Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

Evaluation of Difference between Skin Motion and Tumor Motion for Respiration Gated Radiotherapy (호흡조절방사선치료를 위한 피부움직임과 종양움직임 차이 평가)

  • Kwon, Kyung-Tae;Lim, Sang-Wook;Park, Sung-Ho;Kwon, Soo-Il;Shin, Sung-Soo;Lee, Sang-Wook;Ahn, Seung-Do;Kim, Jong-Hoon;Choi, Eun-Kyung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.14-20
    • /
    • 2008
  • Accounting for tumor motion in treatment planning and delivery is one of the most recent and significant challenges facing radiotherapy. The purpose of this study was to investigate the correlation and clarified the relationship between the motion of an external marker using the Real-Time Position Management (RPM) System and an internal organ motion signal obtained fluoroscope. We enrolled 10 patients with locally advanced lung cancer and liver cancer, retrospectively. The external marker was a plastic box, which is part of the RPM used to track the patient's respiration. We investigated the quantitatively correlation between the motions of an external marker with RPM and internal motion with fluoroscope. The internal fiducial motion is predominant in the caraniocaudal direction, with a range of $1.3{\sim}3.5cm$ with fluoroscopic unit. The external fiducial motion is predominant in the caraniocaudal direction, with a range of $0.43{\sim}2.19cm$ with RPM gating. The two measurements ratio is from 1.31 to 5.56. When the regularization guided standard deviation is from 0.08 to 0.87, mean 0.204 cm, except only for patients #3 separated by a mean 0.13 cm, maximum of 0.23 cm. This result is a good correlation between internal tumor motion imaged by fluoroscopic unit and external marker motion with RPM during expiration within 0.23 cm. We have demonstrated that gating may be best performed but special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct phase difference alone would not guarantee that the entire tumor volume is within the treatment field.

  • PDF

Performance Evaluation of the Tumor Tracking Method Using Beam on/off Interface for the Treatment of Irregular Breathing (호흡이 불규칙한 환자의 치료를 위한 Beam on/off Interface를 이용한 종양 추적 치료 방법의 성능 평가)

  • Lee, Minsik
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.343-349
    • /
    • 2018
  • Dose rate regulated tracking is known to be an efficient method which adaptively delivers tracking treatments when patient breathing is irregular. The Motion Management Interface (MMI, Varian Medical System, CA), which provides beam on/off switching during treatment is available for clinic. Study is to test if delivering the adaptive tumor tracking is feasible for irregular breathing using beam switching with MMI. 55 free breathing RPM traces acquired from lung cancer patients are used. The first day RPM traces of the patients are utilized to design preprogrammed tracking MLC patterns, of which periods are intentionally reduced by 20% in order to catch up the variation of patient breathing irregularity in the treatment day. Eligibility criteria for this technique are the variation of amplitude and period less than 20%. An algorithm which determines beam on/off every 100 ms by considering the preprogrammed (MLC) positions and current breathing positions is developed. Tracking error and delivery efficacy are calculated by simulating the beam-switching adaptive tracking from the RPM traces. Breathing patterns of 38 patients (70%) met the eligibility criteria. Tracking errors of all of the cases who meet the criteria are less than 2 mm (average 1.4 mm) and the average delivery efficacy was 71%. Those of rest of the cases are 1.9 mm and 48%. Adaptive tracking with beam switching is feasible if patient selection is based on the eligibility criteria.

Applying Inhaled Furosemide for Refractory Breathlessness in Terminally-ill Cancer Patients - Based on Seminar of Palliative Medicine Research Group, The Korean Academy of Family Medicine - (말기암환자에서 불응성 호흡곤란 완화를 위한 Furosemide 흡입치료 -대한가정의학회 완화의학연구회 세미나에 기초한-)

  • Hwang, In-Cheol;Lee, Min-Kyu;Kim, Kyoung-Kon;Lee, Kyoung-Sik;Suh, Heuy-Sun
    • Journal of Hospice and Palliative Care
    • /
    • v.13 no.4
    • /
    • pp.252-256
    • /
    • 2010
  • Breathlessness is a frequent and distressing symptom in terminal cancer patients. Refractory breathlessness is defined as a state that does not respond to conventional disease-specific therapy with an exclusion of reversible underlying causes, and the main classes of symptomatic drug treatments include opioids and benzodiazepines. Korean Family Medicine Palliative Medicine Research Group discussed two terminal cancer patients in whom severe breathlessness with different causes were treated with inhalation of nebulized furosemide, which is an emerging option of palliative treatment. It still remains unclear how it becomes effective or how much it is effective, therefore, its routine use seems to be somewhat early. Nevertherless, if a patient with intractable breathlessness does not have a marked obstructive airway lesion, its use should be considered. Based on the discussion in the seminar, we want to share our experience of the application of inhaled furosemide with other palliative care practitioners and strongly recommend further research on this topic in the future.

