• Title/Summary/Keyword: 호흡 규칙성

Search Result 15, Processing Time 0.022 seconds

Development of Respiratory Training System Using Individual Characteristic Guiding Waveform (환자고유의 호흡 패턴을 적용한 호흡 연습장치 개발 및 유용성 평가)

  • Kang, Seong-Hee;Yoon, Jai-Woong;Kim, Tae-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • The purpose of this study was to develop the respiratory training system using individual characteristic guiding waveform to reduce the impact of respiratory motion that causes artifact in radiotherapy. In order to evaluate the improvement of respiratory regularity, 5 volunteers were included and their respiratory signals were acquired using the in-house developed belt-type sensor. Respiratory training system needs 10 free breathing cycles of each volunteer to make individual characteristic guiding waveform based on Fourier series and it guides patient's next breathing. For each volunteer, free breathing and guided breathing which uses individual characteristic guiding waveform were performed to acquire the respiratory cycles for 3 min. The root mean square error (RMSE) was computed to analyze improvement of respiratory regularity in period and displacement. It was found that respiratory regularity was improved by using respiratory training system. RMSE of guided breathing decreased up to 40% in displacement and 76% in period compared with free breathing. In conclusion, since the guiding waveform was easy to follow for the volunteers, the respiratory regularity was significantly improved by using in-house developed respiratory training system. So it would be helpful to improve accuracy and efficiency during 4D-RT, 4D-CT.

Development and usability evaluation of portable respiration training device which is applied to personal respiration cycle (개인고유의 호흡주기를 적용한 휴대형 호흡 연습장치 개발 및 유용성 평가)

  • Park, Mun-kyu;Lee, Dong-han;Cho, Yu-ra;Hwang, Seon-bung;Park, Seung-woo;Lee, Dong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.833-835
    • /
    • 2014
  • On this study, we have developed respiratory training system to improve stability of respiration, one of the most important factors of Respiratory Gated Radiation Therapy, RGRT. Respiratory training system that we developed was applied to personal respiratory cycle so that it could provide comfortable respiratory triggering to patients. To give sufficient time for practice, we used modular portable device to practice easily and to be undetered by time and place. We have intended to improve efficiency and accuracy by providing it to patients. We are now planning to conduct experiment of 10 peoples to find out stability, degree of durability betterment and regularity of respiration when patients are using respiratory training system. There are three kinds of breathing style. First is free breathing that Individual patients can breathe freely. Second is guide breathing that patients apply to personal respiration cycle through the guiding sight and hearing program. Third is prediction breathing that patients breathe after respiratory training without guiding sight and hearing program. By using these 3 data of respiration method, we have evaluated usability of respiratory training system by quantitatively analyzing respiration period, amplitude and area's variation.

  • PDF

Evaluation of Dose Distributions calculated with ITV Measurement Plan Data and PTV Measurement plan Data under the condition of Respiratory Motion during 3D for ABD Cancer (내부표적체적 기반의 치료계획과 호흡연동 기법을 적용한 치료계획과의 선량비교 분석)

  • Park, Ho-Chun;Han, Jae-Bok;Song, Jong-Nam;Choi, Nam-Gil
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.227-228
    • /
    • 2014
  • 방사선치료의 발전으로 3차원치료보다 진보된 호흡연동방사선치료가 시행되어지고 있다. 호흡의 규칙성과 환자의 위치 재현성이 중요한 치료적응 인자이며, 호흡연동 방사선치료의 효율을 높일 수 있는 지표이다. 국가암통계상 고령의 암환자가 증가하며, 수술, 화학요법을 병행하는 암 치료법이 널리 이용이 되고 있다. 고식적인 치료를 요하는 고령의 복부 암 환자분들에 호흡연동 방사선치료법을 사용하는데 에는 호흡의 불규칙성과 체위의 재현성의 문제점으로 인한 치료 효율의 저하를 가져온다. 본 연구에서는 호흡에 의한 종양 움직임이 있는 방사선 치료에서 내부표적체적 기반의 치료계획과 호흡연동 기법을 적용한 치료계획과의 선량비교 분석하였다. 2가지 치료법 모두 정상조직 보호선량에 부합한 것으로 나타났으며 치료체적은 처방선량의 95%이상 포함된 선량분포로 적합하였다. ITV 설정을 통한 3D Plan은 고식적 치료을 목적으로 하는 고령의 환자, 체위 및 호흡의 불안정성 환자에게 처방선량의 95% 이상의 4D Plan의 치료법 보다 짧은 시간에 치료함으로써 치료효율을 높일 수 있을 거라 사료된다. 다만 정상조직보호선량(NTCP)에 부합하는지에 대한 평가가 전제되어야 한다.

