Abstract
The computational human phantom including major radiation sensitive organs at risk (OARs) can be used in the field of radiotherapy, such as the variation of secondary cancer risks caused by the radiation therapy and the effective dose evaluation in diagnostic radiology. The present study developed a Korean adult female voxel phantom, VKH-Woman, based on serially sectioned color slice images of Korean female cadaver. The height and weight of the developed female voxel phantom are 160 cm and 52.72 kg, respectively that are virtually close to those of reference Korean female (161 cm and 54 kg). The female phantom consists of a total of 39 organs, including 27 organs recommended in the ICRP 103 publication for the effective dose calculations. The female phantom composes of $261{\times}109{\times}825$ voxels (=23,470,425 voxels) and the voxel resolution is $1.976{\times}1.976{\times}2.0619mm^3$ in the x, y, and z directions. The VHK-Woman is provided as both ASCII and Binary data formats to be conveniently implemented in Monte Carlo codes.
Keywords
Korean adult female voxel phantom; Serially sectioned color slice images; Monte Carlo;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Jiang H, Wang B, Xu XG, Suit HD, Paganetti H: Simulation of organ-specific patient effective dose due to secondary neutrons in proton radiation treatment. Phys Med Biol 50:4337-4354 (2005)   DOI   ScienceOn
2 Ding A, Mille MM, Liu T, Caracappa PF, Xu XG: Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose. Phys Med Biol 57:2441-2459 (2012)   DOI   ScienceOn
3 Park S, Lee JK, Lee C: Development of a Korean adult male computational phantom for internal dosimetry calculation. Radiat Prot Dosim 121:257-264 (2006)   DOI   ScienceOn
4 Lee C, Lee C, Park SH, Lee JK: Development of the two Korean adult tomographic computational phantoms for organ dosimetry. Med Phys 33:380-390 (2006)   DOI   ScienceOn
5 Park SH, Lee JK, Lee C: Dose conversion coefficients calculated using tomographic phantom, KTMAN-2, for X-ray examination of cardiac catheterisation. Radiat Prot Dosim 118:275-279 (2008)
6 Kim CH, Choi SH, Jeong JH, Lee C, Chung MS: HDRK-Man: a whole-body voxel model based on high-resolution color slice images of a Korean adult male cadaver. Phys Med Biol 53:4093-4106 (2008)   DOI   ScienceOn
7 Kim CH, Jeong JH, Bolch WE, Cho KW, Hwang SB: A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation. Phys Med Biol 56:3137-3161 (2011)   DOI   ScienceOn
8 ICRP Publication 103: The 2007 recommendations of the international commission on radiological protection. International Commission on Radiological Protection, ELSEVIER Press, Oxford (2008)
9 Park S, Lee JK, Kim JI, et al: In vivo organ mass of Korean adults obtained from whole-body magnetic resonance data. Radiat Prot Dosim 118:275-279 (2006)   DOI
10 Schlattl H, Zankl M, Petoussi-Henss N: Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures. Phys Med Biol 52:2123-2145 (2007)   DOI   ScienceOn
11 ICRP Publication 89: Basic anatomical and physiological data for use in radiological protection: Reference values. International Commission on Radiological Protection, Pergamon Press, Oxford (2002)
12 ICRP Publication 60: 1990 recommendations of the international Commission on radiological protection. International Commission on Radiological Protection, Pergamon Press, Oxford (1990)
13 Ferrari P, Gualdrini G: An improved MCNP version of the NORMAN voxel phantom for dosimetry studies. Phys Med Biol 50:4299-4316 (2005)   DOI   ScienceOn