A Case of Obstructive Sleep Apnea Syndrome in Childhood (소아 폐쇄성 수면무호흡증후군 1례)

  • Lee, Seung-Hoon;Kwon, Soon-Young;Lee, Sang-Hag;Chang, Ji-Won;Kim, Jin-Kwan;Shin, Chol
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.1
    • /
    • pp.50-54
    • /
    • 2004
  • The obstructive sleep apnea syndrome can occur due to various etiologies in children. In otherwise healthy children, adenotonsillar hypertrophy is the leading cause of childhood obstuctive sleep apnea. Obstructive sleep apnea caused by adenotonsillar hypertrophy can lead to a variety of symptoms and sequelae such as behavioral disturbance, enuresis, failure to thrive, developmental delay, cor pulmonale, and hypertension. So if obstructive sleep apnea is clinically suspected, proper treatment should be administered to the patient after diagnostic examinations. More than 80% improvement is seen in symptoms of obstructive sleep apnea caused by adenotonsillar hypertrophy in children after tonsillectomy and adenoidectomy. However, when it is impossible to treat the patient using surgical methods or residual symptoms remained after tonsillectomy and adenoidectomy, additional treatments such as weight control, sleep position change, and continuous positive airway pressure (CPAP), should be considered. This paper reports a case using weight control and Auto-PAP to control mild sleep apnea and snoring, which in long-term follow-up were not resolved after tonsillectomy and adenoidectomy for severe obstructive sleep apnea.

  • PDF

세기조절방사선치료 조사면의 최소 조각 크기에 대한 치료중 표적 움직임의 효과

  • 서예린;이병용;안승도;이상욱;김종훈;신성수;신승애;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.37-37
    • /
    • 2003
  • 목적 : 일반적으로 세기조절방사선치료 조사면의 작은 조각 크기에 대해, 이상적인 플루언스 지도 혹은 치료계획장치로부터의 최적화된 결과에 가까운 선량분포에서 더 좋은 leaf sequence를 얻을 수 있다. 한편, 치료중 장기의 움직임이 가장 작은 조각 크기의 선택을 방해하는 문제는 항상 존재한다. 게다가, 전통적인 정지 조사면과 달리 표적이 움직이는 동안 조사면 자체도 움직이므로 움직이는 표적에 대한 세기조절방사선치료의 경우에서 적절한 표적 마진에 관한 질문이 제기되어왔다. 따라서, 이 연구에서는 조각 크기에 대한 치료중 표적 움직임의 효과를 연구하였다. 대상 및 방법 : 세기조절방사선치료 플루언스 지도에 대해, 다양한 크기 - 0.5$\times$0.5, 1.0$\times$1.0, $1.5\times$1.5, 2.0$\times$2.0, 3.0$\times$3.0, 4.0$\times$4.0, 5.0$\times$5.0 $ extrm{cm}^2$ - 의 정사각형 패턴들을 설계하였고, Leaf sequence 는 step-and-shoot 빔 전달 방법을 이용하였다. 인접 조각들 사이의 세기 비율은 0.2, 0.4, 0.6, 0.8, 1.0로 하였고, 표적 움직임은 범위가 0.5-2.0 cm인 사인곡선 형태로 가정하였다. 움직임 묘사를 위해 동적 leaf 의 움직임이 표적의 움직임 을 반영하도록 계산되었고 움직임의 효과를 분석하기 위해 필름선량측정을 수행하였다. 결과 : 인접 조각의 세기 비율은 모든 경우에서 저하되었고, 호흡 진폭의 반보다 작은 조각 크기에 대한 선량분포는 임상적으로 유의할만큼 저하된 세기 지도를 보였다. 조각에 대해 방사선 조사시간의 두 호흡주기이상에 대해서는, 표적 마진 주위의 선량분포가 통상적인 정지 조사면에서와 같았다. 결론 : 플루언스 지도에서 세기조절방사선치료 조각의 최소 크기는 치료중 장기 움직임을 고려한 후 선택되어야 한다. 조각에 대한 방사선 조사시간의 두 호흡주기이상에 대해서는, 표적 마진을 기존의 정지 조사면과 같게 정의할 수 있었다.

  • PDF

Sepsis (패혈증)

  • Kim, Jae Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.1
    • /
    • pp.13-16
    • /
    • 2007
  • 현 상태에서 패혈증에서 최선의 치료는 조기, 목표지향치료, 저일호흡량을 포함한 폐 보호 기계환기, 그리고 activated protein C 등을 들 수 있으며, 코티코스테로이드 치료나 적극적인 인슐린 치료법에 대해서는 아직 치료효과가 검증되지 않은 상태이다. 전통적으로 시행되고 있는 조기에 광범위한 항생제 투여, 창상의 치료 등은 한상 강조되어야 할 치료 방법이다.

