• Title/Summary/Keyword: 형광 이미지

Search Result 75, Processing Time 0.03 seconds

Development of An Integration Management System of Analyzing Fluorescence Images on Smart Phone (모바일용 형광이미지 분석 통합관리 시스템 개발)

  • Cho, Mi-Gyung;Shim, Jae-Sool
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.916-919
    • /
    • 2012
  • Bioimaging that can be imaging phenomena within cells of a molecular size have been advanced in technology. We can observe clearly DNA and proteins using a confocal microscope. Currently biological fluorescent imaging area is used essentially for diagnosis and treatment in health and clinical care field. In this paper, we developed an integration management system of analyzing fluorescence images on smart phone. It can support a user to analyse fluorescence images anytime anywhere. And our system is based on client-server configuration and has functions that can figure intensity of fluorescence images and manage many imaging data. Proposed system can be a mean of ubiquitous health because it helps a doctor diagnose by analyzing fluorescence images of emergency patients without time and space restrictions.

  • PDF

Development of a real-time Analysis System of Microchip Fluorescence Images based on Server-Client (서버 클라이언트 기반의 실시간 마이크로칩 형광 이미지 분석 시스템 개발)

  • Cho, Migyung;Shim, Jaesool
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1239-1244
    • /
    • 2013
  • In the field of clinical medicine and research, the analysis of such as protein and DNA at the molecular level and even at the cell level are necessary for disease diagnosis and treatment. In many cases, a real time image of samples is needed for the accurate analysis and manipulation of samples since experimental samples are degenerated with time. In this research, a three-dimensional fluorescence microscope device was developed for taking images of protein and DNA inside a single cell and the server-client based image analysis system was made for an integrated management of the real-time images taken from the microscope device. The system consists of a fluorescent measurement device, the associated software and a client program on smartphone. The developed system allows doctors or experimental managers to receive and look at the real-time experimental images taken from the samples of patients anywhere in the emergency, to analyze results and to instantly diagnose the disease and to transfer the results to the patients. As a result, the system is able to be utilized in the implementation of ubiquitous health as well.

Automated Bacterial Cell Counting Method in a Droplet Using ImageJ (이미지 분석 프로그램을 이용한 액적 내 세포 계수 방법)

  • Jingyeong Kim;Jae Seong Kim;Chang-Soo Lee
    • Korean Chemical Engineering Research
    • /
    • v.61 no.2
    • /
    • pp.247-257
    • /
    • 2023
  • Precise counting of cell number stands in important position within clinical and research laboratories. Conventional methods such as hemocytometer, migration/invasion assay, or automated cell counters have limited in analytical time, cost, and accuracy., which needs an alternative way with time-efficient in-situ approach to broaden the application avenue. Here, we present simple coding-based cell counting method using image analysis tool, freely available image software (ImageJ). Firstly, we encapsulated RFP-expressing bacteria in a droplet using microfluidic device and automatically performed fluorescence image-based analysis for the quantification of cell numbers. Also, time-lapse images were captured for tracking the change of cell numbers in a droplet containing different concentrations of antibiotics. This study confirms that our approach is approximately 15 times faster and provides more accurate number of cells in a droplet than the external analysis program method. We envision that it can be used to the development of high-throughput image-based cell counting analysis.

A Study on the Development of Quantitative Analysis Methods to Characterize the Transport of Microplastics in Saturated Porous Media (포화 다공성 매체에서 미세플라스틱 이동 특성 규명을 위한 정량분석 방법 개발 연구)

