Browse > Article
http://dx.doi.org/10.5806/AST.2014.27.6.269

A short study of uncertainty for post column isotope dilution method in HPLC-ICP/MS  

Joo, Mingyu (Department of Chemistry Education, Korea National University of Education)
Pak, Yong-Nam (Department of Chemistry Education, Korea National University of Education)
Publication Information
Analytical Science and Technology / v.27, no.6, 2014 , pp. 269-276 More about this Journal
Abstract
A short study for the uncertainty of post column isotope dilution method has been performed for the analysis of Selenomethionine in HPLC-ICP/MS. Major error sources studied were concentration and the flow rate of Se isotope solution, atomic weights of Se in spike and sample, and isotope ratio measured for the spiked sample. Uncertainties were obtained for each factor and the contribution for the total concentration uncertainty was 54.4% and 0.61%, 0.0072% and 0.018%, and 45.0%, respectively. The biggest contribution factor was concentration of the spike solution and the second was the isotopic ratio measured for the spiked sample solution. The mass flow rate of spike and atomic weights did not show much contribution. The calculated total uncertainty was $1.46ng{\cdot}g^{-1}$ for the standard SeMet ($126.30ng{\cdot}g^{-1}$). The experimental result was $127.09{\pm}1.46ng{\cdot}g^{-1}$ and the relative uncertainty was 1.20%.
Keywords
species unspecific isotope dilution; uncertainty; error calculation; HPLC-ICP/MS;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 L. Rottmann and K. G. Heumann, Fresenius J. Anal. Chem., 350, 221-228 (1994).   DOI
2 C. Swart, O. Rienitz and D. Schiel, Talanta, 83, 1544-1551 (2011).   DOI   ScienceOn
3 P. Rodriguez-Gonzalez, J. M. Marchante-Gayon, J. I. Garcia-Alonso and A. Sanz-Medel, Spectrochim. Acta B, 60, 151-207 (2005).   DOI   ScienceOn
4 L. Hinojosa Reyes, J. M. Marchante Gayon, J. I. Garcia Alonse and A. Sanz Medel., J. Anal. At. Spectrom., 18, 11-21 (2003).   DOI   ScienceOn
5 M. F. Gine and A. P. Packer, J. Braz. Chem. Soc., 21(4), 575-589 (2010).   DOI   ScienceOn
6 P. C. Uden, Anal. Bioanal. Chem., 373, 422-434 (2002).   DOI   ScienceOn
7 M. E. Del Castillo-Busto, M. Montes-Bayon and A. Sanz-Medel, Anal. Chem., 78, 8218-8225 (2006).   DOI   ScienceOn
8 J. C. Woo, Anal. Sci. Technol., 13(4), 1-13 (2000).
9 J. C. Woo, S. H, Oh, B. M. Kim, H. K. Bae, K. S. Kim and Y. D. Kim, Anal. Sci. Technol., 18(6), 475-482 (2005).
10 Korea Laboratory Accreditation Scheme (KOLAS), 'Evaluation of measurement data Guide to the expression of uncertainty in measurement', Republic of Korea, 2012.
11 ISO/IEC, 'General requirements for the competence of testing and calibration laboratories', 17025 second edition, 2005.
12 H. Y. Jang, H. Min, J. Lee and Y. N. Pak, Anal. Sci. Technol., 26(3), 182-189 (2013).   DOI   ScienceOn
13 J. Jeong, J. Lee, and Y. N. Pak, Bull. Korean Chem. Soc., 34(12), 3817-3824 (2013).   DOI   ScienceOn
14 E. Kim, M. Joo, H. Kwon and Y. Pak, Anal. Sci. Technol., 26(5), 307-314 (2013).   DOI   ScienceOn
15 C. Swart, O. Rienitz and D. Schiel, Anal. and Bioanal. Chem., 401(6), 2025-2031 (2011).   DOI   ScienceOn
16 L. Rottmann and K. G. Heumann, Fresenius J. Anal. Chem., 350, 221-235 (1994).   DOI