• Title/Summary/Keyword: 환자 선량

Search Result 1,412, Processing Time 0.023 seconds

A Multi Resolution Based Guided Filter Using Fuzzy Logic for X-Ray Medical Images (방사선 의료영상 잡음제거를 위한 퍼지논리 활용 다해상도 기반 유도필터)

  • Ko, Seung-Hyun;Pant, Suresh Raj;Lee, Joonwhoan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.4
    • /
    • pp.372-378
    • /
    • 2014
  • Noise in biomedical X-ray image degrades the quality so that it might causes to decrease the accuracy of diagnosis. Especially the noise reduction techniques is quite essential for low-dose biomedical X-ray images obtained from low radiation power in order to protect patients, because their noise level is usually high to well discriminate objects. This paper proposes an efficient method to remove the noise in low-dose X-ray images while preserving the edges with diverse resolutions. In the proposed method, a noisy image is at first decomposed into several images with different resolutions in pyramidal representation, then the stable map of edge confidence is obtained from each of analyzed image using a fuzzy logic-based edge detector. This map is used to adaptively determine the parameter for guided filters, which eliminate the noise while preserving edges in the corresponding image. The filtered images in the pyramid are extended and synthesized into a resulted image using interpolation technique. The superiority of proposed method compared to the median, bilateral, and guided filters has been experimentally shown in terms of noise removal and edge preserving properties.

Construction and Performance Evaluation of Digital Radiographic System (이동형 디지털 X선 촬영장치의 구축 및 성능평가)

  • Cho, Hyo-Min;Nam, So-Ra;Lee, Chang-Lae;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

  • PDF

Effect of Glucose Level on Brain FDG-PET Images (FDG를 이용한 Brain PET에서 Glucose Level이 영상에 미치는 영향)

  • Kim, In-Yeong;Lee, Yong-ki;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.275-280
    • /
    • 2017
  • In addition to tumors, normal tissues, such as the brain and myocardium can intake $^{18}F$-FDG, and the amount of $^{18}F$-FDG intake by normal tissues can be altered by the surrounding environment. Therefore, a process is necessary during which the contrasts of the tumor and normal tissues can be enhanced. Thus, this study examines the effects of glucose levels on FDG PET images of brain tissues, which features high glucose activity at all times, in small animals. Micro PET scan was performed on fourteen mice after injecting $^{18}F$-FDG. The images were compared in relation to fasting. The findings showed that the mean SUV value w as 0.84 higher in fasted mice than in non-fasted mice. During observation, the images from non-fasted mice showed high accumulation in organs other than the brain with increased surrounding noise. In addition, compared to the non-fasted mice, the fasted mice showed higher early intake and curve increase. The findings of this study suggest that fasting is important in assessing brain functions in brain PET using $^{18}F$-FDG. Additional studies to investigate whether caffeine levels and other preprocessing items have an impact on the acquired images would contribute to reducing radiation exposure in patients.

Evaluation of MTF Image by Target/Filter Combined of X-ray Tube Using Mammography (유방촬영용 X선관 target/filter 조합에 따른 MTF영상평가에 관한 고찰)

  • Yang, Han-Jun;Joo, Mi-Hwa;Ko, Sin-Kwan
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.113-119
    • /
    • 2007
  • It is important to consider the contrast of object in Mammography because an absorption gap between tissues of body and breast in breast is low. This study is to evaluate MTF image with resolution chart according to change of combination of target and filter. The results were as follows : 1. There were significant differences in X-ray energy according to combination of filter(Mo/Mo, Mo/Rh. Mo/Al, Rh/Rh, Rh/Al) and acrylic thickness(2 cm, 3 cm, 4 cm). 2. The value of lp/mm on MTF to 0.5 showed that the sharpness in MTF curve was 2.4 compared to Mo/Mo and 2cm acryl, 2.63 in Mo/Rh and 4 cm acryl, and 2.9 in Rh/Rh and 6cm acryl. 3. The value of lp/mm on MTF showed that the resolution in MTF curve was 6.0 compared to Mo/Mo and 2 cm acryl, 4.60 in Rh/Al and 4cm acryl, and 6.03 in Rh/Al and 6 cm acryl. 4. The value of MTF on 2.5 lp/mm distinguishable visually was 0.48 compared to Mo/Mo and 2 cm acryl, 0.53 in Mo/Rh and 4cm acryl, and 0.59 in Rh/Rh and 6cm acryl. 5. For the evaluation of an image of the mammo-phantom, the score of Mo/Mo was 12 points, Mo/Rh 11, Rh/Rh 10.5, Mo/Al 10, Rh/Al 9.0, respectively.

