• Title/Summary/Keyword: 허용응력

Search Result 408, Processing Time 0.026 seconds

Reliability Analysis of Final Settlement Using Terzaghi's Consolidation Theory (테르자기 압밀이론을 이용한 최종압밀침하량에 관한 신뢰성 해석)

  • Chae, Jong Gil;Jung, Min Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6C
    • /
    • pp.349-358
    • /
    • 2008
  • In performing the reliability analysis for predicting the settlement with time of alluvial clay layer at Kobe airport, the uncertainties of geotechnical properties were examined based on the stochastic and probabilistic theory. By using Terzaghi's consolidation theory as the objective function, the failure probability was normalized based on AFOSM method. As the result of reliability analysis, the occurrence probabilities for the cases of the target settlement of ${\pm}10%,\;{\pm}25%$ of the total settlement from the deterministic analysis were 30~50%, 60%~90%, respectively. Considering that the variation coefficients of input variable are almost similar as those of past researches, the acceptable error range of the total settlement would be expected in the range of 10% of the predicted total settlement. As the result of sensitivity analysis, the factors which affect significantly on the settlement analysis were the uncertainties of the compression coefficient Cc, the pre-consolidation stress Pc, and the prediction model employed. Accordingly, it is very important for the reliable prediction with high reliability to obtain reliable soil properties such as Cc and Pc by performing laboratory tests in which the in-situ stress and strain conditions are properly simulated.

Seismic Performance-Based Design for Breakwater (방파제의 성능기반 내진설계법)

  • Kim, Young-Jun;Park, Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.91-101
    • /
    • 2022
  • The 1995 Kobe earthquake caused a massive damage to the Port of Kobe. Therefore, it was pointed out that it was impossible to design port structures for Level II (Mw 6.5) earthquakes with quasi-static analysis and Allowable Stress Design methods. In Japan and the United States, where earthquakes are frequent, the most advanced design standards for port facilities are introduced and applied, and the existing seismic design standards have been converted to performance-based design. Since 1999, the Korean Port Seismic Design Act has established a definition of necessary facilities and seismic grades through research on facilities that require seismic design and their seismic grades. It has also established a performance-based seismic design method based on experimental verification. In the performance-based seismic design method of the breakwater proposed in this study, the acceleration time history on the surface of the original ground was subjected to a fast Fourier transform, followed by a filter processing that corrected the frequency characteristics corresponding to the maximum allowable displacement with respect to performance level of the breakwater and the filtered spectrum. The horizontal seismic coefficient for the equivalent static analysis considering the displacement was calculated by inversely transforming (i.e., subjected to an inverse fast Fourier transform) into the acceleration time history and obtaining the maximum acceleration value. In addition, experiments and numerical analysis were performed to verify the performance-based seismic design method of breakwaters suitable for domestic earthquake levels.

Fault reactivation potential during $CO_2$ injection in the Gippsland Basin, Australia (호주 Gippsland Basin에서 $CO_2$ 주입 중 단층 재활성화의 가능성)

  • Ruth, Peter J. van;Nelson, Emma J.;Hillis, Richard R.
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.50-59
    • /
    • 2006
  • The risk of fault reactivation in the Gippsland Basin was calculated using the FAST (Fault Analysis Seal Technology) technique, which determines fault reactivation risk by estimating the increase in pore pressure required to cause reactivation within the present-day stress field. The stress regime in the Gippsland Basin is on the boundary between strike-slip and reverse faulting: maximum horizontal stress $({\sim}\;40.5\;Mpa/km)$ > vertical stress (21 Mpa/km) ${\sim}$ minimum horizontal stress (20 MPa/km). Pore pressure is hydrostatic above the Campanian Volcanics of the Golden Beach Subgroup. The NW-SE maximum horizontal stress orientation $(139^{\circ}N)$ determined herein is broadly consistent with previous estimates, and verifies a NW-SE maximum horizontal stress orientation in the Gippsland Basin. Fault reactivation risk in the Gippsland Basin was calculated using two fault strength scenarios; cohesionless faults $(C=0;{\mu}=0.65)$ and healed faults $(C=5.4;\;{\mu}=0.78)$. The orientations of faults with relatively high and relatively low reactivation potential are almost identical for healed and cohesionless fault strength scenarios. High-angle faults striking NE-SW are unlikely to reactivate in the current stress regime. High-angle faults oriented SSE-NNW and ENE-WSW have the highest fault reactivation risk. Additionally, low-angle faults (thrust faults) striking NE-SW have a relatively high risk of reactivation. The highest reactivation risk for optimally oriented faults corresponds to an estimated pore pressure increase (Delta-P) of 3.8 MPa $({\sim}548\;psi)$ for cohesionless faults and 15.6 MPa $({\sim}2262\;psi)$ for healed faults. The absolute values of pore pressure increase obtained from fault reactivation analysis presented in this paper are subject to large errors because of uncertainties in the geomechanical model (in situ stress and rock strength data). In particular, the maximum horizontal stress magnitude and fault strength data are poorly constrained. Therefore, fault reactivation analysis cannot be used to directly measure the maximum allowable pore pressure increase within a reservoir. We argue that fault reactivation analysis of this type can only be used for assessing the relative risk of fault reactivation and not to determine the maximum allowable pore pressure increase a fault can withstand prior to reactivation.

