• Title/Summary/Keyword: 한랭지

Search Result 27, Processing Time 0.031 seconds

A Study on Current Extent of Damage of Road Tunnel Lining in Cold Regions (Gangwon-do) (한랭지역(강원권)에서의 도로터널 라이닝부 피해 현황 연구)

  • Jin, Hyunwoo;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.1
    • /
    • pp.49-58
    • /
    • 2017
  • Due to low annual average temperature, road tunnel lining in domestic cold region (Gangwon province) experiences durability problems. The financial and human damage due to cracks, breakout, exfoliation and water leakage increases every year. However, domestic research on effect of temperature on road tunnel lining damage is insufficient. Thus, this research has investigated 70 tunnels located in cold region (Gangwon-do) to analyze damage status. Furthermore, by contrasting damage on tunnels in relatively warm Gangneung area with those in relatively cold Hongcheon area, the effect of temperature on road tunnel lining damage was analyzed.

Study on the Frost Damage of Self-Compacting Concrete in Cold Weather Regions (한랭지에 있어서 고류동콘크리트의 동해에 관한 연구)

  • ;;;;Miura, Takashi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.763-766
    • /
    • 1999
  • The objective of this study was to investigate the influence of low temperature curing on resistance of freezing and thawing of self-compacting concrete placed in cold weather regions. The experimental study results indicated that the self-compacting concrete incorporating ground granulated blast-furnace slag showed good resistance to freezing and thawing, and the self-compacting concrete cellulose viscous agent had relatively poor resistance to freezing and thawing.

  • PDF

Heating Performance of Geothermal Heat Pump System Applied in Cold Climate Region(Mongolia) (한랭지(몽골) 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu;Choi, Jae Ho;Min, Kyung Chon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Geothermal heat pump (GHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. These systems use the ground as a heat source in heating mode operation and a heat sink in cooling mode operation. The aim of this study is to evaluate the heating performance of the GHP system for a residential building ($420m^2$) in Ulaanbaatar, Mongolia. In order to demonstrate the feasibility of a sustainable performance of this system, we installed the water-to-water geothermal heat pump with ten vertical ground heat exchangers and measured operation parameters from October 19, 2013 to March 26, 2014. The results showed that the entering source temperature of brine from the ground heat exchangers was in a range of the design target temperature of $-10^{\circ}C$ for heating. For total values of the representative results, the ground heat exchangers extracted heat of 53.51 MWh from the ground. In addition, the GHP system supplied heat of 83.55 MWh to the building and consumed power of 30.27 MWh. Consequently, the average heating seasonal performance factor ($SPF_h$) of the overall system was evaluated to be 2.76 during the measurement period of the heating season.

Origin and Post-depositional Deformation of the Superficial Formations Covering Basalt Plateau in Chungok area (전곡리 용암대지 피복물의 형성과 변화과정)

  • 김남신
    • The Korean Journal of Quaternary Research
    • /
    • v.8 no.1
    • /
    • pp.43-68
    • /
    • 1994
  • 전곡리 일대는 화산지형, 단층지형, 구석기 문화연구 등 여러 분야의 학문적 관심이 집중된 지역이다. 본 연구는 박편 분석, 물리화학 광물분석등이 수단을 활용하여 전곡리 용 암대지를 덮고 있는 피복물의 형성과 퇴적 후의 변화과정을 밝히려고 한 것이다, 여기서 다 음과 같은 사실을 밝힐수 있었다. 전곡리 용암대지는 Riss-Wrm 간빙기에는 별로개석되 지 않았다가 Wrm 빙가에 들어와 인근 황해의 해수면이 낮아지면서 개석된 것으로 추정 된다. 그리고 Wrm빙기 전기간에 걸쳐 용암대지에는 건육화된 황해와 인근 하천(한강, 임 진강) 범람원에서 바람에 의해 날려온 미립물질이 약 8m 이상 퇴적되었다. Wrm 빙기후 기에는 이풍적토(Loess)가 여름에도 녹지 않는 결빙층이 발달했을정도의 한랭 습윤했던 기 후의 영향을 받았다, 이로 인해 일련의 크랙(엽상구조를 이루는 수평크랙과 불규칙한 수직 방향크랙)들이 발달했고 풍적 물질의 미시적 조직과 구조도 많이 변화했다. 또한 결빙작용 으로 변형된 구조의 규제를 받으며 gleyzation 이 진전되었다. 단면 관찰에서 회백색 얼룩과 붉은 또는 검붉은 얼룩이 복잡하게 섞여 있는 모습은 바로 이것이 진전된 결과이다, 그간 발굴된 구석기 유물들은 결빙구조 및 gleyzation의 흔적이 잘 나타나는 부의에서 출토되었 다, 이사실은 본 지역의 구석기 인류가 생활했던 시기는 Wrm 빙기에서도 이러한 한랭 기후가 있기 이전이었음을 시사한다.

