• Title/Summary/Keyword: 해수냉각시스템

Search Result 33, Processing Time 0.032 seconds

Performance analysis of a cooling system with refrigerant in a marine absorption refrigerator (선박용 흡수식 냉동기의 냉매적용 냉각 시스템 성능 분석)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.282-287
    • /
    • 2016
  • Recently in order to protect the ocean environment and to reduce energy consumption, shipbuilders have been developing highly economized ships. This research analyzed the possibility of adopting the onshore absorption refrigerator to offshore ships having a cooling system with refrigerant by using the waiste heat of the engine jacket cooling water instead of compression refrigerators. The results showed that R236fa could be a suitable medium for absorbing the heat of the absorber and condenser in an absorption refrigerator. The cooling system using R236fa achieved a high COP of 0.798, which is 15% and 5% higher than an air cooling system with a cooling tower and a water cooling system with a heat exchanger, respectively. The cooling system with R236fa achieved high efficiency with a 25% reduction in flow rate of LiBr solution and only 15.7% flow rate of cooling medium as compared to the water cooling system. The heating of sea water by the engine jacket water flowing out from the generator can prevent the crystallization of LiBr solution due to the low temperature of sea water.

A Feasibility Study of Seawater Injection Nozzle Prototype Development by Using 3D Printing (3D 프린팅을 이용한 해수분사용 노즐 시제품 개발의 가능성 연구)

  • Yoon, Seok-Tea;Park, Jong-Chun;Cho, Yong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.51-57
    • /
    • 2021
  • The seawater cooling system of naval ships is installed to remove the toxic substances generated by CBR (Chemical, Biological, and Radiological) warfare and reduce the infrared signature of naval ships from outside the hull. The dispersion range of the nozzle is determined according to the injection pressure of seawater and the nozzle type. Therefore, it is necessary to select the appropriate injection pressure and design the optimal nozzles to increase the seawater dispersion area and maximize the efficiency of the cooling system. In this study, the applying feasibility of 3D printing technology to produce an injection nozzle for the seawater cooling system was examined. To this end, the extruded plastic specimens were fabricated by 3D printing, and the physical properties of the specimens were estimated through tensile testing. After this, the strain and stress of the nozzle as a function of the pressure were simulated by applying the estimated results to the finite element analysis. The finite element analysis results showed that the nozzle remained within the elastic range at the optimal pressure. The nozzle was estimated to be structurally stable, and the possibility of this study was confirmed.

The Design of Small but Large Capacity Ocean Current Turbine Generator for High Speed Ocean Current (고속 해류용 소형 대용량 해류발전기의 설계)

  • Jang, Kyungsoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.160.2-160.2
    • /
    • 2011
  • 바다를 가로막는 방벽이나 방조제의 배수갑문 또는 조력발전소의 수문과 같이 인공 해양구조물을 통하여 흐르는 고속 해류를 이용하여 발전하는 해류발전 방식에 있어서, 고속 해류에 적합한 수차터빈과 발전기의 특성을 알아보았다. 조석간만의 차가 큰 지역에 설치되는 인공 해양구조물을 지나는 해류는 인공 해양구조물 전후에 발생하는 해수의 위치에너지 차이가 운동에너지로 바뀌면서 조석간만의 자연현상에 의해 발생되는 조류의 속도보다 훨씬 더 빠르게 흐른다. 이론적으로 우리나라의 서해안의 조석간만의 범위 3~8m로부터 7.5~12m/s 정도의 고속 해류가 가능하다. 이러한 경우에 적합한 해류발전기는 수차터빈 날개지름의 크기가 5m에서부터 12m 이하이면서, 증속기어박스와 발전기, 유압시스템 및 냉각시스템 그리고 전력변환장치를 포함하는 발전시설들을 해수면 위에 설치하는 것이 바람직하다.

  • PDF

A Study on the Refrigerant Characteristics of the Organic Rankine Cycle Power System Using the Waste Heat of the Main Propulsion Engine (선박 주 추진 엔진폐열을 이용하는 고온도차발전시스템의 냉매특성에 관한 연구)

  • Song, Young-uk;Jee, Jae-hoon;Park, Sang-kyun;Oh, Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.839-845
    • /
    • 2021
  • In this study, it shows the efficiency of each refrigerant through simulation method for ORC (Organic Rankine Cycle) power generation that converts waste heat discarded by ship exhaust into electricity for the purpose of reducing CO2 emission and increasing ship waste heat recovery. by Simulation was performed with waste heat from the exhaust gas which is relatively high temperature and cooling sea water which is relatively low temperature from ships. As a result of the sea water cooling ORC power generating system, efficiency of the working fluid with R717 is highest as a 2.86 % and the next working fluid is R152a, R134a, R143a and R125a.

