• Title/Summary/Keyword: 환기부하

Search Result 98, Processing Time 0.032 seconds

Aerobic Capacity and Ventilatory Response During Incremental Exercise in Elite High School Cyclist (점진부하 운동에서 중고교 엘리트 사이클 선수들의 유산소능력과 폐환기 반응)

  • Lee, Dae-Taek;Bae, Yoon-Jung
    • Journal of Life Science
    • /
    • v.20 no.3
    • /
    • pp.437-443
    • /
    • 2010
  • This study was designed to examine the aerobic capacity and ventilatory response during an incremental exercise in elite high school cyclists. Twelve boys ($17{\pm}1\;yr$, $175{\pm}5\;cm$, $70{\pm}9\;kg$) participated in anthropometric measurements, incremental exercise testing, and pulmonary function tests. During incremental exercise testing using a cycle ergometer, their maximal oxygen uptake ($VO_2max$), maximal power output, ventilation, ventilatory equivalents for oxygen ($V_E/VO_2$) and carbon dioxide ($V_E/VCO_2$), respiratory rate, and tidal volume were measured. Time variables such as inspiratory time (Ti), expiratory time (Te), breathing time (Tb), and inspiratory duty cycle (Ti/Tb), as well as inspiratory flow rate ($V_T$/Ti) were assessed. Pulmonary function of vital capacity (FVC), forced expiratory volume in one second ($FEV_1$), $FEV_1$/FVC, and peak expiratory flow were evaluated. Their $VO_2max$, maximal heart rate, and Wmax were $57.5{\pm}3.9\;ml{\cdot}kg^{-1}{\cdot}min^{-1}$, $194.1{\pm}8.6\;beat{\cdot}min^{-1}$, and 452 W, respectively. $VO_2max$ was not related to any anthropometric parameters. Most ventilatory variables progressively increased with exercise intensity. As intensity increased, Ti, Tb, Tb decreased while Ti/Tb was maintained. Below an intensity of 250 W, height, weight, body mass index, and body surface were highly correlated with $V_T$/Ti and Ti/Tb (p<0.05). Collectively, $VO_2max$ appeared to be lower than adult cyclists, suggesting a different pattern of ventilatory control as age advances. Morphological characteristics were not related to $VO_2max$ in the population. Time variables of ventilatory response seemed to be related only at an exercise intensity level of less than 250 W. $V_T$/Ti may be related to exercise endurance capacity, but Ti/Tb was similar to adult cyclists.

A 0.13-μm CMOS RF Front-End Transmitter For LTE-Advanced Systems (LTE-Advanced 표준을 지원하는 0.13-μm CMOS RF Front-end transmitter 설계)

  • Kim, Jong-Myeong;Kim, Chang-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.1009-1014
    • /
    • 2012
  • This paper has proposed a 2,500 MHz ~ 2,570 MHz 0.13-${\mu}m$ CMOS RF front-end transmitter for LTE-Advanced systems. The proposed RF front-end transmitter is composed of a quadrature up-conversion mixer and a driver amplifier. The measurement results show the maximum output power level is +6 dBm and the suppression ratio for the image sideband and LO leakage are better than -40 dBc respectively. The fabricated chip consumes 36 mA from a 1.2 V supply voltage.

A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Winter - Without Heat Loads from Occupancy - (대규모 실내경기장의 동계 온열환경 특성 실측조사 - 인체부하 미고려 조건 -)

  • Choi, Dong-Ho;Jeong, Seong-Jin;Seok, Ho-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.67-77
    • /
    • 2007
  • The purpose of this study is to provide fundamental heating design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with and without heating the space in winter. Heating loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF

A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Summer - Without Cooling Loads from Occupancy - (대규모 실내경기장의 하계 온열환경 특성 실측조사 - 인체부하 미고려 조건 -)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.6
    • /
    • pp.91-101
    • /
    • 2007
  • The purpose of this study is to provide fundamental cooling design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with and without cooling the space in summer. Colling loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF

The development of ultrasonic transmitter to enhance the efficiency of heat transfer rate in boiler (보일러내 열 전달 효율 개선을 위한 초음파발신기 개발)

