• Title/Summary/Keyword: 화염 처리

Search Result 159, Processing Time 0.024 seconds

Herbicidal Properties of 5,8-dihydroxy-1,4-naphthoquinone and Their Possible Mode of Action (천연물 유래 5,8-dihydroxy-1,4-naphthoquinone의 살초특성과 작용기구)

  • Choi, Jung-Sup;Kim, Ji-Yeon;Seo, Bo-Ram;Ko, Young-Kwan;Cha, Mi-Ran;Kim, Young-Sup;Ryu, Shi-Yong;Hwang, In-Taek
    • Korean Journal of Weed Science
    • /
    • v.31 no.3
    • /
    • pp.250-259
    • /
    • 2011
  • This study was conducted to assess the possibility of 5,8-dihydroxy-1,4-naphthoquinone (DHNQ) as a environmental friendly herbicide candidate. Foliar application of DHNQ showed excellent herbicidal effect to the 3 grasses and 5 broad-leaved weeds. Among them, Digitaria sanguinalis and Solanum nigrum were completely controlled by $250{\mu}g\;mL^{-1}$ of DHNQ with main symptoms of desiccation or burndown within 24 hours. Aeschynomene indica was also sensitive to DHNQ treatment. All of the eight weed species were controlled by 90~100% at a concentration of $1000{\mu}g\;mL^{-1}$. However, soil application of DHNQ to Digitaria sanguinalis did not show any herbicidal symptoms. DHNQ strongly inhibited KAPAS activities in vitro and the $IC_{50}$ was $4.4{\mu}M$. Cellular leakage from cucumber leaf squares treated with DHNQ increased depending on the concentrations increased from 6.25 to $100{\mu}M$ after 24 hours incubation with or without light. However, chlorophyll loss in cucumber leaf squares was negligible. Biotin supplements significantly rescued the inhibition of germination rate of Arabidopsis thaliana seeds previously inhibited by the DHNQ. According to above results, DHNQ is a good natural herbicide candidate having a new target KAPAS, which is involved in biotin biosynthesis pathway, with environmental friendly.

Effect of Gaseous Chlorine Dioxide on Sterilization in Industrial Food-holding Cabinets (이산화염소가스를 이용한 식품산업용 소독장에서의 살균효과)

  • Kim, Hyeon Jeong;Shin, Jiyoung;Kim, Ji-eun;Yang, Ji-young
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.170-177
    • /
    • 2019
  • The aim of this study was to investigate the effect of different concentrations of chlorine dioxide ($ClO_2$) on sterilization and deodorization of food-holding cabinets under different exposure times. For the measuring sterilization and deodorization, a 6.5 L chamber and a 625 L cabinet with circulation systems were used. Two bacteria (Staphylococcus aureus KCTC1916 and Escherichia coli KCTC 1682) that were artificially inoculated in the plate respectively were put into the 6.5 L chamber and the 625 L cabinet. The $ClO_2$ gas was produced by ampules. In the 6.5 L chamber, neither of the two bacteria was detected after 24 hours treatment by $ClO_2$ gas. Moreover, the deodorization rate against ammonia and phenol was 94% and 70%, respectively, but deodorization against formaldehyde was not effective. When the concentration reached maximum (6 ampule, 4.6 ppm) levels in the cabinet, it lasted for approximately 2 h and then decreased slowly. When a circulator was used, the gas concentration was very low (6 ampule, 0.8 ppm) and the antibacterial activity against S. aureus and E. coli was low. The level of reduction against S. aureus and E. coli was 2.98 log CFU/plate and 6.06 log CFU/plate, respectively, in the cabinet after 24 h without a circulator. The reduction against S. aureus KCTC1916 and E. coli KCTC1682 was 2.69 log CFU/plate and 4.41 log CFU/plate for 24 h, respectively.

Numerical Study of Flow Characteristics in a Solid Particle Incinerator for Various Design Parameters of Injectors (고체 입자 소각로에서 분사기의 설계 인자에 따른 유동 특성에 관한 수치해석적 연구)

  • Son, Jin Woo;Kim, Su Ho;Sohn, Chae Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1079-1089
    • /
    • 2013
  • The flow characteristics in a solid particle incinerator are investigated numerically for high burning rate of wastes. The studied incinerator employs both a swirl flow used in the furnace of powerplants and a design concept applied to a rocket combustor. As the first step, the non-reactive flow field is analyzed in the incinerator with primary and secondary injectors through which solid fuel and air are injected. The deflection angle of a primary injector, inclination angle of a secondary injector, and gap between the two types of injectors are selected as design parameters. The swirl number is adopted for evaluating the degree of swirl flow and estimated over wide ranges of three parameters. The swirl number increases with deflection angle, but it is affected little by inclination angle. Recirculation zones are formed near the injectors, and their size affects the swirl number. The swirl number decreases with the zonal size of recirculation. From the numerical results, the design points can be found with strong swirl flow.

