• Title/Summary/Keyword: 현장모의시험

Search Result 73, Processing Time 0.027 seconds

A Study on Constructability Estimation of Multi-component High Fluidity Concrete based on Mock-up Test (모의실험체에 의한 다성분계 고유동 콘크리트의 시공성능 평가에 관한 연구)

  • Kwon, Ki-Joo;Noh, Jea-Myoung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.75-82
    • /
    • 2010
  • As structures become larger, taller, and more diverse, a high degree of technology and expertise are required in the construction industry. However, it has been becoming difficult to construct under severe conditions and to fulfill the high performance needs of structures due to a lack of skilled construction engineers. To compensate for these weak points, high-performance concrete and performance specifications have been developed. The application of reliable high-fluidity concrete, which is one of these efforts, is expected to be effective in terms of overcoming severe conditions, reducing the number of workers required, and shortening the construction period. In order to apply high fluidity concrete in the field, practical mock-up tests were carried out to estimate whether self-compaction concrete could satisfy constructability needs. From the results, it was verified that the multi-component high fluidity concrete has excellent flowability in practical structures. In addition, it was shown that the temperature distribution in the concrete due to hydration heat is satisfactory. As a result, it is judged that multi-component high fluidity concrete can be utilized as an effective building material for various structures, including structures related to the electric power industry.

The development of multi-loop generator control system with IGBT converter (IGBT를 이용한 디지털 다중화 발전기 제어시스템 개발)

  • Lee, J.H.;Ryu, H.S.;Sin, M.S.;Lim, T.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2266-2268
    • /
    • 2004
  • 전력수요의 증대로 발전기 전압제어를 통해 전력계통의 안정과 양질의 전력공급의 중요한 역할을 하는 여자시스템의 중요성이 한층 더 증대되었다. 본 논문은 선진 외국 제작사 기술에 전적으로 의존하고 있는 발전기 제어시스템을 순수 국내기술로 개발하여 교체하기 위해 제어시스템의 개발내용과 모의시험 및 현장 적용을 통한 시험 및 성능을 평가한 내용을 기술하였다.

  • PDF

Research of KNPEC-2 Simulator Upgrade(I) (원자력 교육원 #2 시뮬레이션 성능개선에 관한 연구(I))

  • 유현주
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.249-252
    • /
    • 2000
  • 원자력 교육원 #2(KNPEC-2) 시뮬레이터는 1980년도 중반에 웨스팅하우스에 의해 공급되어 계속 사용되어 오다가 현재 성능개선 연구가 진행 중이다. 이번 성능개선을 통해 기존의 컴퓨터 시스템(Gould MPX)와 소프트웨어의 전면 교체가 이루어지고 있으며 최적 계산 코드를 이용한 실시간 열수력 모델 (ARTS; Advanced Real-Time Thermal-Hydraulics Simulation) 개발 , 2-Group 3D 실시간 노심모델(REMARK ; REal Time Multigroup Advanced Reactor Kinetics)를 이용한 노심 주기개선 (Cycle Update) 가상현실 기술 등을 이용한 컴퓨터 교육지원 시스템(CATS: Computer Assister Training System)등 새로운 시도가 이루어지고 있으며 본 논문은 이러한 새로운 시도가 이루어지고 있으며 본 논문은 이러한 새로운 시도들 및 그 결과에 대해 기술하고 있다. 기준발전소(Reference Plant)인 영광 1호기 12주기의 노심모델로 주기개선(Cycle Update)을 위한 REMARK의 입력자료 생성을 위해 핵설계 전산체계인 APA(ALPHA-PHOENIX-ANC) 시스템의 출력으로부터 자동으로 REMARK 입력데이타를 생성하기 위한 GUI툴 개발하였다. 또 이를 이용하여 개발된 노심모델은 최적계산코드(RETRAn 3D) 의 열수력 해법을 이용하여 개발된 NSSS 열수력코드(ARTS) 와 결합(Integration) 되어 안정 및 과도 상태 시험에 사용되었으며 원자로 냉각재 펌프 정지등의 몇 가지 과도 시험 계산결과 기존 해석 결과와 잘 일치하였다 중앙제어실(MCR; Main Control Room)내의 운전원 행동만 훈련하도록 되어있는 기존시뮬레이터의 한계를 극복하기 위해 가상현실 (VR) 저작도구를 이용한 발전소 현장 내부를 표현하는 가상발전소 (Virtual Plant) 발전소 현장에 소재하여 기존 시뮬레이터의 모의한계 밖에 있던 패널을 표현한 가상판넬(Virtual Panel)등과 강의실에서 발전소 모의 훈련을 가능케 하기 위해 가상현실 기술을 이용한 컴퓨터 지원 교육훈력 시스템(CATS ; Computer Assister Training System)을 개발 중이며 일부 개발부분을 소개하였다.

