• Title/Summary/Keyword: 확산강조영상

Search Result 141, Processing Time 0.03 seconds

Gerstmann-Sträussler-Scheinker Disease: A Case Report (Gerstmann-Sträussler-Scheinker병: 증례 보고)

  • Minji Shin;Donghyun Kim;Young Jin Heo;Jin Wook Baek;Suyoung Yun;Hae Woong Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.745-749
    • /
    • 2023
  • Gerstmann-Sträussler-Scheinker (GSS) disease is a rare hereditary prion disease which is clinically characterized by a progressive cerebellar ataxia followed by cognitive impairment. We report a rare case of GSS disease in a 39-year-old male patient who complained of a progressive gait disturbance followed by dysarthria with cognitive impairment, after five months from the onset of initial symptom. His brain MRI scan revealed multifocal symmetric diffusion restricted lesions with T2/FLAIR hyperintensities in bilateral cerebral cortices, basal ganglia, and thalami. His family members also manifested similar symptoms in their 40-50s, suggesting the possibility of a genetic disease. Finally, he was genetically diagnosed with GSS disease by real-time quaking-induced conversion and prion protein (PRNP) gene sequencing test.

A Study on the Artifact Reduction Method of Magnetic Resonance Imaging in Dental Implants and Prostheses (치아 임플란트와 보철에서 발생하는 자기공명영상의 인공물 감소방안 연구)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1025-1033
    • /
    • 2019
  • Although magnetic resonance imaging without linear hardening of CT is recognized as a method of obtaining high contrast of tissue and excellent resolution image in brain disease and head and neck examination, magnetic susceptibility artifact is generated in case of metal implants in the oral cavity, which is an obstacle to image diagnosis. Therefore, an effort was made in this thesis to find a method to reduce artifacts caused by dental implants and prosthesis in MRI. Implant-induced artifacts in magnetic resonance imaging showed that the signal size increased with shorter TE in GE technique and was inconsistent with water temperature change. In SE technique as well, the signal size of water was generally higher than that of air, but the signal to noise ratio (SNR) was not different by air and temperature. In EPI technique, images with fewer artifacts were obtained quantitatively and qualitatively when there was more water than air, and the signal to noise ratio was measured the highest, especially at water temperatures of 20° and 30°. In conclusion, when examining using the EPI technique rather than the SE or the GE technique, obtaining brain diffusion using a 20° and 30° water bag reduces the magnetic susceptibility artifacts caused by implants and prosthesis, suggesting that it may provide images with high diagnostic value.

Atypical Presentation of Chronic Granulomatous Disease in a Neonate with a Pulmonary Granuloma Mimicking a Tumor: A Case Report (신생아에서 종양으로 오인되는 폐 육아종의 비전형적인 소견을 보인 만성 육아종성 질환: 증례 보고)

  • Young Jin Yoo;Joo Sung Sun;Jang Hoon Lee;Hyun Joo Jung;Yeong Hwa Koh;Joonho Jung;Hyun Gi Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.990-995
    • /
    • 2020
  • Chronic granulomatous disease (CGD) is an uncommon primary immune deficiency caused by phagocytes defective in oxygen metabolite production. It results in recurrent bacterial or fungal infections. Herein, we present a case of CGD with a large pulmonary granuloma in a neonate and review the imaging findings. The patient was a 24-day-old neonate admitted to the hospital with fever. A round opacified lesion was identified on the chest radiograph. Subsequent CT and MRI revealed a round mass with heterogeneous enhancement in the right lower lobe. There were foci of diffusion restriction in the mass. Surgical biopsy of the mass revealed chronic granuloma. Finally, the neonate was diagnosed with CGD caused by mutation of the gp91phox gene. Herein, we present the clinical and imaging findings of this unusual case of CGD.

Functional MRI of Visual cortex in the Patients with Occipital Lobe Ischemia (후두엽의 허혈성 뇌졸중 환자에서 시각피질의 기능적 자기공명영상)

  • 이영준;정태섭;윤영수;한승한;조영재;배준호
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.173-178
    • /
    • 1999
  • Purpose : To evaluate the usefulness of functional MRI (fMRI) of visual cortex in patients with ischemic infarction in the occipital lobe. Materials and Methods : Four patients with the symptoms and signs of visual cortical ischemia were included. Functional MRI was performed by 2D-FLASH technique with the parameter of 90/56msec TR/TE, $40^{\circ}$ flip angle, $240{\times}240{\;}FOV,{\;}64{\times}128$ matrix number, 8.32 seconds acquisition time, 8mm slice thickness. An axial slice including both visual cortices was selected and alternative activation and resting of the visual cortex was performed using red color photostimulator. all patients undertook visual field test, and vascular abnormality was examined by MRA (n=4) and DSA (n=2). fMRI results were compared with the results of a visual field test, conventional MRI and cerebral angiography. Results : On fMRI, decreased activity of the visual cortex was found in the occipital lobe corresponding to stenosis of the posterior cerebral artery or its branch noted on angiogram. However, 2 of 4 patients showed no abnormal findings on conventional MRI. Visual field defect was noted in 3 patients, one and of whom showed no abnormality on conventional MRI and diffusion-weighted image, but revealed decreased activity in the corresponding visual cortex on fMRI. Conclusion : fMRI may be a sensitive method for detection of the status of decreased blood flow or vascular reserve which other methods can not.