  • PDF

Efficacy of a Respiratory Training System on the Regularity of Breathing (호흡연습장치를 적용한 호흡교정법의 영향 평가)

  • Shin, Eun-Hyuk;Park, Hee-Chul;Han, Young-YIh;Ju, Sang-Gyu;Shin, Jung-Suk;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.181-188
    • /
    • 2008
  • Purpose: In order to enhance the efficiency of respiratory gated 4-dimensional radiation therapy for more regular and stable respiratory period and amplitude, a respiration training system was designed, and its efficacy was evaluated. Materials and Methods: The experiment was designed to measure the difference in respiration regularity following the use of a training system. A total of 11 subjects (9 volunteers and 2 patients) were included in the experiments. Three different breathing signals, including free breathing (free-breathing), guided breathing that followed training software (guided-breathing), and free breathing after the guided-breathing (post guided-breathing), were consecutively recorded in each subject. The peak-to-peak (PTP) period of the breathing signal, standard deviation (SD), peak-amplitude and its SD, area of the one cycle of the breathing wave form, and its root mean square (RMS) were measured and computed. Results: The temporal regularity was significantly improved in guided-breathing since the SD of breathing period reduced (free-breathing 0.568 vs guided-breathing 0.344, p=0.0013). The SD of the breathing period representing the post guided-breathing was also reduced, but the difference was not statistically significant (free-breathing 0.568 vs. guided-breathing 0.512, p=ns). Also the SD of measured amplitude was reduced in guided-breathing (free-breathing 1.317 vs. guided-breathing 1.068, p=0.187), although not significant. This indicated that the tidal volume for each breath was kept more even in guided-breathing compared to free-breathing. There was no change in breathing pattern between free-breathing and guided-breathing. The average area of breathing wave form and its RMS in postguided-breathing, however, was reduced by 7% and 5.9%, respectively. Conclusion: The guided-breathing was more stable and regular than the other forms of breathing data. Therefore, the developed respiratory training system was effective in improving the temporal regularity and maintaining a more even tidal volume.

Development of Movement Analysis Program and its Feasibility Test in Streotactic Body Radiation Threrapy (복부부위의 체부정위방사선치료시 호흡에 의한 움직임분석 프로그램 개발 및 유용성 평가)

  • Shin, Eun-Hyuk;Han, Young-Yih;Kim, Jin-Sung;Park, Hee-Chul;Shin, Jung-Suk;Ju, Sang-Gyu;Lee, Ji-Hea;Ahn, Jong-Ho;Lee, Jai-Ki;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2011
  • Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Development and Utility Evaluation of Portable Respiration Training Device for Image-guided Stereotactic Body Radiation Therapy (SBRT) (영상유도 체부정위방사선 치료시 호흡동조를 위한 휴대형 호흡연습장치의 개발 및 유용성 평가)

  • Hwang, Seon Bung;Park, Mun Kyu;Park, Seung Woo;Cho, Yu Ra;Lee, Dong Han;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.264-270
    • /
    • 2014
  • This study developed a portable respiratory training device to improve breathing stability, which is an important element in using the CyberKnife Synchrony respiratory tracking device, one of the typical Stereotactic Radiation Therapy (SRT) devices. It produced an interface for users to be able to select one of two displays, a graph type and a bar type, supported an auditory system that helps them expect next respiration by improving a sense of rhythm of their respiratory period, and provided comfortable respiratory inducement. By targeting 5 applicants and applying individual respiratory period detected through a self-developed program, it acquired signal data of 'guide respiration' that induces breathing through signal data gained from 'free respiration' and an auditory system, and evaluated the usability by comparing deviation average values of respiratory period and respiratory amplitude. It could be identified that respiratory period decreased $55.74{\pm}0.14%$ compared to free respiration, and respiratory amplitude decreased $28.12{\pm}0.10%$ compared to free respiration, which confirmed the consistency and stability of respiratory. SBRT, developed based on these results, using the portable respiratory training device, for liver cancer or lung cancer, is evaluated to be able to help reduce delayed treatment time due to respiratory instability and improve treatment accuracy, and if it could be applied to developing respiratory training applications targeting an android-based portable device in the future, even use convenience and economic efficiency are expected.