  • Suhyeon Park;Minjune Yang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.376-376
    • /
    • 2023
  • 전 세계적으로 중요한 담수 자원인 지하수의 미세플라스틱 오염에 대한 우려가 커지고 있다. 지하수 환경에서 미세플라스틱의 오염을 예측하고 평가하기 위해 대수층 내 현장 실태조사가 수행 중에 있으며, 실험실 규모의 컬럼 실험을 통해 지하수에서 미세플라스틱 이동 메커니즘을 조사하는 연구들이 수행되고 있다. 이러한 연구들은 많은 개수의 분석 시료를 동반하며, 환경 중 미세플라스틱 정량분석을 위해서 고가의 분석기기(라만분광기, 푸리에 변환 적외선(FTIR) 분광기, 열분해 가스크로마토그래피 질량분석기)를 사용하여 플라스틱의 종류를 판별하고 개수를 측정하고 있다. 또한, 컬럼 실험을 수행한 대부분의 선행 연구에서는 미세플라스틱 정량분석을 위해 탁도 분석, 분광광도계를 이용한 흡광도 분석, 현미경을 이용한 계수 방법 등을 이용하여 고가의 분석기기를 사용하지 않고 연구를 수행하였다. 하지만, 이러한 방법들은 유체 속 다른 물질이 포함되어있을 경우에 민감하고 농도를 비율 혹은 개수로 표현하기 때문에 질량 측면에서 미세플라스틱의 농도를 과소·과대 평가할 수 있다. 특히, 현미경을 이용한 계수 방법의 경우에는 분석에 많은 시간이 소요된다는 단점이 있다. 위에 언급한 다양한 분석법들의 단점들을 보완하기 위하여, 본 연구에서는 대수층 내 미세플라스틱 이동 특성을 규명하기 위한 실내 실험에 사용될 수 있는 형광이미지 기반의 미세플라스틱 정량분석법을 개발하였다. Nile Red 형광염료를 이용하여 미세플라스틱을 염색하고 사진을 촬영하여 미세플라스틱 시료의 질량과 미세플라스틱 형광이미지의 형광강도 간 상관관계를 분석하였다. 또한, Nile Red로 염색된 미세플라스틱 입자의 수중 노출 테스트를 진행하여, 실내 대수층 모의실험 시 미세플라스틱 질량을 정량화할 수 있는 적용 가능성을 평가하였다. 상관 분석 결과, 미세플라스틱 질량과 이미지의 형광강도는 높은 상관관계를 보였으며, 수중 노출 실험 전과 후의 미세플라스틱 입자의 형광강도 차이는 미미한 것으로 나타났다. 이러한 연구결과를 통해 본 연구에서 개발된 미세플라스틱 정량분석 방법이 포화 다공성 매체로 구성된 컬럼실험 시 유출수의 미세플라스틱 질량 추정에 유용하게 사용될 것으로 생각되며, 대수층 내 미세플라스틱의 이동 특성 규명 연구에 많은 도움이 될 것으로 기대된다.

  • PDF

Identification of natural colored diamonds using UV fluorescent and X-ray Lang images (UV 형광과 X-선 Lang 표면이미지를 이용한 천연유색다이아몬드의 감별 연구)

  • Kim, Jun-Hwan;Ha, Jun-Seok;Kim, Ki-Hoon;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3540-3545
    • /
    • 2009
  • Due to recent development of high temperature high pressure(HTHP) diamond synthetic and treatment technology, we need to identify the natural diamonds fast, reliable, and economically. We proposed using new method of UV fluorescence and X-ray Lang topography imaging for distinguishing one synthetic diamond from four natural colored diamonds. We observe unique local stress field uneven image in synthetic diamond using UV fluorescence and Lang topography characterization, while uniform images in natural diamonds. Especially, X-ray Lang method offered the better identification power with better high resolution on stress field images.

Measurement of the fuel distribution in a scaled ATR combustor using PLIF (PLIF를 이용한 ATR 연소기 축소모형의 연료분포 측정연구)

  • Jin Yu-In;Yang In-Young;Choi Young-Hwan;Yang Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.4
    • /
    • pp.55-65
    • /
    • 2005
  • Mixing performance between fuel and oxidizer is a significant parameter of combustion efficiency and stability in an air-turbo ramjet combustor. Two types of petal mixer were experimented to research the mixing performance. Mixing performance and fuel distribution images were obtained for petal mixers. Planar laser-induced fluorescence(PLIF) was used to obtain 2-D fuel distribution. The obtained images were processed in order to make use of the image information to a quantitative level. The results of analyzing the fluorescence images could be useful to find better mixing performance between mixers.

Fluorescence Characteristic Analysis for Fiber Detection in Sectional Image of Fiber Reinforced Cementitious Composite (섬유 보강 시멘트계 복합재료의 단면 이미지에서 섬유 검출을 위한 섬유 형광 특성 분석)

  • Lee, Bang-Yeon;Park, Jun-Hyung;Kim, Yun-Yong
    • Composites Research
    • /
    • v.23 no.3
    • /
    • pp.50-57
    • /
    • 2010
  • It is important to detect fibers in the sectional image of fiber reinforced cementitious composites (FRCC), since the fiber distribution is a crucial factor to predict or evaluate the mechanical performance of FRCC. In this paper, we investigated the fluorescence characteristics of Polyvinyl Alcohol (PVA) fibers, Polyethylene Terephthalate (PET) fibers, Polyethylene (PE) fibers, and Polypropylene (PP) fibers used in Engineered Cementitious Composites (ECC), which is a special kind of FRCC that incorporates synthetic fibers and exhibits extremely ductile behavior in uniaxial tension, to detect each fiber according to its type. Furthermore, optimum excitation and emission wavelengths were proposed on the basis of maximum difference of Relative Fluorescence Intensity (RFI) between two types of fibers used in the hybrid ECC. Optimum threshold values to discriminate two types of fibers using statistical tools were also proposed. Finally, images of four types of fibers obtained using a fluorescence microscope are compared.