A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy (다중이용업소의 내장재 규정의 적용에 관한 연구)

  • 이주헌;윤명오;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.100-107
    • /
    • 2001
  • A Interior material, a main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Nonetheless, it has been used recklessly with undue attention to its contribution to fire in particular in entertainment occupancy and causes many victims in fire. Therefore, this study attempts to examine the current use of interior material in Korea and find out what to be improved and enhanced in terms of related regulations. Based on the comparison and analysis of the Korea regulation with those of advanced nations, suggestions are made for an effective and efficient improvement and complement to the current system. What can be suggested from this study are as follows. The use of interior material should be controlled under the unified regulation of fire-safety codes. Code should be set up so that the current construction enforcement should be applied in retroactive to those entertainment buildings that obtained a license prior to the implementation of the system certifying that the building is fire-resistant and fire-protective. The legislation should be made to control the fire-protection facilities of small-sized, underground entertainments. It should be obliged to present the blueprint displaying the use of interior material at the time of changing occupancy. Or, it should be compelled to report changes that go way without permit to the administrative office. A compulsory provision should be set up to have a fire-resistant performance to movable furniture. The classification index designating the fire hazard of interior material by flame spread rate and smoke toxicity and its test method should be established.

  • PDF

A Study on the Development of $CO_2$ Recycle Oxy-Fuel Combustion Heating System ($CO_2$ 재순환형 산소연소 가열시스템 개발에 관한 연구)

  • Jeong Yu-Seok;Lee Eun-Kyung;Go Chang-Bok;Jang Byung-Lok;Han Hyung-Kee;Noh Dong-Soon
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2006.05a
    • /
    • pp.412-419
    • /
    • 2006
  • An Experimental study was conducted on $CO_{2}$ recycle combustion heating system using pure oxygen instead of conventional air as an oxidant, which is thereby producing a flue gas of mostly $CO_{2}$ and water vapor($H_{2}O$ and water vapor($H_{2}O$) and resulting in higher $CO_{2}$ concentration. The advantages of the system are not only the ability to control high temperatures characteristic of oxygen combustion with recycling $CO_{2}$ but also the possibility to reduce NOx emission in the flue gas. A small scale industrial reheating furnace simulator and specially designed variable flame burner were used to characterize the $CO_{2}$ recycle oxy-fuel combustion, such as the variations of furnace pressure, temperature and composition in the flue gas during recycle. It was found that $CO_{2}$ concentration in the flue gas was about 80% without $CO_{2}$recycle. The furnace temperature and pressure and pressure were decreased due to recycle and the NOx emission was also reduced to maintain under 100ppm.

  • PDF

A Study on Fire Performance Evaluation of EIFS on Anti-Flaming Finish by Cone Calorimeter Test (콘칼로리미터에 의한 외단열시스템의 방염 화재성능평가를 위한 연구)

  • Min, Se-Hong;Sun, Ju-Seok;Kim, Sang-Chul;Choi, Yong-Mook;Lee, Seok-Ki
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.106-111
    • /
    • 2012
  • In this study, EIFS (Exterior insulation finish system) of exterior cladding was applied Cone calorimeter test to confirm the effect of flame retardant. As a results, the initial ignition points in accordance with the coated form and concentration of the flame retardant was delayed. But flame resistant treatment of EIFS cladding to control the fire will not affect confirmed that. In addition, EIFS that uses high-density and low-density due to difference in the density of the impact of the fire was no difference. The exterior of the ignition experiment occurred before and after 40 seconds, heat release rate to 100 seconds appears to occur about 90 % compared with the other exterior wall materials, the initial fire spread very fast was confirmed. EIFS cladding in order to prevent the spread of fire in the application of EIFS legally use is limited by the use of the building. And flame spread can be prevented, such as a vertical outer wall compartment measures are urgently needed.