  • PDF

A Study on Properties of Early Strength Development of the Concrete (콘크리트의 조기강도 발현특성에 관한 연구)

  • Kang, Chang-Woon;Lee, Jae-Sam;Kim, Jung-Sik;Sung, Yong-Hwan;Ryu, Deug-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.541-544
    • /
    • 2008
  • Recently, due to the increase of high-rise buildings construction, many researches for making harden of concrete earlier and remove of forms faster are being performed to reduce construction period. The purpose of this study is to analysis which mixing condition and curing temperature of early strength concrete. Porperties of concrete by the different factors, such as the type of active admixtures, mineral admixtures, curing temperature, the amount of binder, etc. Through the test of concrete using the different type of admixture, PC type was more excellent than PNS type admixture. The concrete Strength remarkably will be able to confirm that decreases from temperature below 12$^{\circ}C$.

  • PDF

Study on Surge Response Characteristics and Surge Current Reduction for 154kV Shunt Capacitor Bank (154kV SC Bank의 써지 응답특성과 써지전류 저감에 관한 연구)

  • Hur, Yong-Ho;Choi, Myung-Kuk;Lee, Sang-Il;Jung, Jea-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.329-334
    • /
    • 2002
  • 우리나라 전력계통의 특성상 남부의 전원단과 수도권의 부하중심단과의 거리가 존재하여 안정적인 계통전압제어에 어려움이 존재한다. 이러한 계통전압제어의 어려움을 극복하기 위해 154kV 계통에 SC Bank를 설치 운용중에 있다. 운전 환경상 차단기의 투입과 차단이 잦은 154kV SC Bank에 리액터가 소손되는 등의 문제점이 발생하고 있어 154kV SC Bank의 써지응답특성을 규명하고 차단기의 투입차단시 발생하는 써지전류의 저감에 대한 연구의 필요성이 대두되고 있다. 본 연구에서는 154kV SC Bank를 대상으로하여 현장조사와 현장실증을 통해 써지전류를 측정하고, 모의를 통해 써지응답특성을 규명하였다. 그 결과, 차단기의 접점의 상태와 피뢰기의 동작여부에 의해 써지전류가 크게 영향을 받는다는 점을 확인하였다. 154kV SV Bank를 대상으로 한 현장시험과 서지응답특성의 분석결과를 기본으로 하여 피뢰기의 영향과 차단기의 투입차단 영향을 최소화하는 방안으로 피뢰기의 분리운전으로 전류재단현상을 막아 급준써지전류의 발생을 억제하고 저항투압방식의 차단기로 써지전류를 30%이하로 억제할 수 있음을 실증과 모의로 확인하였다.

  • PDF

Development of Longtime Reliability Assessment Method of Polymer Housed Distribution Surge Arresters using Accelerated Aging Test (가속열화시험을 이용한 배전용 폴리머피뢰기의 장기신뢰성 평가기법 개발)

  • Kim, Ju-Yong;Song, Il-Keun;Moon, Jae-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.141-150
    • /
    • 2006
  • In this study we developed accelerated aging test cycle and equipment which can simulate domestic weather condition. And we proposed long term reliability assessment method for polymer housed distribution surge arresters. We carried out electrical and chemical analysis of the arresters which are used for accelerated aging test and outdoor exposure test. Through the analysis we verified the capability of the proposed method and we presented characteristic data for maintenance of domestic arresters.