Herbst Oral Appliance for Obstructive Sleep Apnea When Uvulopalatopharyngoplasty and Nasal CPAP Failed (구개수구개인두성형술 및 지속적 기도 양압 공급치료에 실패하였으나 Herbst 구강내 장치로 효과를 보인 폐쇄성 수면 무호흡 증후군 1예)

  • Moon, Hwa-Sik;Choi, Young-Mee;Kim, Myung-Lip;Park, Young-Hak;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.457-464
    • /
    • 1998
  • This report describes a 5-month follow-up of the efficacy of Herbst oral appliance(OA) in a obstructive sleep apnea syndrome patient who has failed with uvulopalatopharyngoplasty(UPPP) and was unable to tolerate to subsequent nasal continuous positive airway pressure(CPAP) because of mouth air leak. The obstructive sleep apnea and daytime performance were markedly improved by regular home use of OA, and the patient still continues to use OA without complications. It is suggested that OA can be a successful alternative therapeutic modality in patients who are unable to tolerate to nasal CP AP, especially after UPPP.

  • PDF

New Directions of Particulate Control Technology (새로운 집진기술 동향)

  • 김용진;정상현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.221-231
    • /
    • 1995
  • 산업발달에 따라 불가피하게 생성되며, 대기오염의 주종을 이루면서 인체에 가장 유해한 분진입자는 산업체의 오일(oil) 및 석탄연소 보일러, 자동차, 제철/제강 및 시멘트 플랜트 등으로 부터 배출되는 미세입자(fine particle)들이며, 앞으로 이들의 제어에 관한 연구가 지속적인 관심의 대상이 될 것이다. 한 예로, 석탄연소 화력발전소로부터 1$\mum$ 이하의 입자들의 배출량은 무게비로는 1% 이하이지만 입자수의 비율에서는99%를 차지하고 있다. 이들은 매우 높은 중금속 함유량을 지니고 있기 때문에 인체의 호흡시 심각한 문제를 유발시킬 뿐만 아니라, 이러한 미세입자들은 대기중에 부유하고 있다가 비(rain)에 의하여 세정되어 수질오염까지도 유발시킨다. 1992년 2월 공포된 대기환경보전법 시행규칙에 따라 분진배출 허용기준이 장기 입법예고 되므로서 1995년 1월과 1999년 1월의 2단계에 걸쳐 현재 적용 받고 있는 분진배출 규제치보다 훨씬 낮은 선진국 수준의 분진배출 규제가 요구되고 있으며, 분진이 배출되는 인근지역주민의 민원에 대처하기 위해서는 연돌로부터 분진배출이 눈에 감지되지 않을 정도까지 분진배출농도를 관리해야할 필요성이 높아지고 있다. 이에 따라 집진장치의 효율도 중유전소 Boiler 의 경우는 90% 이상, 석탄전소 Boiler의 경우는 99.5% 이상의 고효율이 요구되고 있다.

  • PDF

Prediction of Target Motion Using Neural Network for 4-dimensional Radiation Therapy (신경회로망을 이용한 4차원 방사선치료에서의 조사 표적 움직임 예측)

  • Lee, Sang-Kyung;Kim, Yong-Nam;Park, Kyung-Ran;Jeong, Kyeong-Keun;Lee, Chang-Geol;Lee, Ik-Jae;Seong, Jin-Sil;Choi, Won-Hoon;Chung, Yoon-Sun;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.132-138
    • /
    • 2009
  • Studies on target motion in 4-dimensional radiotherapy are being world-widely conducted to enhance treatment record and protection of normal organs. Prediction of tumor motion might be very useful and/or essential for especially free-breathing system during radiation delivery such as respiratory gating system and tumor tracking system. Neural network is powerful to express a time series with nonlinearity because its prediction algorithm is not governed by statistic formula but finds a rule of data expression. This study intended to assess applicability of neural network method to predict tumor motion in 4-dimensional radiotherapy. Scaled Conjugate Gradient algorithm was employed as a learning algorithm. Considering reparation data for 10 patients, prediction by the neural network algorithms was compared with the measurement by the real-time position management (RPM) system. The results showed that the neural network algorithm has the excellent accuracy of maximum absolute error smaller than 3 mm, except for the cases in which the maximum amplitude of respiration is over the range of respiration used in the learning process of neural network. It indicates the insufficient learning of the neural network for extrapolation. The problem could be solved by acquiring a full range of respiration before learning procedure. Further works are programmed to verify a feasibility of practical application for 4-dimensional treatment system, including prediction performance according to various system latency and irregular patterns of respiration.

  • PDF