  • Heo, Pil-Woo;Lee, Yang-Lae;Lim, Eui-Su;Koh, Kwang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.95-101
    • /
    • 2003
  • Ultrasonic transmitter used for scale prevention in boiler or heat exchanger is composed of the magnetostrictive material which transforms electric energy into ultrasonic wave and the horn which amplifies generated ultrasonic wave and transfers it into medium loaded. In this paper, we have performed the shape design for magnetostrictive material and analyzed a few type of horns which amplify generated ultrasonic wave and found each solution theoretically. Final length of the horn has been determined by measuring the sound pressure in medium between theoretical value and experience data. At last we have given the results of our study for the effects of ultrasonic wave irradiated by manufactured ultrasonic transmitter on preventing scale deposition on test pipe under the similar condition to boiler.

A Study on the Calculation Method of Load standard for ZEB activation (ZEB 활성화를 위한 부하기준 산정 방법 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.92-99
    • /
    • 2017
  • In Korea, the zero energy building was designated as the 7 new industries in the Ministry of Land and the 8 new industries in the Ministry of Industry. In order to maximize the insulation performance of the building envelope, improve the efficiency of building equipment, We are aiming. It is necessary to analyze the energy requirements of the buildings (cooling, heating, hot water supply, lighting, ventilation) of buildings with energy efficiency level of 1++ which is equivalent to the zero energy building certification system in Korea, It is aimed to be used as basic data for the advancement of energy building certification system. Zero Energy Building certification is estimated to be 61 buildings by 2017, and the approximate reference value and the first energy requirement for each of the five loads are calculated considering passive and active aspects. It is difficult to say that it is a clear standard because there is a small sample of data for calculating the load standard. However, it is necessary to interpret various methods in order to upgrade the Zero Energy Building certification standard in the future.

Early Response of Cardiopulmonary Exercise Test(CPET) in Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Radiation (방사선 치료 후 폐암환자의 운동부하 심.폐 기능의 초기변화)

  • Shin, Kyeong-Cheol;Lee, Deok-Hee;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • Background : Patients with locally advanced non-small cell lung cancer are often treated with radiation alone or in combination with chemotherapy. Both modalities have a potentially damaging effect on pulmonary function. In order to examine changes in the cardiopulmonary exercise function of patients with locally advanced non-small cell lung cancer before and after conventional radiotherapy, we conducted a prospective study involving patients with such cancer, that had received radiation therapy. Method : Resting pulmonary function test, thoracic radiographic finding and cardiopulmonary exercise test(CPET) were assessed prior to and 4 weeks following radiation therapy in 11 male patients with locally advanced non-small cell lung cancer. Patient with endobronchial mass were excluded. Results : The forces vital capacity (FVC), forced expiratory volume in 1 second ($FEV_1$ and maximal voluntary ventilation (MVV) did not decreased between before and 4 weeks after radiation but the diffusing capacity (DLCO) had decreased by 11% 4 weeks after radiation, which was not statistically significant. No changes in maximal oxygen consumption ($VO_2$max), carbon dioxide production ($VCO_2$), exercise time and work load were attributed to radiation therapy. Follow up cardiopulmonary exercise testing revealed unchanged cardiovascular function, ventilatory function and gas exchange. No difference in cardiopulmonary exercise test performance was observed between pre- and post-radiation. Conclusion : Cardiopulmonary exercise function did not decrease within the short-term after the radiation of patients with locally advanced non-small cell lung cancer.

  • PDF

A Survey on the Electric Power Consumptions of Apartments located at Coastal Area : Yeongdo-gu, Busan, Korea (연안지역 아파트의 전력소비량 실태조사 - 부산광역시 영도구에 대한 사례연구 -)

  • Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.241-245
    • /
    • 2009
  • Because of the heat island phenomenon and sea wind, there can be thermal conditions' differences around buildings at downtown and coastal area respectively in coastal city, like Busan, Incheon, Mokpo. For the final purpose of the buildings' energy saving design and operation considering of above mentioned environments differences, energy consumption including heating and cooling loads, electric loads are necessary to be accumulated and analyzed in as the database. As a part of this concept, this study aims to survey and analyze each loads of 22 apartments which has at least 100 households respectively and is located at Yeongdo island, Busan, Korea It is cleared that despite the residents living in this district can use sea wind as a natural ventilation and/or cooling methods, they mainly depends on the electric-driven air-conditioners for cooling with window-closed because of anti-salt problems of the sea wind. This leads the maximum power consumption of the surveyed-22-apartments to be appeared in August like that of inland buildings.

