• Title/Summary/Keyword: 한국대지

Search Result 576, Processing Time 0.023 seconds

Transient Grounding Impedance Characteristics of a Concrete Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 콘크리트봉 접지전극의 과도 접지임피던스 특성)

  • Kim, Kyung-Chul;Kim, Jong-Uk;Lee, Kyu-Jin;Choi, Jong-Ki;Choi, Sun-Kyu;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2010
  • Grounding insures a reference potential point for electric devices and also provides a law resistance path for fault or transient currents in the earth. The grounding impedance as a function of frequency is necessary for determining its performance since fault or transient currents could contain a wide range of frequencies. A concrete rod electrode is one of the commonly used grounding electrodes in electric distribution systems. In this paper, the grounding impedance of concrete rods has been measured in frequency raging from 60[Hz] up to 100[kHz] and an equivalent model of the grounding impedance is identified from the measured values. The grounding impedance under study when a typical lightning surge is injected into the grounding system was simulated numerically and graphically through the use of the EDSA software program.

Analysis of User Satisfaction and Perception on Public Libraries in Complex Facilities in Seoul (서울소재 복합시설 공공도서관에 대한 이용자 만족도 및 인식 분석)

  • Choi, Mun-Jung;Seo, Eun-Gyoung
    • Journal of the Korean Society for information Management
    • /
    • v.33 no.4
    • /
    • pp.77-101
    • /
    • 2016
  • Recently, attention has been drawn to a new form of a public library, that is, a public library in a complex facility constructed in the same building or site with another facility. To get active users' or local governments' supports in the public library in a complex facility, it is necessary to build library strategic plans based on the analysis of users' evaluation and demands. Thus, this study analyzed the user satisfaction and perception of the 28 public libraries in complex facilities in Seoul. As a result, it was found that most users overall satisfied with public libraries in complex facilities in terms of human resources, information resources, and the links among services and positively perceived their environments and services. In order to provide more satisfaction to the users in public libraries in complex facilities first, it is necessary to improve the accessibility of libraries, to secure the sufficient library space, to prevent the outside noise, to link the facilities which bring mutual synergistic effect, and to develop a program and service accompanying other facilities.

A Basic Study on the Attachment Process of Lightning Leader to Ground (낙뢰 리더의 대지부착과정에 대한 기초적 연구)

  • Yoo, Yang-Woo;Kim, Seung-Min;Kim, You-Ha;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.82-88
    • /
    • 2014
  • This paper presents the results of model tests for the attachment process of lightning leader to ground which is one of poorly understood processes of cloud-to-ground lightning discharges. In order to simulate the attachment process of lightning leader to ground, we investigated the discharge characteristics of air gap between the tip of needle-shaped electrode and the soil surface as a parameter of moisture content in soils when the positive and negative $1.2/50{\mu}s$ lightning impulse voltages are applied. The breakdown voltage and the discharge light were observed. As a result, the attachment processes of lightning leader to ground are strongly dependent on the grain size and the moisture content of soils. The time to breakdown was shortened with increasing the magnitude of incident impulse voltages. The delay time from application of the highest voltage to breakdown in sand is shortened with increasing the moisture content. The delay time from application of the voltage to breakdown in gravel varied from about $0.5{\mu}s$ to several ${\mu}s$. As the moisture content in soil increases, the breakdown voltages are decreased and the breakdown voltage versus time to breakdown curves are shifted toward the lower side. The results obtained in this work are similar to those for non-uniform air gap stressed by lightning impulse voltages.

Transient Grounding Impedance Characteristics of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems Using EDSA Program (EDSA 프로그램을 이용한 배전계통에 사용되는 동봉 접지전극의 과도 접지임피던스 특성)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Kim, Min-Sung;Choi, Jong-Kee;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.26-32
    • /
    • 2009
  • Grounding insures a reference potential point for electric devices and also provides a law resistance path for fault or transient currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault or transient currents could contain a wide range of frequencies. A copper rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the grounding impedance of copper rods has been measured in frequency raging from 60[Hz] up to 100 [kHz] and an equivalent model of the grounding impedance is identified from the measured values. The grounding impedance under study when a typical lightning surge is injected into the grounding system was simulated numerically and graphically through the use of the EDSA software program.

A Study on the Mechanization of the Grounding Rod Earth Construction Method to Improve the Grounding Resistance Characteristics (봉형접지극 접지저항 향상을 위한 기계화 시공 연구)

  • Park, Jung-Shin;Cho, Sung-Jae;An, In-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.143-150
    • /
    • 2009
  • The bar-shaped electrode is very popular in earth construction for its easy obtainments of the regulative grounding resistance values on power distribution systems in many countries. For these reason, a lots of researches are being proceeded on its deformation and materials. But the grounding construction has limit for improvement the grounding resistance characteristics not only by the improvement of the driven electrode, because that the grounding characteristics are very sensitive to soils(hard, soft). This study is about the construction methods on which the driven electrode can be serially or parallely connected using by hollow screw rod for obtaining the regulative grounding resistance values. The experimental results show that the grounding resistance values are reduced more than 30[%] comparing with the other construction methods under the same conditions(earth resistance, numbers of driven electrode, construction method of serial and parallel, chemicals for reducing grounding resistance, water).