  • PDF

Investigation of the yellow sand source region using backward trajectory analysis and TOMS aerosol index. (역궤적 분석과 TOMS 에어로졸 지수를 이용한 황사 발원지 추적)

  • 장건우;조석연
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.43-44
    • /
    • 2002
  • 중국 서북건조 사막지역에서 봄철에 기온이 올라가면서 강한 한랭전선을 동반한 저기압이 발달할 때 그 전선 후면에 미세한 모래먼지가 바람에 휘감겨 올라가 황사가 발생한다. 발원지에서 생성된 황사는 약 30%가 발원지에서 재 침적되고, 20%는 주변지역으로 수송되며, 50%는 편서풍을 타고 1,500-2,000km이상의 거리를 이동하여 우리나라, 일본 및 하와이에까지 침적되는 것으로 알려져 있다. (중략)

  • PDF

A study on the design of tunnel lining insulation based on measurement of temperature in tunnel (터널 온도계측을 통한 라이닝 단열 설계에 관한 연구)

  • Kim, Dea-Young;Lee, Hong-Sung;Sim, Bo-Kyoung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.4
    • /
    • pp.319-345
    • /
    • 2011
  • In case of tunnels in cold regions, a freeze of groundwater around tunnel may act as a barrier of tunnel drainage in winter, or may cause the inner extrusion of lining. In spite of that, a design of insulation for preventing the frost damage of tunnel lining has not been introduced in Korea, while foreign countries such as Norway and so on have a standard on insulation. In this study, a few freezing cases of road tunnels have been reviewed, and the results show that the freezing protection is necessary. In order to characterize the thermal distribution in the tunnel, following measurements have been performed at Hwa-ak tunnel; the temperature distribution by longitudinal lengths, the internal temperature of lining and the temperature distribution of the ground under pavement. From these measurements, the characteristics of the tunnel's internal temperature distribution due to temperature change in the air has been analyzed. Based on the measurement results on the temperature distribution at Hwa-ak tunnel, thermal flow tests on the rock specimen with and without insulation have been performed in the artificial climate chamber to investigate the performance of the insulation. Also, a number of 3D numerical analyses have been performed to propose appropriate insulation and insulation thicknesses for different conditions, which could prevent the frost damage of tunnel lining. As a result of the numerical analysis, air freezing index of 291$^{\circ}C{\cdot}$ Hr has been suggested as the threshold value for freezing criteria of groundwater behind the tunnel lining.

Effects of Theratainment Physical Factors Application on Blood Pressure, Angle and Circumference in an Female University Students Calf (테라테인먼트 물리적 요소 적용이 대학생 여성 종아리의 혈압, 각도, 둘레에 미치는 영향)

  • Lee, Jeong-Uk
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.401-409
    • /
    • 2020
  • This study examined the effect of the application of Theratainment physical factors on the calf blood pressure, ankle angle, and calf circumference. A research sample consisting of normal female university students in their twenties were divided into hot therapy group (n=20), cold therapy group (n=20), and compression therapy group (n=20). By referring to the previous study, 20-minute hot therapy, 15-minute cold therapy, and 30-minute compression therapy with 100mmHg intensity was applied. The therapy was applied to left-side lower limb, followed by the application on the right-side lower limb after an hour of resting time. The calf blood pressure, ankle angle, and calf circumference of each group was assessed. In the study results, hot therapy and compression therapy showed a statistically significant difference on the decrease of blood pressure and increase of ankle angle (p<.05), but cold therapy produced no statistically significant difference. None of the three groups showed a statistically significant difference on the calf circumference. Hence, hot therapy and compression therapy is recommended for reducing calf blood pressure and increasing ankle angle related to the calf. These therapies are expected to be used for solving diverse problems of lower limbs.

Experimental equipment for high efficiency heat pump development by CFD (CFD를 통한 고효율 히트펌프 개발을 위한 실험장치)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1402-1408
    • /
    • 2020
  • In order to save energy, a lot of research has been conducted to develop a high-efficiency heat pump. Research to reduce or eliminate the occurrence of frost in the outdoor unit coil is also being conducted at the same time. A constant temperature chamber was constructed that allows experimentation under the same conditions as in the natural state so that frost does not occur in the outdoor unit of the heat pump regardless of the season. In order to verify the validity of the experimental apparatus, a simulation was conducted by dividing the straight length of the duct in front of the outdoor unit in the constant temperature chamber, which is the experimental apparatus, into three conditions. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.

Optical Extinction Characteristics of Visibility Impairment by Yellow Sand Storm Particles in the Urban Atmosphere of Kwangju (황사현상에 의한 광주시 도시지역 시정감쇄의 광학적 특성)

  • 김영준;김경원;오승진
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.45-46
    • /
    • 2000
  • 황사에 대한 연구는 발원지, 이동경로, 기상조건, 에어로졸의 특성 등 다각적인 면에서 조사되어 왔다. 우리나라에 영향을 미치는 황사현상은 중국 및 몽고 사막 등에서 봄철 기온 상승으로 한랭전선을 동반한 저기압이 발달되어 전선 후면의 강풍과 함께 황토 먼지가 매년 3∼5월경에 편서풍을 타고 3,000 km 이상의 거리를 이동하여 한반도에 유입되는 현상이다. 황사발생일수는 일년에 3∼6일로 주로 4월에 관측되며, 중국의 자료에서도 연중 25 %가 4월에 발생한다고 보고하고 있다(Parungo et al., 1994). (중략)

  • PDF