• Title/Summary/Keyword: 혼합소각

Search Result 90, Processing Time 0.03 seconds

The Feasibility of Co-Incineration for Municipal Solid Waste and Sewage Sludge through the Change of Heat Loading and Atmospheric Pollutants Loading (하수슬러지와 생활폐기물 혼합소각시 열부하 변화 및 대기오염물질 부하 변화를 통한 혼합소각 가능성에 관한 연구)

  • Cho, Jae-Beom;Kim, Woo-Gu;Yeon, Kyeong-Ho;Shin, Jung-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.583-589
    • /
    • 2012
  • The various promotion countermeasures such as solidification, carbonization, and the creation of cement materials have been considered to existing treatment methods such as incineration and the creation of composts, since direct landfill was prohibited for encouraging the recycling based on the sludge treatment on land. The Main objective of this study is to investigate the feasibility of co-incineration for MSW (Municipal Solid Waste) and SS (Sewage Sludge) through the change of heat and atmospheric pollutants. In this study, LHV (Low Heating Value) is 100~300 kcal/kg because the MC (Moisture Content) of de-hydrated sewage sludge is approximately 80%. From the results, we knew the feasibility of co-incineration for MSW (80%) and SS (20%). As the co-incineration rate of SS up to 20% became higher, the loading of heat and atmospheric pollutants was not influenced.

A Study on the Problems of Incinerating Facility and Plans to Improve in Regard to Separate Discharge of Food Waste (음식물류폐기물 분리배출에 따른 소각시설의 문제점과 개선방안에 관한 연구)

  • Kim, Seong-Jung;Kim, Dong-Hyuk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.4
    • /
    • pp.74-81
    • /
    • 2008
  • Due to separate discharge of food waste, large incinerating facilities for municipal waste show the phase change that combustible contents have been increasing while the concentrations of water have been decreasing when wastes are brought in. This phase change of wastes leads to the increase of exothermic value when wastes are carried in, which causes the problems to make the durability of incinerating facilities weak and lower the capacities of them. In accordance with these problems, this study was carried out to present effective plans to operate incinerating facilities as the quantities of municipal wastes of Incheon have been gradually increasing. We examined the problems caused by the phase change of municipal waste in Incheon and managing plans to control the amounts of heat output when intermixed incineration of food waste is conducted. It is concluded that we could carry out the optimized operation of incinerating facilities as well as produce economic effect to reduce processing costs when we conduct the intermixed incineration of food waste and municipal waste, in the trend that the amounts of heat output generated by wastes are gradually increasing. This is because this operation of intermixing incineration contributes to reducing the amount of exothermic heat.

  • PDF

Feasibility Evaluation of Co-Incineration with MSW for Efficient Recycling of the Rejects after Separation Processes in MRF (재활용 기반시설에서 발생하는 선별 잔재물의 자원화를 위한 도시생활폐기물과의 혼합소각 가능성 평가)

  • Shin, Taek-Soo;Sung, Baek-Nam;Yeon, Ik-Jun;Cho, Byung-Yeol;Kim, Kwang-Yul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.767-773
    • /
    • 2011
  • The purpose of this study was to investigate the possibility of an alternative fuel resource by incinerating a mix of combustible MSW (municipal solid waste) and offals after separating recyclable material at the MRF (material recovery facilities) location. We analyzed the physical and chemical properties including the 3-contents, the calorific value, and chemical compositions of the separation rejects in MRF, and compared the results with combustible MSW. Moreover, we experimented the trend of combustible properties and the concentration change of air pollutants at mixed incineration in the MSW incinerator. According to the results of the experiment, the separation rejects showed higher heating value (5,865 kcal/kg), and lower moisture and ash content than combustible MSW. Since we have incinerated MSW in the MSW incinerator mixing the offals at 30% and 50% respectively, we know that the change of the concentration of dust, $SO_2$, $NO_2$, and CO did not appear significant, and not exceed the pollutants emission regulation. But, considering the enhancement of the HCl emission concentration (max. 33.7 ppm) at the co-incineration of the 50% offals, we believe that the proper mixing ratio of the separation rejects would become within 30%.