  • PDF

Report for Spreading Culture of Medical Radiation Safety in Korea : Mainly the Activities of the Korean Alliance for Radiation Safety and Culture in Medicine(KARSM) (국내 의료 방사선 안전문화 활동 현황 : 의료방사선안전문화연합회 중심으로)

  • Yoon, Yong-Su;Kim, Jung-Min;Kim, Hyun-Ji;Choi, In-Seok;Sung, Dong-Wook;Do, Kyung-Hyun;Jung, Seung-Eun;Kim, Hyung-Soo
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.193-200
    • /
    • 2013
  • There are many concerns about radiation exposure in Korea after Fukushima Nuclear Plant Accident on 2011 in Japan. As some isotope materials are detected in Korea, people get worried about the radioactive material. In addition, the mass media create an air of anxiety that jump on the people's fear instead of scientific approach. Therefore, for curbing this flow, health, medical institute from the world provide a variety of information about medical radiation safety and hold the campaign which can give people the image that medical radiation is safe. At this, the Korean Food and Drug Administration(KFDA) suggested that make the alliance of medical radiation safety and culture on August, 2011. Seven societies and institutions related medical radiation started to research and advertise the culture of medical radiation safety in Korea. In this report, mainly introduce the activities of the Korean Alliance for Radiation Safety and Culture in Medicine(KARSM) for spreading culture of medical radiation safety from 2011 to 2012.

Optimal Localization through DSA Distortion Correction for SRS

  • Shin, Dong-Hoon;Suh, Tae-Suk;Huh, Soon-Nyung;Son, Byung-Chul;Lee, Hyung-Koo;Choe, Bo-Young;Shinn, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.39-47
    • /
    • 2000
  • In Stereotactic Radiosurgery (SRS), there are three imaging methods of target localization, such as digital subtraction Angiography (DSA), computed tomography (CT), magnetic resonance imaging (MRI). Especially, DSA and MR images have a distortion effect generated by each modality. In this research, image properties of DSA were studied. A first essential condition in SRS is an accurate information of target locations, since high dose used to treat a patient may give a complication on critical organ and normal tissue. Hut previous localization program did not consider distortion effect which was caused by image intensifier (II) of DSA. A neurosurgeon could not have an accurate information of target locations to operate a patient. In this research, through distortion correction, we tried to calculate accurate target locations. We made a grid phantom to correct distortion, and a target phantom to evaluate localization algorithm. The grid phantom was set on the front of II, and DSA images were obtained. Distortion correction methods consist of two parts: 1. Bilinear transform for geometrical correction and bilinear interpolation for gray level correction. 2. Automatic detection method for calculating locations of grid crosses, fiducial markers, and target balls. Distortion was corrected by applying bilinear transform and bilinear interpolation to anterior-posterior and left-right image, and locations of target and fiducial markers were calculated by the program developed in this study. Localization errors were estimated by comparing target locations calculated in DSA images with absolute locations of target phantom. In the result, the error in average with and without distortion correction is $\pm$0.34 mm and $\pm$0.41 mm respectively. In conclusion, it could be verified that our localization algorithm has an improved accuracy and acceptability to patient treatment.

  • PDF

Study on the Development and Application of Image Viewer System (Image Viewer System의 개발 및 적용에 관한 고찰)

