• Title/Summary/Keyword: 해상의료

Search Result 125, Processing Time 0.028 seconds

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

Development of a Korean Adult Female Voxel Phantom, VKH-Woman, Based on Serially Sectioned Color Slice Images (고해상도 연속절단면 컬러해부영상을 이용한 한국인 성인여성 복셀팬텀 VKH-Woman 개발)

  • Jeong, Jong Hwi;Yeom, Yoen Soo;Han, Min Cheol;Kim, Chan Hyeong;Ham, Bo Kyoung;Hwang, Sung Bae;Kim, Seong Hoon;Lee, Dong-Myung
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.199-208
    • /
    • 2012
  • The computational human phantom including major radiation sensitive organs at risk (OARs) can be used in the field of radiotherapy, such as the variation of secondary cancer risks caused by the radiation therapy and the effective dose evaluation in diagnostic radiology. The present study developed a Korean adult female voxel phantom, VKH-Woman, based on serially sectioned color slice images of Korean female cadaver. The height and weight of the developed female voxel phantom are 160 cm and 52.72 kg, respectively that are virtually close to those of reference Korean female (161 cm and 54 kg). The female phantom consists of a total of 39 organs, including 27 organs recommended in the ICRP 103 publication for the effective dose calculations. The female phantom composes of $261{\times}109{\times}825$ voxels (=23,470,425 voxels) and the voxel resolution is $1.976{\times}1.976{\times}2.0619mm^3$ in the x, y, and z directions. The VHK-Woman is provided as both ASCII and Binary data formats to be conveniently implemented in Monte Carlo codes.

Endoscopic Bio-Imaging Using Optical Coherence Tomography (마이크로 내시경 및 첨단 광 단층촬영기법을 이용한 생체 이미징)

  • Ahn, Yeh-Chan;Brenner, Matthew;Chen, Zhongping
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.466-471
    • /
    • 2011
  • Optical coherence tomography(OCT) is an emerging medical diagnostic tool that draws great attention in medical and biological fields. It has a 10-100 times higher spatial resolution than that of the clinical ultrasound but lower imaging depth such as 1-2 mm. In order to image internal organs, OCT needs an endoscopic probe. In this paper, the principle of Fourier-domain optical coherence tomography with high-speed imaging capability was introduced. An OCT endoscope based on MEMS technology was developed. It was attached to the Fourier-domain OCT system to acquire three-dimensional tomographic images of gastrointestinal tract of New Zealand white rabbit. The endoscope had a two-axis scanning mirror that was driven by electrostatic force. The mirror stirred an incident light to sweep two-dimensional plane by scanning. The outer diameter of the endoscope was 6 mm and the mirror diameter was 1.2 mm. A three-dimensional image rendered by 200 two-dimensional tomographs with $200{\times}500$ pixels was displayed within 3.5 seconds. The spatial resolution of the OCT system was 8 ${\mu}m$ in air.

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

A Study and Design of Beam Scanning Array Antenna using IR-UWB (IR-UWB를 이용한 빔 스캐닝 배열 안테나 설계 및 연구)

  • Kim, Keun-Yong;Kang, Eun-Kyun;Kim, Jin-Woo;Ra, Keuk-Whan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.194-201
    • /
    • 2014
  • This paper is able to be solved by improving degradation in multi-path environment by adjust beam pattern angle through modifying pulse phase of each antennas by using TRM (Transmitter Receiver Module). Beam Scanning Array Antenna, which is transmitter/receiver that improves degradation in multi-path environment without any signal distortion, is designed and manufactured. Beam Scanning Array Antenna should be able to send/receive signal at the antenna's longitudinal part without distortion and should not influences other systems. Also, it should include target detecting ability by beam steering.Dispersion characteristic of Beam Scanning Antenna, which is designed, is analysed by using fidelity, and steering and radar resolution performance is verified by using $1cm{\times}1cm$ sized target. To manufacture Beam Scanning Array Antenna, control board and GUI, which is able to control Vivaldi Antenna for IR-UWB, Tri-Band Wilkinson power divider, and TRM (Transmitter Receiver Module), is designed. Throughout this research, developed Beam Scanning UWB Array Antenna system is adoptable for radar application field. and time domain analysis techniques by using network analyser made the antenna characteristics analysis for setting up antenna more accurate. In addition, it makes beam width checking without difficulties.

Generation of High-Resolution Chest X-rays using Multi-scale Conditional Generative Adversarial Network with Attention (주목 메커니즘 기반의 멀티 스케일 조건부 적대적 생성 신경망을 활용한 고해상도 흉부 X선 영상 생성 기법)

  • Ann, Kyeongjin;Jang, Yeonggul;Ha, Seongmin;Jeon, Byunghwan;Hong, Youngtaek;Shim, Hackjoon;Chang, Hyuk-Jae
    • Journal of Broadcast Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • In the medical field, numerical imbalance of data due to differences in disease prevalence is a common problem. It reduces the performance of a artificial intelligence network, leading to difficulties in learning a network with good performance. Recently, generative adversarial network (GAN) technology has been introduced as a way to address this problem, and its ability has been demonstrated by successful applications in various fields. However, it is still difficult to achieve good results in solving problems with performance degraded by numerical imbalances because the image resolution of the previous studies is not yet good enough and the structure in the image is modeled locally. In this paper, we propose a multi-scale conditional generative adversarial network based on attention mechanism, which can produce high resolution images to solve the numerical imbalance problem of chest X-ray image data. The network was able to produce images for various diseases by controlling condition variables with only one network. It's efficient and effective in that the network don't need to be learned independently for all disease classes and solves the problem of long distance dependency in image generation with self-attention mechanism.