Enhanced Flame Retardancy of Cotton Fabric by Functionalized Graphene Oxide and Ammonium Polyphosphate (기능성화 산화 그래핀과 폴리인산암모늄을 이용한 직물 난연성 향상)

  • Ka, Dongwon;Jang, Seongon;Jung, Hyunsook;Jin, Youngho
    • Composites Research
    • /
    • v.33 no.4
    • /
    • pp.177-184
    • /
    • 2020
  • Flame retardant(FR) clothes prohibit additional fire diffusion and make the personnel do their tasks without a hitch in a flammable environment. The existing FR clothes, however, are heavy and give high thermal fatigue. Therefore, it is strongly demanded to develop a light, convenient, and eco-friendly clothes. Recently, many works have been reported to make FR fabrics with phosphorus compounds, but their performance could not satisfy the specified criteria in appraisal standards of domestic and American FR clothes or combat uniforms. In this paper, two kinds of phosphorus compounds were applied to cotton fabric. Graphene oxide functionalized with a phosphorus-rich deep eutectic solvent and ammonium polyphosphate were coated on cotton fabric by eco-friendly padding procedure. The coated fabrics were analyzed with thermogravimetric analysis, vertical flame resistance test(ASTM D6413), cone calorimeter test(ISO 5660-1), and method of test for limited flame spread(ISO 15025). It was revealed that the as-made cotton with those two materials simultaneously had better flame resistance than the cottons with each one. Furthermore, an additional coating for hydrophobicity on the FR cotton was tried for better washing fastness.

Evaluation of EGR applicability for NOx reduction in lean-burn LPG direct injection engine (초희박 LPG 직접분사식 엔진에서 질소산화물 저감을 위한 배기재순환 적용성 평가)

  • Park, Cheolwoong;Cho, Seehyeon;Kim, Taeyoung;Cho, Gyubaek;Lee, Janghee
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.22-28
    • /
    • 2015
  • In order to keep the competitiveness of LPG fuel for transportation fuel, the difference in fuel consumption with gasoline and cost for an aftertreatment system should be reduced with continuous development of technology for LPG engine. In the present study, spray-guided type direct injection combustion system, whose configuration is composed of direct injector in the vicinity of spark plug, was employed to realize stable lean combustion. A certain level of nitrogen oxides($NO_x$) emits due to a locally rich mixture regions in the stratified mixture. With the application of EGR system for the reduction of $NO_x$, 15% of $NO_x$ reduction was achieved whereas fuel consumption and hydrocarbon emission increased. By the application of EGR, the combustion speed reduced especially appeared at initial flame development period and peak heat release rates and increasing rates for heat release rate decreased as EGR rate increased due to the dilution effect of intake air.

Microscopic Study of Decomposition-Inhibition in Stabilized $ClO_2$ Gas in Skeletal Muscle of Rat (흰쥐 골격근에서 안정화 이산화염소(Stabilized $ClO_2$)의 부패억제에 관한 현미경적 연구)

  • Hwang, Kyu-Sung;Jeong, Moon-Jin;Jeong, Soon-Jeong;Ahn, Yong-Soon;Lim, Do-Seon
    • Applied Microscopy
    • /
    • v.41 no.4
    • /
    • pp.277-284
    • /
    • 2011
  • This study was conducted to determine the antiseptic effect of stabilized chlorine dioxide (S-$ClO_2$) on muscle tissue of rats. Skeletal muscle of 8-week old Sprague-Dawley rats was used. Light and transmission electron microscopic findings were observed in the control group, which was not treated with stabilized chlorine dioxide, and in the experimental group, which was treated with a stabilized chlorine dioxide powder in aqueous solution. According to the LM and TEM observations, the day 1 control group showed the initiation of endomysium collapse resulting in an unclear boundary of muscle fibers, and partial collapse of the mitochondrial membranes. All endomysium had collapsed, and bacteria were observed among muscle fibers in the day 2 and later groups. Shapes of muscles were not distinguishable in day 3 or later groups. In contrast, the day 1 and 3 experimental groups revealed detailed structure of typical muscles, but partial collapse of the mitochondrial membranes was observed in the day 3 and later groups. Subsequently, connective tissues collapsed and structures in the shape of concentric circles were observed. In summary, the day 1 control group showed the initial collapse of tissues, and shapes were not distinguishable in the day 3 and later groups because most of the tissues had collapsed. In contrast, the day 3 experimental group showed partial collapse, but the overall shapes of muscles were maintained as time went on, confirming the antiseptic effect of stabilized chlorine dioxide on muscles.