  • PDF

Edge Enhanced Error Diffusion based on Gradient Shaping of Original image (원영상의 기울기 성형을 이용한 경계강조 오차확산법)

  • 강태하;황병원
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.70-73
    • /
    • 2000
  • The error diffusion is good for reproducing continuous image to binary image. However the reproduction of edge characteristics is weak in power spectrum analysis of display error. It is suggested for us an edge-enhanced error-diffusion method that is included pre-processing algorithm for edge characteristic enhancement. Pre-processing algorithm is organized horizontal and vertical directional 2nd order differential values and weighting function of pre-filter. The improved Error diffusion using pre-filter, presents a good results visually which edge characteristics is enhanced. The performance of the proposed algorithm is compared with that of the conventional edge-enhanced error diffusion by measuring the RAPSD of display error, the egde correlation and the local average accordance.

  • PDF

Edge Enhancement due to Diffusion Effect in Magnetic Resonance Imaging (MR 영상에서 확산현상에 의한 경계강조)

  • Hong, I.K.;Ro, Y.M.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.124-127
    • /
    • 1995
  • Due to the self-diffusion of nuclear spins, the edge of phantoms is enhanced in the magnetic resonance imaging (MRI), especially in the case of microscopy [1]. According to several published works, theory has been established that the edge enhancement is caused by the motion narrowing around bounded regions due to diffusions of nuclear spins during data acquisition. It is found, however, that the signal decreases due to the diffusion attenuation and image is distorted as edge of the image is sharpened. In this paper, we wilt investigate this signal loss during data acquisition and its effects on image, i.e., image edge enhancement due to the diffusion phenomenon. This result is new and different from the previously discussed edge enhancement due to the diffusion, namely, by motion narrowing effect or spin bouncing effect at the boundary.

  • PDF

Edge Enhanced Error Diffusion based on Gradient Shaping of Original Image (원영상의 기울기 성형을 이용한 경계강조 오차확산법)

  • 강태하
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.10B
    • /
    • pp.1832-1840
    • /
    • 2000
  • The error diffusion algorithm is good for reproducing continuous images to binary images. However the reproduction of edge characteristics is weak in power spectrum an analysis of display error. In this paper an edge enhanced error diffusion method is proposed to improve the edge characteristic enhancement. Spatial gradient information in original image is adapted for edge enhance in threshold modulation of error diffusion. First the horizontal and vertical second order differential values are obtained from the gradient of peripheral pixels(3x3) in original image. second weighting function is composed by function including absolute value and sign of second order differential values. The proposed method presents a good visual results which edge characteristics is enhanced. The performance of the proposed method is compared with that of the conventional edge enhanced error diffusion by measuring the edge correlation and the local average accordance over a range of viewing distances and the RAPSD of display error.

  • PDF

Quantitative and Qualitative Evaluation of Brain Diffusion Weighted Magnetic Resonance Imaging: Comparision with 1.5 T and 3.0 T Units (뇌 확산강조 자기공명영상에 대한 정량적, 성적 평가: 1.5 T와 3.0 T 기기 비교)

  • Goo, Eun-Hoe;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.227-230
    • /
    • 2016
  • DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging. In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5T and 3.0T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5T.

Implementation of ARIA Block Encryption Algorithm (ARIA 블록 암호 알고리즘 구현)

  • Han, Jae-Su;Choi, Jin-Ku
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.64-67
    • /
    • 2011
  • 최근 개인 프라이버시 보호에 대한 중요성이 제기되면서, 보안에 대한 관심이 증가하게 되었다. 본 논문에서는 한국 산업규격 KS 표준 블록 암호 알고리즘인 ARIA의 핵심논리를 유지하면서, 동종 경쟁 알고리즘(AES, Camellia 등)과의 차별성으로 강조되어온 16 ${\times}16$ 이진 행렬을 이용한 확산 계층을$ (4{\times}4){\times}4$의 이진 행렬 형태로 수정한 개선 ARIA를 구현하였다. 개선 설계된 ARIA를 검증하기 위해, 파일 암.복호화 시스템을 적용하였고, 보안 영상 시스템을 개발하였다. 기존의 ARIA의 장점을 유지하기 때문에, 초경량 환경이나 많은 데이터를 초고속으로 처리에 필요한 응용에 더 효과적으로 적용될 수 있다.

An Automatic Contour Detection of 2-D Echocardiograms Using the Heat Anisotropic Diffusion Method (Heat Anisotropic Diffusion 방법을 이용한 2차원 심초음파도에서 경계선 자동 검출)

  • 신동조;김동윤
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.79-90
    • /
    • 1996
  • In this paper, we present an automatic threshold decision method to detect the contour of the a 2-D echocarodiogram by using the Bayes estimator for the boundary-like region. The boundary-like region is constructed from the conduction coefficient of the heat anisotro-pic diffusion method which enforces the blurred image during the preprocessing step. For the boundary-like region, we used the Bayes estimator to select an optimal threshold level. From this threshold value, the contour of the echocardigrams can be detected automatically Finally by overlapping the estimated contour to the original echocardiogram, we can obtain the contour enforced ultrasound echocardiogram.

  • PDF