Co-incineration Characteristics of Sewage Sludge and Industrial Waste Using the Rotary Kiln Incinerator (로타리킬른 소각로를 이용한 하수슬러지와 사업장폐기물의 혼합소각 특성)

  • Yang, Dong-Jib;Ko, Jae-Cheol;Kim, Jeong-Keun;Park, Hui-Jae;Park, Joon-Seok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.3
    • /
    • pp.91-99
    • /
    • 2009
  • This research were performed to evaluate co-incineration characteristics of sewage sludge and industrial waste in rotary kiln incinerator, and provide the fundamental data. Plastic portion (42.55%) in this industrial waste showed over 3 times higher than that (11.92%) of paper. Korean proximate analysis of the waste mixed with sewage sludge and industrial waste (3 : 7, volumetric basis) showed 16.3% of moisture, 70.5% of volatile solids, and 13.2% of ash, respectively. Low heating value of the mixed waste was 4,513kcal/kg. So it was thought that the mixed waste of sewage sludge and industrial waste (containing 43% of plastics and 12% papers) has enough heating value for co-incineration. The incineration of mixed waste showed the lowest SOx and NOx concentrations at $700^{\circ}C$. However, the operation at $950^{\circ}C$ was feasible in considering dioxin and the other hazardous gases. It was concluded that use of $Ca(OH)_2$ should be under investigation for the operation at $950^{\circ}C$.

  • PDF

A Study on Quantitative Supply of Sewage Sludge for Co-Incineration of Municipal Solid Waste and Sewage Sludge (하수슬러지와 생활폐기물 혼합소각시 하수슬러지 정량공급에 관한 연구 - Batch Test 중심으로)

  • Cho, Jae-Beom;Kim, Woo-Gu;Yeon, Kyeong-Ho;Shin, Jung-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.64-69
    • /
    • 2013
  • The various promotion countermeasures such as solidification, carbonization, and the creation of cement materials have been considered to existing treatment methods such as incineration and the creation of composts, since direct landfill was prohibited for encouraging the recycling based on the sludge treatment on land. The Main objective of this study is to investigate the feasibility of co-incineration for MSW (municipal solid waste) and SS (sewage sludge) through the quantitative supply of sewage sludge. In this study, optimum water content to operate normally incinerator is 85%. In order to increase the workability of sewage sludge, it is necessary to supply properly water. In the case study of sites, optimum water content is 87% due to the water evaporation. Therefore, it was found that the water content up to 87% would be reached the stable operation of co-incinerator on the mixture of municipal waste solid and sewage sludge.

Use of Sewage Sludge Ash for Construction Material (건설재로서 하수슬러지 소각재의 활용)

  • Lee, Cheo-Keun;Ahn, Kwang-Kuk;Heo, Yol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.4
    • /
    • pp.25-34
    • /
    • 2003
  • This paper is focused on an experimental study in order to investigate the utilization of sewage sludge ash as the cover and liner materials for the waste disposal landfill or as construction materials. A series of tests were performed to evaluate the basic properties, compaction, compressive strength, consolidation, permeability, and CBR of sewage ash. Specially, clay bricks were made as increasing replacement ratio of sewage ash (such as 5, 10, 15, 20, 25, 30%). And tests were fulfilled for its quality. Bentonite and lime were used as the additives to improve permeability properties of sewage sludge ash. As a result of tests, it was shown that the permeability coefficient decreases as increasing bentonite content and the percentage of bentonite was roughly needed 20% to keep the permeability coefficient below $1{\times}10^{-7}cm/sec$. The results of unconfined compression tests show that sewage ash meets the criteria of the unconfined compression strength for cover material. It was shown that the compressive strength decreases as increasing the replacement ratio of sewage sludge ash and the maximum replacement ratio of sewage sludge ash to satisfy the quality standards of the third degree bricks was about 15%.