Quantitative Evaluation of Gated Radiation Therapy Using Gamma Index Analysis (감마지표 분석을 통한 호흡연동방사선치료의 정량적 평가)

  • Ma, Sun Young;Choi, Ji Hoon;Jeung, Tae Sig;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.198-203
    • /
    • 2013
  • Generally, to evaluate gated radiation therapy, moving phantoms are used to simulate organ motion. Since the target moves in every direction, we need to take into account motion in each direction. This study proposes methods to evaluate gated radiation therapy using gamma index analysis and to visualize adequate gating window sizes according to motion ranges. The moving phantom was fabricated to simulate motion in the craniocaudal direction. This phantom consisted of a moving platform, the I'm MatriXX, and solid water phantoms. A 6 MV photon filed with a field size of $4{\times}4cm^2$ was delivered to the phantom using the gating system, while the phantom moved in the 1-, 2-, 3-, 4-, and 5-cm motion ranges. The gating windows were set at 40~60%, 30~40%, and 0~90%, respectively. The I'm MatriXX acquired the dose distributions for each scenario and the dose distributions were compared with a $4{\times}4cm^2$ static filed. The tolerance of the gamma index was set at 3%/3 mm. The greater the gating window, the lower the pass rate, and the greater the motion range, the lower the pass rate in this study. In case treatment without gated radiation therapy for the target with motion of 2 cm, the pass rate was less than 96%. But it was greater than 99% when gated radiation therapy was used. However gated radiation therapy was used for the target with motion greater than 4 cm, the pass rate could not be greater than 97% when gating window was set as 30~70%. But when the gating window set as 40~60%, the pass rate was greater than 99%.

The Effect of Nasal CPAP in Obstructive Sleep Apnea Syndrome (폐쇄형 수면무호흡증후군 환자에서 Nasal CPAP의 치료 효과)

  • Kim, Chi-Hong;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.501-508
    • /
    • 1993
  • Background: Sleep apnea syndrome is a common disorder which is estimated to affect about 1~4% of adult male population. And if untreated, sleep apnea can cause significant sequelae, such as hypertension, nocturnal cardiac arrhythmia, daytime hypersomnolence, and cognitive impairment. Various kinds of treatment for obstructive sleep apnea (OSA) have been developed. Among them nasal CPAP, first introduced by Sullivan et al in 1981, has received widespread interest and acclaim as a treatment of OSA, and is currently recommended as first-line treatment for OSA. We evaluated the effect of nasal CPAP in OSA and the side effects of nasal CPAP hindering patients from using nasal CPAP. Methods: We performed sleep studies in 20 OSA patients at 2 consecutive nights; baseline night at first day and CPAP night at second day. We compared apnea index, lowest oxygen concentration during apnea, maximal apnea time, and total apnea duration per total sleep time before and after CPAP. We also evaluated the side effects of CPAP with inquiry to the patients. Results: 1) Apnea index was significantly decreased after CPAP in 17 out of 20 OSA patients (85%) and increased in 3 patients (15%). 2) Average apnea index was significantly decreased after CPAP ($34.1{\pm}18.9/h{\rightarrow}15.4{\pm}10.3/h$, p<0.01). 3) Total apnea duration per total sleep time was also significantly decreased after CPAP ($28.5{\pm}16.0%{\rightarrow}11.9{\pm}9.3%$, p<0.05). 4) The lowest oxygen satuation and maximal apnea time were not significantly changed after CPAP. 5) The most frequent side effect of nasal CPAP was mask discomfort (80%), and the next was drying of nasal passages (65%). Conclusion: Nasal CPAP is an effective treatment for OSA. Futher studies should be concentrated on long term follow up of nasal CPAP for its therapeutic effects and the study of methods to enhance patients' compliance.

  • PDF

Amiodarone-Induced ARDS after MVR -A case report- (승모판치환술 후에 발생한 아미오다론에 의한 급성호흡곤란증훈군 -1례 보고-)

  • 이기복;김응중;지현근;신윤철
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.594-598
    • /
    • 2002
  • Amiodarone is an iodinated benzofuran derivative that has been proved effective in the control of supraventricular and ventricular arrhythmias refractory to other antiarrhythmic drugs. In patients treated with amiodarone, subsequent surgical intervention is a common clinical scenario, but unfortunately we do not have definite data about complications due to amiodarone after cardiac surgery. Some reports have shown that amiodarone treatment can be associated with a state of $\alpha$-adrenergic and $\beta$-adrenergic receptor blockade, which requires more pacing and epinephrine infusion for perioperative hemodynamic support. And some reports have also identified a severe form of ARDS in patients on amiodarone therapy which was associated with siginificant morbidity and mortality. We exprienced a patient who expired after mitral valve replacement due to amiodarone-induced ARDS; therefore, we report this case with a brief literature.