The structural analysis and design methods considering joint bursting in the segment lining (조인트 버스팅을 고려한 세그먼트 라이닝 구조해석 및 설계방법)

  • Kim, Hong-Moon;Kim, Hyun-Su;Jung, Hyuk-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1125-1146
    • /
    • 2018
  • Segment lining applied to the TBM tunnel is mainly made of concrete, and it requires sufficient structural capacity to resist loads received during the construction and also after the completion. When segment lining is design to the Limit State Design, both Ultimate Limit State (ULS) and Service Limit State (SLS) should be met for the possible load cases that covers both permanent and temporary load cases - such as load applied by TBM. When design segment lining, it is important to check structural capacity at the joints as both temporary and permanent loads are always transferred through the segment joints, and sometimes the load applied to the joint is high enough to damage the segment - so called bursting failure. According to the various design guides from UK (PAS 8810, 2016), compression stress at the joint surface can generate bursting failure of the segment. This is normally from the TBM's jacking force applied at the circumferential joint, and the lining's hoop thrust generated from the permanent loads applied at the radial joint. Therefore, precast concrete segment lining's joints shall be designed to have sufficient structural capacity to resist bursting stresses generated by the TBM's jacking force and by the hoop thrust. In this study, bursting stress at the segment joints are calculated, and the joint's structural capacity was assessed using Leonhardt (1964) and FEM analysis for three different design cases. For those three analysis cases, hoop thrust at the radial joint was calculated with the application of the most widely used limit state design codes Eurocode and AASHTO LRFD (2017). For the circumferential joints bursting design, an assumed TBM jack force was used with considering of the construction tolerance of the segments and the eccentricity of the jack's position. The analysis results show reinforcement is needed as joint bursting stresses exceeds the allowable tensile strength of concrete. This highlights that joint bursting check shall be considered as a mandatory design item in the limit state design of the segment lining.

Overview and Analysis of New International Code of Practice for Pile Foundation

  • Yoon, Gil-Lim
    • Geotechnical Engineering
    • /
    • v.12 no.3
    • /
    • pp.73-82
    • /
    • 1996
  • Limit state design(LSD) principles employing load and resistance factor design(LRFD) are coming into use in geotechnical engineering community around the world. Current working (allowable) stress design principles are expected to be replaced by LRFH method in the near future. North America has recently adopted LRFD principles, and European community has also developed its own code called "Eurocode" based on partial safety factor design which is essentially the same as LRFD. Relevant review and analysis of new global design codes are prerequisites to adopting these codes in the Korean construction industry and in the Korean foundation design prac titre. This paper reviews geotechnical aspects of LRFD and Eurocode, and analyzes the geomaterial resistance factors in LRFD for the design of axially-loaded driven piles.

  • PDF

Optimized Structure Design of Composite Cyclocopter Rotor System using RSM (반응면 기법을 이용한 복합재료 사이클로콥터 로터의 최적 구조 설계)

  • Hwang In Seong;Hwang Chang Sup;Kim Min Ki;Kim Seung Jo
    • Composites Research
    • /
    • v.18 no.4
    • /
    • pp.52-58
    • /
    • 2005
  • A cyclocopter propelled by the cycloidal blade system, which can be described as a horizontal rotary wing, is a new concept of VTOL vehicle. In this paper, optimized structure design is carried out for the aerodynamically optimized cyclocopter rotor system. Database is obtained fer design variables such as stacking sequence (ply angles), number of plies and spar locations through MSC/NASTRAN and optimum values are determined by RSM and some other optimizing processes. For the rotor system including optimized blade and composite hub m, the maximum stress by static analysis is within the failure criteria. And the rotor system is designed for the purpose of avoiding possible dynamic instabilities by inconsistency between frequencies of rotor rotation and some low natural frequencies of rotor.

