• Title/Summary/Keyword: 헬륨-네온 laser

Search Result 25, Processing Time 0.026 seconds

Design of Precision Position Measuring System using Laser Interferometry (광간섭법을 이용한 정밀 위치측정 시스템 설계)

  • 김진상;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.145-149
    • /
    • 1997
  • A laser mesurement system, a modified Michelson interferometer,which can accurately measure high speed length and position of servomechanisms by detecting a phase shift in the measurement beam using an optical interference was developed. A frequency stabilized laser source and a 20 fold frequency interpolation and digitizing circuit were applied to the system. The refractive index of the ambient air was calibrated through the Edlen's formula. The system achieved a resolution of .lambda./40,16nm, a maximum allowable measurement speed of 600 mm/sec, and a length measurement range of 1500mm. Performance of the system was evaluated on the machining center in short and long length measurements

  • PDF

Design and Analysis of Displacement/Length Measuring System Using Laser Interferometry (광간섭법을 이용한 변위/길이 측정시스템의 설계 및 해석)

  • Kim, J.S.;Kim, S.C.;Chung, S.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.151-156
    • /
    • 1997
  • A laser measurement system, a modified Michelson interferometer, which can accurately measure high speed length and displacement of servomechanisms by detecting a phase shift in the measurement beam using an optical interference was developed. A frequency stabilized laser source and a 20 fold frequency interpolation and digitizing circuit were applied to the system. The refra- ctive index of the ambient air was calibrated through the Edlens formula. The system achieved a resolution of /40, 16nm, a maximum allow-able measurement speed of 600nm/sec, and a length measure- ment range of 1500 mm. Performance of the system was evaluated on the machining center in short and long length measurements.

  • PDF

A Study on On-line 5 Degrees of Freedom Error Measurement using Laser Optical System (레이져 광학장치를 이용한 온라인 5 자유도 오차측정에 관한연구)

  • 김진상;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.375-378
    • /
    • 1995
  • Although laser interferometer measurement system has the advantage of range and accuracy, the traditional error measurement methods for geometric errors(two straightness and three angular errors) of a machine tool measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric error of a moving body, an on-line measurement system for simultaneous detection of the five error components of a moving axis is required. An on-line measurement system with 5 degrees of freedom was developed for geometric error detection. Performance verification of the system was performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a side of machine tool.

  • PDF

Naloxone Reversal of He-Ne Laser Stimulation Induced Analgesia in Rat (헬륨 -네온 레이저자극으로 유발된 흰쥐 진통작용의 날록손 반전)

  • Lee Jae-Hyoung;Song In-Yong;Choi Eun-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.8 no.1
    • /
    • pp.15-20
    • /
    • 1996
  • The purpose of this study were to 1) determine the analgesic effect of 632.8 nm of helium-neon (He-Ne) laser stimulation on acupuncture point in rat and 2) determine the reversal of analgesic effect by naloxone injection. Eighteen Sprague-Dawley rats were devided into three groups : control (n=6) : laser (n=6), laser stimulation at $3.58\;J/cm^2$ ; and naloxone (n=6), 1 mg/kg of naloxone chloride inject into peritoneum before laser stimulation at $3.63J/cm^2$. Tail-flick latency were measured pretreat and posttreat with hot plate $(55^{\circ}C)$. Data were analyzed using one-way ANOVA and paired t-teat for tail-flick latency. No significant change was noted in the tail-flick latency in either control or naloxone groups. But significant increased in tail-flick latency in taller group. The results suggest that He-Ne laser induced analgesic effect, and endogenous opioids may be involved in He-Ne laser induced analgesia.

  • PDF

Offset Frequency Stabilization of He-Ne Lasers Using Phase Locked Loop (PLL을 이용한 헬륨-네온 레이저의 옵셋 주파수 안정화)

  • Yun Dong Hyun;Suh Ho Sung;Lyou Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.6
    • /
    • pp.496-501
    • /
    • 2005
  • This paper presents experimental results of the frequency offset locking of He-Ne lasers and the stability analysis. The master laser is free running, and the slave laser is a single-mode operating laser. The frequency difference of two lasers is stabilized to 200 MHz which can be synchronized using PLL servo. The measured beat frequency between two lasers was 200.004 MHz ${\pm}$ 0.15 MHz. The square root of Allan variance as a measure of stability in time domain is also measured. The long-term stability of the beat was worse than sort-term stability. With a gate time $\tau=1000\;s$, the square root of Allan variance was about 1 GHz. The results of the square root of Allan variance of the stabilized beat signal was a gate time of $\tau=1000\;s$, the square root of Allan variance was about 1.5 kHz. The long-term stability was improved by more than several hundred times compared with that without the stabilization.