Salt Tolerance Assessment with NaCl of Stauntonia hexaphylla (Thunb.) Decene. and Raphiolepis indica var. umbellata (Thunb.) Ohashi (NaCl 처리에 따른 멀꿀과 다정큼나무의 내염성 평가)

  • Choi, Su Min;Shin, Hyeon Cheol;Kim, Inhea;Huh, Keun Young;Kim, Daeil
    • Horticultural Science & Technology
    • /
    • v.31 no.5
    • /
    • pp.617-625
    • /
    • 2013
  • Stauntonia hexaphylla and Raphiolepis indica, cold-tolerant broadleaved evergreens ranging through the southern region of South Korea, were assessed on salt tolerance with NaCl treatment using visual damage, chlorophyll florescence image, and malondialdehyde (MDA) analysis. As NaCl concentrations increased, the soil pH decreased and EC increased, and the soil of S. hexaphylla was affected more strongly by the treatment than that of R. indica. In visual damage, S. hexaphylla withered above 200 mM NaCl at 20 days after the treatment. All individuals of R. indica survived during the experiment though the leaves of R. indica showed visual damages up to 400 mM NaCl. The color changes in chlorophyll fluorescence showed a strong correlation with the degree of visual damage. As NaCl increased, the red color of the leaves of S. hexaphylla was distinctly changed to blue and chlorophyll fluorescence decreased starting from the margin to the middle of a leaf. R. indica showed subtle color changes and remained in red color during the experiment. At five days after the NaCl treatment, the MDA of S. hexaphylla was above $4.56nmol{\cdot}g^{-1}$ when plants showed the highest visual damage and EC. The MDA of R. indica in all treatments showed below $1.5nmol{\cdot}g^{-1}$ except 400 mM NaCl treatment during the experiment.

image processing and development of digital X-ray using CCD Camera (CCD 카메라를 이용한 디지털 X-ray개발과 영상처리에 관한 연구)

  • Jeong, Jae-Sang;Gang, Yong-Cheol;HwangBo, Soung
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2795-2797
    • /
    • 2003
  • 기존의 X-ray System을 보면 방사선 소스와 방사선을 가시광선으로 변환시키는 형광판, 그리고 이 발광된 빛을 증폭시키는 작용을 하는 영상 증배관과 필름으로 구성된다. 이에 따른 시스템의 부피와 한 장의 필름이 나오기까지의 과정 등이 매우 번거롭다. 이 시스템을 저비용의 디지털 X-ray 시스템으로 대체함에 있어서 형광판과 디지털 CCD카메라를 이용하여 저가이면서 시스템 자체는 간소화시킨 X-ray시스템을 개발하고자한다. X-ray이미지는 형광판의 밀도와 카메라의 분해능에 따라 그 해상도가 결정이 되지만, 이번연구에서는 8bit의 분해능에 $1300{\times}1030$의 해상도를 갖는 Monochrome Digital 카메라를 사용하고, 기존 시스템에 사용되던 간접촬영용 형광판을 사용하였다. 기존시스템의 영상증배관을 배제시켜 후처리에 중점을 두어 시스템은 간소화하고, 저비용을 실현시켰다.

  • PDF

Heavy Metal Ion Detection in Living Cell Using Fluorescent Chemosensor (형광화학센서를 이용한 살아있는 세포 내에서의 중금속이온검출)

  • Kwon, Pil-Seung;Kim, Jin-Kyung;Kim, Jong-Wan
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.4
    • /
    • pp.451-459
    • /
    • 2010
  • The fluorescence detection of intracellular metal ions are high interest in the fields of organic molecular chemistry and cellular biology. This study was purposed to detection for mercury and zinc in the cell using fluorescent chemosensor (FS). FS exhibits a weak fluorescence, but emits strong fluorescence upon Zn$^{2+}$ complexation. The increased fluorescence of the 2FS/Zn$^{2+}$ can be quenched completely by addition of only 1 equiv of Hg$^{2+}$ with the formation of complex FS-Hg$^{2+}$. Four cell lines (LLC-MK2, Hela, HT29 and AMC-HN3) were used for fluorescence imaging by confocal microscope. The cell viability MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was evaluated after cell treatment of FS, Zn$^{2+}$, FS-Zn$^{2+}$, Hg$^{2+}$ on LLC-MK2 cell line. The cytotoxicity of FS was showed to viability over 80%. This study has shown that FS can be detected for selective imaging of Zn$^{2+}$ and Hg$^{2+}$ in living cells.