Evaluation of Image Quality for Compressed SENSE(CS) Method in Cerebrovascular MRI: Comparison with SENSE Method (뇌혈관자기공영영상에서 Compressed SENSE(CS) 기법에 대한 영상의 질 평가: SENSE 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.999-1005
    • /
    • 2021
  • The object of this research is CS, which increases resolution while shortening inspection time, is applied to MRA to compare the quality of images for SENSE and CS techniques and to evaluate SNR and CNR to find out the optimal techniques and to provide them as clinical basic data based on this information. Data were analyzed on 32 patients who performed TOF MRA tests at a university hospital in Chung cheong-do (15 males, 17 females), ICA stenosis:10, M1 Aneurysm:10, and average age 53 ± 4.15). In the inspection, the inspection equipment was Ingenia CX 3.0T, Archieva 3.0T, and 32 channel head coil and 3D gradient echo as a method for equipment data. SNR and CNR of each image were measured by quantitative analysis, and the quality of the image was evaluated by dividing the observer's observation into 5 grades for qualitative evaluation. Imaging evaluation is described as being significant when the p-value is 0.05 or less when the paired T-test and Wilcoxon test are performed. Quantitative analysis of SNR and CNR in TOF MRA images Compared to the SENSE method, the CS method is a method measurement method (p <0.05). As an observer's evaluation, the sharpness of blood vessels: CS (4.45 ± 0.41), overall image quality: CS (4.77 ± 0.18), background suppression of images: CS (4.57 ± 0.18) all resulted in high CS technique (p = 0.000). In conclusion, the Compressed SENSE TOF MRA technique shows superior results when comparing and evaluating the SENSE and Compressed SENSE techniques in increased flow rate magnetic resonance angiography. The results are thought to be the clinical basis material in the 3D TOF MRA examination for brain disease.

Modified Pyramid Scene Parsing Network with Deep Learning based Multi Scale Attention (딥러닝 기반의 Multi Scale Attention을 적용한 개선된 Pyramid Scene Parsing Network)

  • Kim, Jun-Hyeok;Lee, Sang-Hun;Han, Hyun-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.45-51
    • /
    • 2021
  • With the development of deep learning, semantic segmentation methods are being studied in various fields. There is a problem that segmenation accuracy drops in fields that require accuracy such as medical image analysis. In this paper, we improved PSPNet, which is a deep learning based segmentation method to minimized the loss of features during semantic segmentation. Conventional deep learning based segmentation methods result in lower resolution and loss of object features during feature extraction and compression. Due to these losses, the edge and the internal information of the object are lost, and there is a problem that the accuracy at the time of object segmentation is lowered. To solve these problems, we improved PSPNet, which is a semantic segmentation model. The multi-scale attention proposed to the conventional PSPNet was added to prevent feature loss of objects. The feature purification process was performed by applying the attention method to the conventional PPM module. By suppressing unnecessary feature information, eadg and texture information was improved. The proposed method trained on the Cityscapes dataset and use the segmentation index MIoU for quantitative evaluation. As a result of the experiment, the segmentation accuracy was improved by about 1.5% compared to the conventional PSPNet.

A low noise, wideband signal receiver for photoacoustic microscopy (광음향 현미경 영상을 위한 저잡음 광대역 수신 시스템)

  • Han, Wonkook;Moon, Ju-Young;Park, Sunghun;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.507-517
    • /
    • 2022
  • The PhotoAcoustic Microscopy (PAM) has been proved to be a useful tool for biological and medical applications due to its high spatial and contrast resolution. PAM is based on transmission of laser pulses and reception of PA signals. Since the strength of PA signals is generally low, not only are high-performance optical and acoustic modules required, but high-performance electronics for imaging are also particularly needed for high-quality PAM imaging. Most PAM systems are implemented with a combination of several pieces of equipment commercially available to receive, amplify, enhance, and digitize PA signals. To this end, PAM systems are inevitably bulky and not optimal because general purpose equipment is used. This paper reports a PA signal receiving system recently developed to attain the capability of improved Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of PAM images; the main module of this system is a low noise, wideband signal receiver that consists of two low-noise amplifiers, two variable gain amplifiers, analog filters, an Analog to Digital Converter (ADC), and control logic. From phantom imaging experiments, it was found that the developed system can improve SNR by 6.7 dB and CNR by 3 dB, compared to a combination of several pieces of commercially available equipment.

Optimization of MRI Protocol for the Musculoskeletal System (근골격계 자기공명영상 프로토콜의 최적화)

  • Hong Seon Lee;Young Han Lee;Inha Jung;Ok Kyu Song;Sungjun Kim;Ho-Taek Song;Jin-Suck Suh
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.21-40
    • /
    • 2020
  • Magnetic resonance imaging (MRI) is an essential modality for the diagnosis of musculoskeletal system defects because of its higher soft-tissue contrast and spatial resolution. With the recent development of MRI-related technology, faster imaging and various image plane reconstructions are possible, enabling better assessment of three-dimensional musculoskeletal anatomy and lesions. Furthermore, the image quality, diagnostic accuracy, and acquisition time depend on the MRI protocol used. Moreover, the protocol affects the efficiency of the MRI scanner. Therefore, it is important for a radiologist to optimize the MRI protocol. In this review, we will provide guidance on patient positioning; selection of the radiofrequency coil, pulse sequences, and imaging planes; and control of MRI parameters to help optimize the MRI protocol for the six major joints of the musculoskeletal system.