• Title/Summary/Keyword: 하중(load)

Search Result 6,804, Processing Time 0.03 seconds

A Study on Live Load Design Standards Considering Moving Load (For Shorter than 60m Span) (이동하중을 고려한 활하중 설계기준 연구 (60m 이하 교량))

  • Jin, Kyung Seok;Han, Man Yop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1261-1270
    • /
    • 2013
  • The current domestic design criteria of live load employs DL-24 load and DB-24 load. Particularly for long span bridges above 45meters, DL-24 load is forced to apply and design them, since the shearing force and the moment of DL-24 load appears more dominate than those of DB-24. But it appeared that this DL-24 load didn't meet the vehicles traveling load, which affected bridges in real use. Hence this paper defined ML-24 load similar to the load applied to real bridges and also defined a new live load model, RL-24 load, after adjusting the existing DL-24 load, which doesn't meet the moment and the shearing force of ML-24. As the result of applying and reviewing RL-24 load to simple bridges of span of 45~60m, the results satisfying both the moment and the shearing force applied to bridges in real use by traveling load were attained. Besides, the applicability of it was examined in comparison with live load models of home and abroad.

Transformation of Flight Load to Test Load for the Static Load Test of External Fuel Tank for Aircraft (항공기용 외부연료탱크 정하중시험을 위한 비행하중의 시험하중으로의 변환)

  • Kim, Hyun-gi;Kim, Sung Chan;Park, Sung Hwan;Ha, Byoung Geun;An, Su Hong;Kim, Jun Tae
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.1
    • /
    • pp.80-85
    • /
    • 2021
  • In this study, for conducting a static load test of an external fuel tank used for an aircraft, the flight load acting on the external fuel tank was converted to the test load and the suitability of the converted test loads was confirmed. In order to calculate the test load from the flight load, the external fuel tank was divided into several sections. Shear load, moment by unit shear load, and unit moment were calculated for each section. Test loads for each section were then calculated by computing the shear load, the moment of each section, and flight load condition. In actual static load tests, it might not be possible to impose the test load in the calculated position due to physical constraints. Therefore, after determining positions in which the load could be imposed in the actual test, the test load calculated for each section was redistributed to selected positions. Finally, a test load plan was established by applying a whiffle tree to enhance the efficiency of the test performance while making it easier to operate the actuator. The reliability of the test load plan was verified by comparing it with flight load conditions.

An Applicative Estimation of Safety Factors about Driven Pile Using the Results of Static Loading Test on the Ultimate State (극한상태의 정재하시험결과를 이용한 타입말뚝의 안전율 적용성 평가)

  • Ki, Wan-Seo;Park, Noh-Hwan;Kim, Sun-Hak
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.441-457
    • /
    • 2009
  • This study estimated ultimate load by the determination methods based on ultimate load, yield load and settlement using experimental data from static load tests that applied load to driven piles used in sandy grounds at home and overseas until failure appeared markedly. Estimated ultimate load was normalized with actually measured failure load, and was compared among the determination methods according to the characteristics of pile. In addition, I have identified to the determination methods suitable for estimating ultimate load, and reevaluated the safety factor when determining allowable load. From the results of this study were drawn conclusions as follows. Among ultimate loads estimated by the ultimate-load-based determination methods, the value interpreted by Chin's method tended to overestimate actual measurements, and B. Hansen 80% standard and the stability plot method were considered most reliable as their results were closest to actual measurements. According to the results of this study, in calculating the allowable load, if the safety factor to be applied to failing load obtained by the method of determining extreme load is converted to the safety factor applied to the Standards for Structure Foundation Design, a value larger than 3.0 should be applied except the B. Hansen 90% method, and a value larger than 2.0 should be applied in the methods of determining yield load. In addition, if the safety factor to be applied to load obtained by the settlement standard is converted based on safety factor 3.0 for extreme load, a value smaller than 3.0 should be applied to the total settlement standard and the net settlement standard.

Characteristics of Load-Settlement Behaviour for Embeded Piles Using Load-Transfer Mechanism (하중전이기법을 이용한 매입말뚝의 하중-침하 거동특성)

  • Oh, Se Wook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.4
    • /
    • pp.51-61
    • /
    • 2001
  • A series of model tests and analyses by load transfer function were performed to study load-settlement behaviour with relative compaction ratio of soil and embeded depth of pile. In the model tests, embeded depth ratio(L/D) of pile were installed 15, 20, 25 and relative compaction of soil(RC) is 85%, 95% and then cement were injected at around perimeter of pile. For analysis of embedded pile, the paper were compared results of model tests with analysis results by Vijayvergiya model and Castelli model, Gwizdala model of elastic plasticity-perfect plastic model and then the fitness load transfer mechanism was proposed to predict load-settlement behaviour of embeded pile. The analysis results of predicted bearing capacity by load transfer function, ultimate bearing capacity of embeded pile were approached to measured value and behaviour of initial load-settlement curve were estimated that load transfer function by Castelli were similar to measured value. The result of axial load analysis of bored pile shows that skin friction estimated by load transfer mechanism is investigated more a little than that of measured values.