Development of a PCS Simulator and Data Storage System for Energy Saving in the Ship (선박 에너지 절감을 위한 PCS 시뮬레이터 및 데이터 저장 시스템 개발)

  • Oh, Jin-Seok;Kang, Young-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2189-2196
    • /
    • 2015
  • According to increase environmental pollutions and fuel costs, The study of energy saving in the ship is proceeding actively. PCS is pump control system for cooling system in the ship to improve the energy efficiency by controling rotation speed of sea water pump, fresh water pump and position of 3way valve. In this paper, we develop the PCS simulator that has an environment similar to the cooling system of the actual vessel to ensure reliability of the PCS. Also, PC-based control and data storage system for PCS simulator is developed. To develop this system, National Instrument's cDAQ and LabVIEW are used. Finally, confirm the behavior of the simulator by analyzing the saving data.

Development of Small Package Sea Water Chiller for Live Fish Hold (소형 패키지 활어조 냉각시스템 개발)

  • 한인근;백승문;문춘근;김재돌;윤정인
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2000.10a
    • /
    • pp.58-59
    • /
    • 2000
  • 최근들어 연근해 어장의 황폐화로 일시 다획성 어종의 어획량이 줄어들고 있을 뿐만 아니라, 배타적 경제수역 선포로 연근해 어장의 상실에 따른 어획량의 감소가 예상되고 있다. 현행의 해수와 육상빙을 50:50으로 하여 어획물을 저장 운반하는 방법인 수빙식은 선도 유지가 잘되지 않으므로 단백질 자원의 고도이용 및 국민건강 증진을 위해서는 어획된 생선을 운반시에 운반선에 적절한 선도관리 장치를 설치하여 선도저하를 억제시켜야 한다. (중략)

  • PDF

Performance Test for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy (해수열원 및 폐열이용 고성능 열펌프 시스템 성능실험)

  • 최광일;오종택;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.979-986
    • /
    • 2003
  • The performance characteristics of heating and cooling operation for a heat pump system using seawater heat source and exhaust energy are presented. The heat pump system is made of a waste heat recovery system and a vapor compression refrigeration system. The working fluid is R-22. The heat pump system COPs are measured during heating and cooling operation modes, and the resultant COPs were 9.7 and 7.9, respectively, which are three times higher than those of the heat pump itself. Therefore, the performance of the heat pump system using exhaust energy is excellent compared to that of a general heat pump. The experimental data can be effectively used for the design of the high efficient heat pump using a seawater heat source.

Cavitation Analysis on Ship Seawater Pump Using CFD (CFD를 이용한 선박용 해수펌프의 공동현상에 대한 분석)

  • Kim, Bu-Gi;Kim, Hong-Ryeol;Yang, Chang-Jo;Kim, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.4
    • /
    • pp.400-406
    • /
    • 2017
  • The model used in this study was reversed to analyze the cause of excessive damage that occurred inside the rotating system and pipe system of a centrifugal-type seawater pump on a ship. For this purpose, internal flow analysis on a cooling seawater pump was performed using CFD. As a result, the shape and boundary conditions of the target pump were set by reverse engineering, and pump efficiency at a design operating point of $125m^3/h$ was calculated as 85.3 % with a head of 32.0 m. The maximum efficiency point of the target pump was estimated to be 86.2 % at $150m^3/h$, but this differed from the actual operating point. At $112.5m^3/h$, which was the lowest flow point, flow was unstable due to the characteristics of the low flow point and analysis convergence was not good. The purpose of this study was to clarify the cause of ongoing cavitation in seawater pumps and piping systems in operation. Future research will be needed to clarify causes for pipe systems in the future by performing calculations for the total piping system of an inlet and outlet, in addition to measuring the flow rate of each branch pipe.

Study on the Electric Energy Saving System in Marine Cooling System (선박 냉각시스템에서의 전기 에너지 절감 시스템에 관한 연구)

  • Kim, Yun-Hyung;Bae, Soo-Young;Jung, Sung-Young;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1157-1163
    • /
    • 2008
  • Fuel represents a significant portion of the operating costs of voyages of the vessel. Under this situation, dramatic increase in fuel price caused a problem that earnings of ship becomes decreased seriously. Pumps in a cooling system of the vessel are often operated inefficiently. The reasons will vary from process to process and application to application. Inefficiency of pumps is one of the reason for making the cost of operating the vessel increased. This paper suggests energy-effective cooling system that controls sea water pumps with inverters to reduce energy consumption in vessel by conducting simulation with LabVIEW. Results shows that electric energy consumption of pumps are significantly deceased. If this energy-effective cooling system is applied to other systems which need cooling, it could be useful in reducing electric energy wastage.

A Study on the Energy Saving System with the LabVIEW (LabVIEW를 이용한 에너지 절감시스템에 관한 연구)

  • Oh, Jin-Seok;Jo, Kwan-Jun;Kwak, Jun-Ho;Jin, Sun-Ho;Kim, Jong-Do;Lee, Hong-chan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.250-251
    • /
    • 2005
  • The ESS(Energy Saving System) is composed of economic control algorithm for main sea water cooling pump with inverter. The control system of ESS is designed with the Field-Point and LabVIEW. This paper presents the control process and results of control and monitor for ESS.

  • PDF