Abstract
In this study, EIFS (Exterior insulation finish system) of exterior cladding was applied Cone calorimeter test to confirm the effect of flame retardant. As a results, the initial ignition points in accordance with the coated form and concentration of the flame retardant was delayed. But flame resistant treatment of EIFS cladding to control the fire will not affect confirmed that. In addition, EIFS that uses high-density and low-density due to difference in the density of the impact of the fire was no difference. The exterior of the ignition experiment occurred before and after 40 seconds, heat release rate to 100 seconds appears to occur about 90 % compared with the other exterior wall materials, the initial fire spread very fast was confirmed. EIFS cladding in order to prevent the spread of fire in the application of EIFS legally use is limited by the use of the building. And flame spread can be prevented, such as a vertical outer wall compartment measures are urgently needed.
Keywords
EIFS (Exterior Insulating and Finishing System); ISO 5660-1; EN 13823;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 S. H. Min, J. E. Yoon and M. S. Kim, "An Experimental Study on Combustion Characteristics of Aluminum Composite Panels for Flame Retardant and General Materials", Journal of Korean Institute of Fire Science & Engineering, Vol. 26, No. 2, pp. 105-111 (2012).   DOI
2 S. J. Lee, "An Improvement of Exterior Finishes in Building Remodeling (Focused on Exterior Insulation and Finishing)", DongGuk University, Academic Thesis (2003).
3 G. L. Christensen, "Full scale Fire Test of Various Exterior Wall System, Development, Use and Performance of Exterior Insulation & Finish System (EIFS), ASTM STP1187, Mark F. Williams and Richard G. Lampo, Eds., American Society for Testing and Materials, Philadelphia (1995).
4 A yearbook about fire statistics (2007. 2008), Homepage data of National Emergency Management Agency (2010).
5 2007-2008 Disaster Reports of Fires, Archives of National Emergency Management Agency (2010).
6 KS F ISO 5660-1 Fire Tests for Combustion (Cone Calorimeter Test), Korea Standard Association) (2009).
7 KOFEIS 1001 Article 4. "Flame Resistance Performance Criteria".
8 S. H. Min and J. E. Yoon, "A Study on the Modeling of Vertical Spread Fire of Exterior Panel by Fire Dynamic Simulation (FDS)", Journal of the Korea Safety Management & Science, Vol. 11, No. 2, pp. 77-85 (2009).
9 S. H. Min and M. S. Kim, "A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test", Journal of the Korea Safety Management & Science, Vol. 12, No. 1, pp. 1-9 (2010).