collected as food samples. Samples were homogenized, spiked with the known amount of the standard mixture and extracted. After extraction, extracts were cleaned up by sulfuric acid impregnated silica gel, purified on silica gel and alumina column chromatography and then analyzed by HRGC/HRMS. As results, the overall recoveries were ranged from 83% to 106% and the limit of detection was about 0.1 pg/g at signal/noise>3. Levels of targets in the selected food samples were 0.001~0.107 pgWHO-TEQ/g.

Quantification of seleno proteins in Korean blood serum using solid phase extraction and affinity chromatography-inductively coupled plasma/mass spectrometry (고체상 추출과 친화 크로마토 그라피-유도결합 플라즈마 질량분석법을 이용한 한국인 혈청에서의 셀레노 단백질 정량)

  • Ahn, Ji-Yun;Kwon, Hyo-Sik;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.92-99
    • /
    • 2014
  • Interferences were removed using anion exchange solid phase extraction (AE SPE) in quantification of selenoproteins in Korean human blood serum with affinity high performance liquid chromatography (AF HPLC)-inductively coupled plasma/mass spectrometry (ICP/MS). The average selenium level obtained for healthy Koreans was $94.3{\pm}2.3ngg^{-1}$ using isotope dilution method. AE SPE was coupled to AF column to separate 3 selenoproteins, glutathione peroxidase GPx, selenoprotein SelP, and selenoalbumin SeAlb. Post column isotope dilution was employed to quantify the proteins. The certified reference material of human blood serum BCR-637 was analyzed to give total selenoprotein concentration of $85.4{\pm}3.4ngg^{-1}$, which agreed well with the reference value of $81{\pm}7ngg^{-1}$. The pooled concentration of GPx, SelP, and SeAlb from healthy Koreans (n=20) was $12.1{\pm}1.4ngg^{-1}$, $57.2{\pm}2.0ngg^{-1}$, and $20.0{\pm}1.9ngg^{-1}$, respectively. The sum of selenoproteins is $89.3ngg^{-1}$, which is about the same as the total selenium concentration of $94.3ngg^{-1}$. The fact suggests that selenium in blood serum is mostly consisted of selenoproteins. After the removal of interference, GPx showed a significant decrease (more than 50%) from $25.0ngg^{-1}$ to $12.1ngg^{-1}$. It was identified that the interference in blood serum was mostly from GPx and the use of AE SPE was proven to be efficient in eliminating Cl and Br that cause interference to GPx.

Analysis of selenoaminoacids and selenoproteins in blood serum of sows fed by selenium fortified feed (셀레늄강화 사료를 먹인 모돈 혈청에서의 셀레노아미노산 및 셀레노단백질 분석)

  • Park, Myungsoon;Lee, Sung Hoon;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.196-203
    • /
    • 2015
  • Selenium species (inorganic selenium, selenoaminoacids, and selenoproteins) were analyzed using anion exchange and affinity chromatography, which were connected to ICP/MS for the blood serum of sows fed by seleniumfortified feed. The Anion Exchange PRP X-100 column was used for the analysis of inorganic selenium (Se4+ and Se6+) and selenoaminoacids. The HEP column was used to separate SelP from GPx+SeAlb in selenoproteins. A quantitative analysis was performed using the post-column isotope dilution technique. The lactating sows were divided into three groups and fed by selenium fortified feed (organic 0.3 mg/kg, 0.6 mg/kg and inorganic 0.6 mg/kg) for four weeks. The test groups showed increases in selenoaminoacids compared with the control group, except the inorganic feed group. There was no significant difference between the organic feed groups. All test groups showed increases in selenoproteins. In particular, SelP showed a large increase that was 1.5 times higher than the other proteins.

Quantitative analysis of selenium species in sea food using solid phase extraction and HPLC-ICP/MS (해산물 시료에서 solid-phase extraction 및 HPLC-ICP/MS를 이용한 셀레늄 화학종의 정량분석)

  • Kim, Eunju;Joo, Minkyu;Kwon, Hyosik;Pak, Yongnam
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.307-314
    • /
    • 2013
  • Selenium exists in various forms of chemical species. The activity and bioavailability is strongly dependent on its chemical form and concentration. Consequently the information on each selenium species and its concentration must be exactly determined for the food we take in. In this study, selenium species in seafood were separated and quantified by RP (reversed phase) HPLC (high performance liquid chromatography) coupled with ICP-MS (inductively coupled plasma mass spectrometry) using post-column isotope dilution. $^{79}Br$, which interferes on $^{80}Se$, has mostly been removed by solid phase extraction and then mathematical correction has been applied for the more accurate correction. The experimental result for CRM (certified reference material) DOLT-4 agreed well with the certified value but each selenium species could not be compared. SeCys (selenocysteine) and SeMet (selenomethionine) were the major species detected in seafood such as belt fish, spanish mackerel, and squid that have been serving as Korean diet. The concentrations found in Korean sea food for SeCys and SeMet were in the range of 0-661.6 mg/kg and 137.3-462.7 mg/kg, respectively.