  • Yang, Oh-Nam;Seo, In-Ki;Hong, Dong-Ki;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.67-73
    • /
    • 2006
  • Purpose: The number of patients receiving radiotherapy has increased every year and will keep increasing in the future. Therefore, the technique of radiotherapy is developing from day to day, as a result of it, the quantities of image and data used for radiotherapy are also considerably increasing. Therefore, there have been many difficulties in storing, keeping and managing them. Then, we developed and applied this system for improving complicated work process as well as solving these problems with the collaboration Medical Information Team. Materials and Methods: We exported its image at R & V (Record and Verify: Varis vision, Varian, USA) system and planning system after giving some code to be able to access from management system(RO) for department of radiation oncology to PACS. And, we programmed their information by using necessary information among many information included in DICOM head. Results: All images and data generated by our working environment (Simulation CT, L-gram image and internal body structure, DRR, does distribution )were realized at PACS and it became to be possible for clear image to be printed from any computer in department of radiation oncology. Conclusion: It was inevitable to use film during radiotherapy for patients in the past, however, due to the development of this system, film-less system became to be possible. Therefore, the darkroom space and its management cost in relation to the development process disappeared and it became to be unnecessary for spending tangible and intangible financial expense including human resources, time needed for finding film storing space and film and purchasing separate storing equipment for storing images. Finally, we think this system would be very helpful to handle ail complicated processes for radiotherapy and increasing efficiency of overall working conditions.

  • PDF

The Recent Trend of the National and International Standard of Manufacturing Quality Control for Diagnostic X-ray Equipment (진단용엑스선장치 제조품질관리에 관한 국내.외 규격의 동향)

  • Choi, In-Seok;Kim, Jung-Min;Jeong, Hoi-Woun;Min, Jung-Whan;Lee, In-Su
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.1-15
    • /
    • 2009
  • Newly published IEC 60601-1-3 ; 2008 2nd Edition has two important meanings. First, Radiation Quality and Dose should make sure for safety of patient and staff in manufacturing diagnostic X-ray equipment. Second, it should be minimized of Leakage Radiation, Residual Radiation, and Stray Radiation. The requirement to make enactment or revision of national standard for diagnostic X-ray Equipment is as follows : 1. It should be adjusted the new standard to the recent IEC Publication under the consideration of the Korea medical circumstances. 2. For focus to the Radiation Safety, IEC 60601-1-3 (General requirements for radiation protection in diagnostic X-ray equipment) could be applied to the new regulation. It should be compact sentence. 3. A sudden Notification change should not be desired. It needs a enough time to make easy the circumstances.

  • PDF

Current Status of Imaging Physics & Instrumentation In Nuclear Medicine (핵의학 영상 물리 및 기기의 최신 동향)

  • Kim, Hee-Joung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.83-87
    • /
    • 2008
  • Diagnostic and functional imaging device have been developed independently. The recognition that combining of these two devices can provide better diagnostic outcomes by fusing anatomical and functional images. The representative examples of combining devices would be PET/CT and SPECT/CT. Development and their applications of animal imaging and instrumentation have been very active, as new drug development with advanced imaging device has been increased. The development of advanced imaging device resulted in researching and developing for detector technology and imaging systems. It also contributed to develop a new software, reconstruction algorithm, correction methods for physical factors, image quantitation, computer simulation, kinetic modeling, dosimetry, and correction for motion artifacts. Recently, development of MRI and PET by combining them together was reported. True integration of MRI and PET has been making the progress and their results were reported. The recent status of imaging and instrumentation in nuclear medicine is reported in this paper.

A noble Sample-and-Hold Circuit using A Micro-Inductor To Improve The Contrast Resolution of X-ray CMOS Image Sensors (X-ray CMOS 영상 센서의 대조 해상도 향상을 위해 Micro-inductor를 적용한 새로운 Sample-and-Hold 회로)

  • Lee, Dae-Hee;Cho, Gyu-Seong;Kang, Dong-Uk;Kim, Myung-Soo;Cho, Min-Sik;Yoo, Hyun-Jun;Kim, Ye-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.4
    • /
    • pp.7-14
    • /
    • 2012
  • A image quality is limited by a sample-and-hold circuit of the X-ray CMOS image sensor even though simple mos switch or bootstrapped clock circuit are used to get high quality sampled signal. Because distortion of sampled signal is produced by the charge injection from sample-and-hold circuit even using bootstrapped. This paper presents the 3D micro-inductor design methode in the CMOS process. Using this methode, it is possible to increase the ENOB (effective number of bit) through the use of micro-inductor which is calculated and designed in standard CMOS process in this paper. The ENOB is improved 0.7 bit from 17.64 bit to 18.34 bit without any circuit just by optimized inductor value resulting in verified simulation result. Because of this feature, micro-inductor methode suggested in this paper is able to adapt a mamography that is needed high resolution so that it help to decrease patients dose amount.