Synthesis of an On-Line 5 Degrees of Freedom Error Measurement System for Translational Motion Rigid Bodies (병진운동 강체의 온라인 5자유도 운동오차 측정시스템 설계 및 해석)

  • 김진상;정성종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.93-99
    • /
    • 1998
  • Although laser interferometer measurement system has advantages of measurement range and accuracy, it has some disadvantages when measurement of multi degrees of freedom of motion are required. Because the traditional error measurement methods for geometric errors (two straightness and three angular errors) of a slide of machine tools measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric errors of a moving rigid body in real time processes, an on-line error measurement system for simultaneous detection of the five error components of a moving object is required. Using laser alignment technique and some optoelectronic components, an on-line measurement system with 5 degrees of freedom was developed for the geometric error detection in this study Performance verification of the system has been performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a slide of machine tools.

  • PDF

DESIGN OF THE RLG CURRENT STABILIZER CIRCUIT FOR ATTITUDE CONTROL IN THE SATELLITE (위성 자세제어용 RLG 전류 안정화 회로 설계)

  • Kim Eui-Chan;Choi Jae-Dong
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.2
    • /
    • pp.161-166
    • /
    • 2006
  • In this paper, we describe the RLG current stabilizer circuit for attitude control in the satellite. The RLG makes use of the Sagnac effect within a resonant of a HeNe laser. The difference between two discharge currents causes one of the gyro bias errors. The theoretical background and current stabilizer are introduced. It is verified that the circuit designed is applicable to the test of input voltage and temperature.

Effects of Intravenous He-Ne Laser Irradi on Meridian-Heart·Circulation CMP and Hyperlipidemia (정맥혈관내(靜脈血管內) 헬륨-네온 레이저 조사(照射)가 메리디안 심(心)·순환(循環) 대표점(代表點)과 고지혈증(高脂血症)에 미치는 영향(影響))

  • Ahn, Soo-gi;Lee, Sam-ro;Hwang, Woo-jun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.1
    • /
    • pp.269-284
    • /
    • 1998
  • The purpose of this study was to investigate the effect of ILIB(Intravenous Laser Irradiation of blood) on Meridian-Heart Circulation CMP and Hyperlipidemia. Circulatory symptom of 20 patients was treated with ILIB. After 10 times' treatment, changes of total cholesterol, HDL-cholesterol, triglyceride and Meridian-Heart Circulation CMP value were observed. The results were as follows : 1. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both pre-ID generation and post-ID generation. So, distinctive observation between pre-ID generation and post-ID generation became not relatively significant. 2. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both left and right. So, distinctive observation between left and right became not relatively significant. 3. In observation of Meridian-Heart CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 4. In observation of Meridian-Circulation CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 5. In concentration of plasma total cholesterol and plasma triglyceride, significant decrease was not observed in control group, but significant increase was observed in treatment group after treatment of Intravenous He-Ne laser Irradiation. 6. Significant concentration change of plasma HDL-cholesterol was not observed in both control group and treatment group. From above results, it was thought that Intravenous He-Ne Laser Irradiation was significant effect on heart circulatory system in human body.

  • PDF

Calibration and Performance Test of Electro-optical Distance Meters Using a Laser Interferometer (레이저 간섭계를 이용한 광파거리측정기의 교정과 특성분석)

  • Kim Jae Wan;Eom Tae Bong;Suh Ho Suhng
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.4
    • /
    • pp.367-374
    • /
    • 2004
  • In order for the measurement results of an electro-optical distance meter(EDM), which is widely used in surveying, to be reliable, an EDM should be calibrated. For the calibration of an EDM, we have settled a traceability chain, which connects the EDM under calibration to the definition of metre. The chain starts from the iodine stabilized He-Ne laser which realizes the definition of metre, and then connected to a stabilized laser interferometer, a standard EDM, and finally to the EDM under calibration through the baseline. We achieved the expanded calibration uncertainties of the scale and length measurement of an EDM being evaluated to be 6$\times$10$^{-6}$ and 0.2 mm, respectively. Two different calibration methods, and their results are compared.

Gyro HV Power Supply Design for Attitude Control in the Satellite (위성 자세제어용 자이로 HVPS 설계)

  • Kim, Eui-Chan;Koo, Ja-Chun
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.109-113
    • /
    • 2007
  • In this paper, the design process of the High Voltage Power Supply for RLG(Ring Laser Gyroscope) is described. The specification for High Voltage Power Supply(HVPS) is proposed. Also, The analysis of Flyback converter topology is explained. The Design for the HVPS is composed of the inverter circuit, feedback control circuit, high frequency switching transformer design, and voltage doubler circuit.

  • PDF