A Study on Design Criteria of Piping System in Petrochemical Plant (석유화학 플랜트의 배관계 설계기준에 대한 연구)

  • Min, Sun-Kuo;Choi, Myung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.192-199
    • /
    • 2002
  • Largely, there are three kinds of the design criteria of piping system in petrochemical plant. The first is on the pipe thickness in accordance with the design pressure of piping system. The second is on the static state evaluation by thermal growth and the other is on the dynamic evaluation by piping vibration. According to the ASME B31.3 code, the internal pressure design thickness fur straight pipe shall be calculated as a code formula. And the static design by thermal displacement is defined 7000 cycles of fatigue life in operating the piping system with a design condition. However, the dynamic design evaluation in comparative with small displacements of high frequencies to the static condition has not established clearly the method, yet. So, this study purposes to present the trial of a proposal of dynamic design criterion on the basis of static design method.

Safety Evaluation Development of Urban Structures Using Removal Bridge (철거 교량을 활용한 도시시설물의 안전성 평가 기법 개발)

  • Lee, Won Woo;Kim, Jung Hoon;Kang, Chang Mook;Kong, Jung Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.81-81
    • /
    • 2011
  • 현재 국내에서 사용하고 있는 교량구조물의 성능평가방법으로는 크게 공용하중에 대한 내하율을 구하기 위하여 허용응력개념이나 강도설계 개념을 적용한 내하력 평가 기법이 사용되고 있다. 그러나 위의 방법들은 일반적으로 공용연수의 경과에 따른 재료 및 구조적 성능의 손실과 여러 가지 하중 및 환경적 요인들의 불확실성으로 인하여 발생하는 손상 및 열화를 반영하기 어렵다. 그리고 제원 및 재료물성치의 불확실성에 대한 기존 설계 자료의 DB 부족으로 기존의 평가방법에서는 이러한 시간의 경과에 따른 성능저하를 정확히 산정할 수 없어 이론상의 값과 실제 구조물과의 차이로 인한 불확실성이 존재 한다. 이에 본 연구에서는 공용년수 경과에 따른 시설물의 재료 구조적인 성능 및 거동분석 수행, 신뢰성 해석 수행을 바탕으로 교량 안전성 평가의 합리성 및 현실성을 제고하며, 구조 신뢰성 해석을 수행함으로써 실제 구조물의 강도 한계상태에 대한 파괴확률을 산정하고 그에 대응하는 위험도를 평가함으로써 안전성 검토를 수행하였다. 본 실험을 통해 1. 재료 강도, 부재 제원, 긴장력, 작용하중 등에 있어 설계 시 가정과 실제 사용 환경 사이의 변동성이 존재한다는 것을 알 수 있었으며, 2. 연구 수행 결과 일반 정밀진단 및 해석에서는 얻을 수 없는 다양하고 중요한 결과를 산출할 수 있었으며 이러한 연구 결과를 바탕으로 개선된 성능평가 기법이 제안 될 수 있음을 알 수 있었다.

  • PDF

A study on the static seimic loads for the space structures of beam string structure (장현보구조형식을 가지는 공간구조물의 정적지진하중 평가법에 관한 연구)

  • Kim, Kwang-Il;Jung, Chan-Woo;Kang, Joo-Won
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.127-132
    • /
    • 2008
  • Recent years, the response characteristics of large space structures have been studied. Then, for the large space structures with large rise-span ratio, it is clarified that the anti-symmetric mode are representatively amplified. That means the static seismic load for general ramen structure is not suitable for the space structure. In this paper, we propose static seismic loads for space structures and its concept. And for the space structures of beam string structures, execute the time history analysis and quasi static analysis and compare the results of them. From the results, we can prove the validity of static seismic load for space structure.

  • PDF

Design and Structure Analysis of a Tower Service Lift for Offshore Wind Power System (해상풍력발전시스템 타워서비스리프트 설계 및 구조해석)

  • Choi, Young-Do;Son, Sung-Woo;Jang, Ho-Choul;Choi, Nak-Joon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.101-108
    • /
    • 2012
  • The purpose of this study is to establish a design method of tower service lift for offshore wind power system, as well as to conduct structure analysis of the service lift system. The service lift system will be built in the internal area of tower of the offshore wind power system. Design and structure analysis for the tower service lift system are conducted to clarify the stability and reliability of the system. Main objective of the design is to secure sufficient capability of transportation of workers and equipment with satisfactory performance within the designed tolerance limit. Total deformation and equivalent stress of the lift system by external load are examined using the results of structure analysis.