A Numerical evaluation of Constant Head Injection Test (수치 모사를 이용한 정압주입시험)

  • Park, Kyung-Woo;Kim, Kyung-Su;Koh, Yong-Kwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1918-1923
    • /
    • 2009
  • 결정질 암반에서 지하수의 수리적 특성을 파악하기 위해 수행되고 있는 수리시험 방법은 정률법, 정압법, 순간주입(회복)법 등 세 가지로 구분할 수 있다. 본 연구에서 다루는 정압주입시험 (Constant Head Injection Test, CHIT)은 위의 정압법의 한 종류로 토목공학, 지질공학 분야에서 대상 구간의 투수계수 추정을 위해 널리 쓰이는 수리 시험이며, 이는 단일 패커나 이중패커를 이용하여 시험 구간을 격리하고, 격리된 구간에 일정한 압력으로 물을 주입하여 주입되는 물의 양을 파악함으로써, 시험 구간의 수리전도도(Hydraulic conductivity)를 산출하는 전통적인 수리시험이다. 본 연구에서는 수치실험을 통해 시험 구간 및 주입 압력의 크기 등 인위적인 요인에 의해 도출되는 투수계수가 어떻게 달라지는지에 대해 평가해 보았다. 일반적으로 단열 암반에서 수행한 정압주입시험의 해석에 있어 매질을 균질, 등방성 다공질이라는 가정으로 구간별 투수량계수를 산출하기 때문에, 다공성 매질의 지하수 유동을 모사하는 MODFLOW를 수치모사 코드로서 이용하였다. 시험구간의 크기 및 주입압력에 대한 민감도 분석 결과, 시험구간의 크기에 상관없이 수치모의에서 입력한 수리전도도 값에 비해 낮은 수리전도도 값이 산출되었으며, 주입 압력이 클수록 산출되는 수리전도도 값이 매질의 수리전도도 값과 차이가 났다. 민감도 분석 결과 현장수리시험에서 정압 주입시험에 의한 구간별 수리전도도 산출함에 있어 시험구간의 크기와 주입 압력 값에 대하여 고려해야 한다고 판단된다.

  • PDF

Experimental Simulations of Borehole Breakouts and Their Relationship to In Situ Stress Magnitudes (시추공벽 파쇄 모의 시험 및 현장 응력과의 관계 연구)

  • 송인선
    • The Journal of Engineering Geology
    • /
    • v.10 no.3
    • /
    • pp.225-236
    • /
    • 2000
  • We conducted laboratory simulations of deep vertical drilling into the earth's crust to induce borehole breakouts and investigated their potential use for estimating in situ stress magnitudes in Westerly granite and Berea sandstone. Our experiments consisted of two major stages, a series of triaxial tests and borehole-breakout formation tests under a wide range of far-field stresses. We derived the Mohr-Coulomb, Nadai and Mogi failure criteria from the triaxial test results. Each criterion was compared with the stress condition at breakout boundaries. We concluded that the well known Mohr-Coulomb criterion is not compatible with the stress condition at breakout failure. On the other hand, polyaxial (truly triaxial) failure criteria such as the Nadai criterion for Berea sandstone and the Mogi criterion for Westerly granite were much more suitable for predicting breakout failure zone. Such failure criteria appeared to enable the reliable estimation of the magnitude of one of two horizontal principal stresses if the other one is known.

  • PDF

A Verification Study on Annual Deterioration of Distribution Polymeric Insulators (배전용 폴리머애자의 경년열화 실증연구)

  • Lee, J.B.;Song, I.K.;Lee, B.S.;Choi, S.K.;Kwon, T.H.;Jang, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.131-133
    • /
    • 2003
  • 폴리머애자는 기존 자기애자에 비하여 많은 장점을 가지고 있어 세계적으로 사용량이 증가하고있다. 그러나 폴리머재질을 사용함으로써 열화과정을 거치게 되어 있다. 폴리머애자의 장기신뢰성 및 수명 예측을 위하여 븐 연구에서는 복합가속열화시험장치에 의한 모의 열화시험, 현장 애자의 주기적인 발취 시험, 옥외 실증시험장에서의 애자상태 감시 둥을 통하여 폴리머애자의 장기신뢰성을 검증할 계획이다. 또한 새로운 장기 신뢰성 평가방법에 대한 연구도 진행될 것이다.

  • PDF

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.