  • PDF

A study on Quantitative Supply of Sewage Sludge for Co-Incineration of Municipal Solid Waste and Sewage Sludge(II) - Based on Actual Incineration Plant (하수슬러지와 생활폐기물 혼합소각시 하수슬러지 정량공급에 관한 연구(II) - 실증플랜트 중심으로)

  • Cho, Jae-Beom;Kim, Woo-Gu;Jang, Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.960-966
    • /
    • 2013
  • In this study, operation data from an actual plant in M city were analyzed to evaluate effects of water supply into sewage sludge on the co-incineration of municipal solid waste (MSW) and sewage sludge. Design capacity of the stoker incinerator is 50 m3/day. Maximum portion of sewage sludge in the total waste input was 20%. According to this research, moisture content increase up to 85% of sewage sludge could be possible by water supply on MSW input to the incinerator. Therefore, stable operation of incinerator could be achieved. As water was added into sewage sludge up to 85%, input quantity of sewage sludge to frequency (Hz) was similar to theoretical input. Also, it is concluded that stable management of incinerator without leachate combustion and damages of refractory bricks and castable could be achieved by the reduction of low heating value.

An Experimental Study on the Quality of Concrete with Municipal Solid Waste Incineration Ash (쓰레기 소각재 사용 콘크리트의 품질특성에 대한 실험적 연구)

  • Kim, Jae-Woo;Choi, Jae-Jin;Moon, Dae-Joong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.4
    • /
    • pp.335-344
    • /
    • 2014
  • The Quality of municipal solid waste incineration ash (incineration ash) was analyzed for the purpose of the reusing for concrete material. The folwability and strength properties of concrete mixed with incinerator ash were investigated. CaO component was included more than 50% in chemical component of incinerator ash, mean size of 50% accumulated particle distribution of incinerator ash was about $25{\mu}m$. Particle shape of incinerator ash ($IA_1$) was massed the round shape with fine particle, particle shape of incinerator ash ($IA_2$) was piled up the sheet shape according to manufacture procedure. The Quality of concrete was effected by use of incinerator ash. When the incinerator Ash ($IA_2$) was used, slum of concrete was increased and dosage of high range water reducing agent was reduced. However, strength development of concrete was decreased. Dosage of high range water reducing agent was increased by combined use of incinerator ash ($IA_2$) and diatomite powder, but strength development of concrete was improved. Ratio of compressive strength and tensile strength was in the range 85%~105% of CEB-FIP model code.

A Study on the RDF fuel mixing with household and organic wastes (생활(生活)쓰레기 및 유기성폐기물(有機性廢棄物) 혼합(混合)에 따른 RDF 연료화(燃料化)에 관한 연구(硏究))

  • Ha, Sang-An;You, Mi-Young;Kim, Dong-Kyun;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.20 no.5
    • /
    • pp.52-57
    • /
    • 2011
  • This study was conducted to examine the possibilities to utilize the mixture of domestic and organic wastes from B-city as a fuel. All types of mixing ratio for uncarried waste, sludge cake, and food waste were found 10 generate heating value with 6,000 kcal/kg, and in case of sludge cake the concentration of toxic substance produced was found to be decreased as air-fuel ratio and temperature were increased. It was noted that toxic gases such as CO, NOx, and SOx were observed below concentration of emission standard, and temperature inside the incinerator was stabilized at 2 of air-fuel ratio and 800$^{\circ}C$. It was observed that a heating value of 6000 kcal/kg generated using RDF(Refuse Derived Fuel) was appropriate to utilize a fuel if a complete combustion was attained.

Study on the heavy metal stabilization by dosing of chelate on the bottom ash (소각재에서의 용출억제제를 이용한 중금속 안정화에 관한 연구)

  • Jang, Hyeon-Jong;Kim, Seong-Jung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.4
    • /
    • pp.81-90
    • /
    • 2009
  • About 35 domestic incinerators are being operated currently. There is waste management policy to reuse waste efficiently and reduce waste through incineration which include reuse, recycling and energy recovery. However, there is a critical social issue that some heavy metals(Cu, Pb) were found in bottom ash from incineration of waste. After incineration, bottom ash is treated with chemicals to prevent second pollution of heavy metals from bottom ash and increase efficiency of heavy metal stabilization.

  • PDF