Inspiratory Flow Rate for the Evaluation of Bronchodilator in Patients with COPD (만성폐쇄성폐질환 환자에서 기관지확장제 흡입에 대한 흡기환기지표의 반응)

  • Baik, Jae-Joong;Park, Keon-Uk;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.342-350
    • /
    • 1995
  • Background: Although there are improvements of clinical symtoms after bronchodilator inhalation in COPD patients, it has been noted that there was no increase of $FEV_1$ in some cases. $FEV_1$ did not reflect precisely the improvement of ventilatory mechanics after bronchodilator inhalation in these COPD patients. The main pathophysiology of COPD is obstruction of airway in expiratory phase but in result, the load of respiratory system is increased in inspiratory phase. Therefore the improvement of clinical symptoms after bronchodilator inhalation may be due to the decrease of inspiratory load. So we performed the study which investigated the effect of bronchodilator on inspiratory response of vetilatory mechanics in COPD patients. Methods: In 17 stable COPD patients, inspiratory and expiratory forced flow-volume curves were measured respectively before bronchodilator inhalation. 10mg of salbutamol solution was inhaled via jet nebulizer for 4 minutes. Forced expiratory and inspiratory flow-volume curves were measured again 15 minutes after bronchodilator inhalation. Results: $FEV_1$, FVC and $FEV_1$/FVC% were $0.92{\pm}0.34L$($38.3{\pm}14.9%$ predicted), $2.5{\pm}0.81L$($71.1{\pm}21.0%$ predicted) and $43.1{\pm}14.5%$ respectively before bronchodilator inhalation. The values of increase of $FEV_1$, FVC and PIF(Peak Inspiratory Flow) were $0.15{\pm}0.13L$(relative increase: 17.0%), $0.58{\pm}0.38\;L$(29.0%) and $1.0{\pm}0.56L$/sec(37.5%) respectively after bronchodilator inhalation. The increase of PIF was twice more than $FEV_1$ in average(p<0.001). The increase of PIF in these patients whose $FEV_1$ was not increased after bronchodilator inhalation were 35.0%, 44.0% and 55.5% respectively. Conclusion: The inspiratory parameter reflected improvement of ventilatory mechanics by inhaled bronchodilater better than expiratory parameters in COPD patients.

  • PDF

A study on the performance enhancement for combined cycle using cold heat of LNG (LNG 냉열을 이용한 복합사이클 발전시스템의 성능개선연구)

  • 김용희;김병일
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.77-80
    • /
    • 1996
  • 우리나라에서 피크부하용으로 사용하는 복합발전이 하계시에서 외기온도가 상승함에 따라 실제로는 정격출력을 내지 못하고 있다. 따라서 본 연구에서는 연료(LNG)의 냉열을 이용하여 가스터빈의 연소용공기를 냉각시킬 경우, 복합발전 시스템의 성능변화를 분석하기 위하여 시뮬레이션을 수행하였다. 그 결과 LNG의 냉열을 이용하여 연소용공기를 원하는 온도까지 냉각시킬 수 있음을 확인할 수 있었다. 또한 연소기로 연료를 투입하기전에 설계온도까지 예열시키는 열교환기를 통해 배기가스에 함유된 현열을 더욱 많이 회수하면서, 가스터빈 투입연료의 온도를 상승시킬 수 있어, 시스템효율이 더욱 상승함을 알 수 있었다. 결론적으로 외기온도가 변하는 경우에, 본 시스템의 도입을 위해서는 경제성분석과 더불어 열교환기 시스템의 최적합성이 추후 진행되어야 할 것이며, 이를 통해 최적의 발전시스템을 구성할 수 있으리라 생각된다.

  • PDF