Evaluations on the Potential Interferences between Ground Rods (봉상 접지전극 상호간의 전위간섭에 대한 평가)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Jung, Hyun-Uk;Kil, Hyung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.92-98
    • /
    • 2006
  • This paper deals with the potential interferences between ground rods. To propose a method for reducing the potential interference caused by grounding electrodes, the theoretical analysis and the reduced scale model tests, which we related to the measurement and computation of ground potential rise and potential interference caused by actual-sized grounding electrodes where current is injected, were carried out. The ground potential rise and potential interference coefficients were measured by using the hemispherical water tank grounding simulator and calculated by CDEGS software as a function of the distance between grounding electrodes. The ground potential rises and potential interference coefficients strongly depend on the distance between grounding electrodes, and the measured results were compared with the computer calculated data and were known in good agreement.

Evaluations of Dangerous Voltages around Grounding Electrode using Small-sized Model (축소모델을 이용한 접지전극 주변의 위험전압 평가)

  • Baek, Young-Hwan;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.83-88
    • /
    • 2010
  • In this paper, to propose a valid method solving a problem relevant to grounding from actual field data, the experimental results relevant to touch and step voltages and surface potential profiles measured around the real-sized and small-sized grounding electrode models were described. The ground surface potential profiles and dangerous voltages around the concrete pedestals employed in street facilities such as street lamps, traffic signal lamp and controllers as a case study were measured and discussed. The hemispherical cell with a diameter of 1,160[mm] was employed to simulate uniform soil. As a result, the results measured with the small-sized model were in reasonably agreement with the data obtained from the real-sized installation. It was found that the small-sized model test could be employed as a useful means evaluating the dangerous voltages around grounding electrodes installed at the inaccessible areas such as mountains, underground, underwater, and so on.

Seasonal Incidence of Potato virus f Infection on Potato Cultivars for the Double Crops in Korea (2기작 감자 품종의 재배 시기별 PVY 감염 정도 조사)

  • Hahm Young-Il;Lee Young-Gyu
    • Research in Plant Disease
    • /
    • v.12 no.1
    • /
    • pp.28-31
    • /
    • 2006
  • One of major potato viruses is Potato virus Y (PVY) in Korea. In the southern part of Korea, potatoes have been grown as double crops in a year by using cv. 'Dejima' and 'Chubak' due to very short dormancy. However, they have caused a serious problem such as a rapid degeneration. It has been thought that the degeneration is affected by the high incidence of PVY in neighboring potato fields. Therefore, the investigation of factors causing the degeneration is very important in the production of healthy seed potato. In this study, the PVY reinfection rates of several potato varieties and the different seed sources of cv. 'Chubak' have been investigated. Results show that the lowest infection rate of PVY among four potato cultivars derived from minitubers is cv. 'Superior'. The others are in order of 'Dejima', 'Atlantic' and 'Chubak'. Also, the incidences of PVY differ significantly when several seed sources are examined. When the seed potatoes (G2, the progeny of microtuber) as spring potato crops are planted in area without potato field nearby, the infection rate of PVY is as low as that of microtubers. However, PVY incidence in the progenies of minitubers as fall potato crops largely increases. Therefore, the best way of potato production under double cropping system is to use the healthy seed potato produced in area without potato field and plant relatively resistant cultivar such as Dejima.

Approximate Solution for Constant Velocity of Archimedean Spiral for Abrasion Testing of Rock Cutting Tools (암석공구 마모시험을 위한 아르키메데스 나선의 등속도 운동 근사해 조사)

  • Kang, Hoon;Kim, Dae-ji;Song, Changheon;Oh, Joo-Young;Cho, Jung-Woo
    • Tunnel and Underground Space
    • /
    • v.30 no.3
    • /
    • pp.181-192
    • /
    • 2020
  • Pin-on-disk test is a suggested abrasion testing method by ASTM (American Society for Testing and Materials). This briefly illustrated the Archimedean spiral motion of a pin type specimen on a disk. To apply this method to rock cutting tools, a constant linear velocity (CLV) is precisely maintained during the test. We defined the two velocity vectors (RPM and horizontal speed) which connected to the resultatnt velocity. We derived a differential equations for the two parameters under CLV condition. It was difficult to find a exact solution. Previous literatures had been reviewed, and an approximate solution was investigated. We mathematically simulated the result for a certain parameter, and examine the accuracy of the solution.

Calculation Method of Constant Linear Velocity Spiral Path for Pin-on-disk Abrasion Test using a Hollow Type Rock Sample (중공형 암석시편의 Pin-on-disk 마모시험을 위한 등속도 나선경로 계산방법)

  • Kang, Hoon;Kim, Dae-ji;Song, Changheon;Oh, Joo-Young;Cho, Jung-Woo
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.394-403
    • /
    • 2020
  • This technical note describes the calculation method of continuous constant linear velocity Archimedean spiral paths which are applied to the pin-on-disk abrasion test. Approximate constant linear velocity Archimedean spirals have unstable velocities in the very near region of the rotational origin. Thus, in this technical note, the offset distance from the rotational origin was given by using a hollow type rock sample to maintain the constant velocity during the test. Also, to connect the inward and outward spirals continuously, the information of start and end points were input on the next spiral path consecutively. Furthermore, the calculation program was developed to provide convenience for calculating constant linear velocity spirals according to the specimen dimension and abrasion test conditions.