1 |
H. Kubo, B. C. Hill, “Respiration gated radiotherapy treatment: a technical study,” Physics in Medicine and Biology, Vol. 41, No. 1, pp. 83-91, 1996.
DOI
|
2 |
D. Mah, J. Hanley, K. E. Rosenzweig, E. Yorke, L. Braban, C. C. Ling, S. A. Leibel, G. Mageras, “Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer,” International Journal of Radiation Oncology Biology Physics, Vol. 48, No. 4, pp. 1175–1185, 2000.
DOI
|
3 |
V. M. Remouchamps, F. A. Vicini, M. B. Sharpe, L. L. Kestin, A. A. Martinez, J. W. Wong, "Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation," International Journal of Radiation Oncology Biology Physics. Vol. 55, No. 2, pp. 392-406, 2003.
DOI
|
4 |
S. B. Jiang, “Technical aspects of image-guided respiration-gated radiation therapy,” Medical dosimetry, Vol. 31, No. 2, pp. 141-151, 2006.
DOI
|
5 |
P. J. Keall, H. Cattell, D. Pokhrel, S. Dieterich, K. H. Wong, M. J. Murphy, S. S. Vedam, K. Wijesooriya, R. Mohan, “Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system,” International Journal of Radiation Oncology Biology Physics, Vol. 65, No. 5, pp. 1579-1584, 2006.
DOI
|
6 |
C. Shi, N. Papanikolaou, "Tracking versus Gating in the Treatment of Moving Targets," European Oncological Disease, No. 1, pp. 83-86, 2007.
|
7 |
S. Oh, B. Yi, B. L. Berman, F. Lerma, C, Yu, "Accuracy of dose-rate-regulated tracking: a parametric study," Physics in Medicine and Biology, Vol. 55, pp. 1-13, 2010.
DOI
|
8 |
I. Buzurovic, K. Huang, Y. Yu, T. K. Podder, "A robotic approach to 4D real-time tumor tracking for radiotherapy," Physics in Medicine and Biology, Vol. 56, pp. 1299-1318, 2011.
DOI
|
9 |
S. Oh, B. Yi, F. Lerma, B. Berman, M. Gui, C. Yu, “Verification of MLC based real-time tumor tracking using an electronic portal imaging device,” Medical Physics, Vol. 37, No. 6, pp. 2435-2440, 2010.
DOI
|
10 |
A. Sawant, R. L. Smith, R. B. Venkat, L. Santanam, B. Cho, P. Poulsen, H. Cattell, L. J. Newell, P. Parikh and P. J. Keall, “Toward submillimeter accuracy in the management of intrafraction motion: the integration of real-time internal position monitoring and multileaf collimator target tracking,” International Journal of Radiation Oncology*Biology*Physics, Vol. 74, No. 2, pp. 575-582, 2009.
DOI
|
11 |
Varian Medical Systems, Clinac 3rd Party External System Interface: Version 2, December 2005.
|
12 |
P. J. Keall, G. S. Mageras, J. M. Balter, R. S. Emery, K. M. Forster, S. B. Jiang, J. M. Kapatoes, D. A. Low, M. J. Murphy, B. R. Murray, C. R. Ramsey, M. Herk, S. Vedam, J. Wong, E. Yorke, “The management of respiratory motion in radiation oncology report of AAPM Task Group 76,” Medical Physics, Vol. 33, No. 10, pp. 3874-4774, 2006.
DOI
|
13 |
B. Yi, S. Oh, B. Berman, F. Lerma, C. Yu, “Real-time tumor tracking with preprogrammed dynamic multileaf collimator motion and adaptive dose-rate regulation,” Medical Physics, Vol. 35, No. 9, pp. 3955-4017, 2008.
DOI
|
14 |
L. Papiez, R. Abolfath, “Variable beam dose rate and DMLC IMRT to moving body anatomy,” Medical Physics, Vol. 35, No. 11, pp. 4837-4885, 2008.
DOI
|