  • PDF

A Study on Effect Factor of Load Transfer Efficiency in Concrete Pavement (콘크리트포장에서 하중전달효과 영향인자 연구)

  • Yang, Hong-Suk;Suh, Young-Chan;Kwon, Soo-Ahn
    • International Journal of Highway Engineering
    • /
    • v.3 no.3 s.9
    • /
    • pp.147-158
    • /
    • 2001
  • One of the most important factors accounting for the structural capacity of concrete pavement is load transfer efficiency. Load transfer efficiency is affected by slab temperature gradient, construction of dowel bars, degree of aging, and crack width. The purpose of this study is to determine the patterns of load transfer efficiency of concrete pavement; to determine the factors that affect the load transfer efficiency; and to present the proper measuring method of load transfer efficiency. As a result from this study, load transfer efficiency was affected primarily by the average temperature in concrete slab. Load transfer efficiency decreased with decreasing temperature and increasing crack width. For the sections with dowel bars, there were little differences in load transfer efficiency regardless of temperature changes. For the sections without dowel bars, however, there on great losses of load transfer efficiency at low temperatures. For the old pavement, even in the sections with dowel bars, the load transfer efficiency reduced as the temperature dropped For the sections in this study, 1.4% reduction of the load transfer efficiency was observed for each $1^{\circ}C$ drop in the slab temperature.

  • PDF

A Deterministic Investigation for Establishing Design Load of Railway Bridges (표준열차하중 수립을 위한 결정론적 분석)

  • Kim, Sung-Il;Kim, Hyun-Min;Lee, Myung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.3
    • /
    • pp.290-297
    • /
    • 2010
  • At present, the design live load of railway is divided into common railway and high speed railway separately in Korea. L22 which is based on American railway standards is used for common railway and HL25 which is based on Eurocode is used for high speed railway. Although, the design load is the starting point for design of railway, any research for developing design load does not exist at all. However, Europe and Japan develops the design load model consistently for advanced design. Recently, deterministic, probabilistic and cost performance approaches are investigated for developing new design load in Europe which is called LM2000. In the present paper, as a step for developing new design live load model for Korean railway, deterministic processes will be introduced. The safety margins are analyzed based on serviced real trains versus proposed new design load model and a necessity for new design live load will be presented quantitatively.

Prediction of Ultimate Load of Drilled Shafts Embedded in Weathered Rock by Extrapolation Method (외삽법을 이용한 풍화암에 근입된 현장타설말뚝의 극한하중 예측)

  • Jung, Sung Jun;Lee, Sang In;Jeon, Jong Woo;Kim, Myoung Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4C
    • /
    • pp.145-151
    • /
    • 2009
  • In general, a drilled shaft embedded in weathered rock has a large load bearing capacity. Therefore, most of the load tests are performed only up to the load level that confirms the pile design load capacity, and stopped much before the ultimate load of the pile is attained. If a reliable ultimate load value can be extracted from the premature load test data, it will be possible to greatly improve economic efficiency as well as pile design quality. The main purpose of this study is to propose a method for judging the reliability of the ultimate load of piles that is obtained from extrapolated load test data. To this aim, ten static load test data of load-displacement curves were obtained from testing of piles to their failures from 3 different field sites. For each load-displacement curve, loading was assumed as 25%, 50%, 60%, 70%, 80%, and 90% of the actual pile bearing capacity. The limited known data were then extrapolated using the hyperbolic function, and the ultimate capacity was re-determined for each extrapolated data by the Davisson method (1972). Statistical analysis was performed on the reliability of the re-evaluated ultimate loads. The results showed that if the ratio of the maximum-available displacement to the predicted displacement exceeds 0.6, the extrapolated ultimate load may be regarded as reliable, having less than a conservative 20% error on average. The applicability of the proposed method of judgment was also verified with static load test data of driven piles.

Tensile Load Transmission Capacity of H-shaped Beam by Stud Connectors (스터드 커넥터로 연결된 H형강보의 인장하중 전달성능)

  • Lee, Myung Jae;Choi, Wan Chol;Kim, Won Ki;Kim, Jae Hee;Lee, Sang Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.267-274
    • /
    • 2004
  • The objective of this study is to evaluate tensile load transmission capacity of H-shaped beam about design load by stud connector. The basic test of stud connecter was conducted and two specimens of full-scale size were tested under monotonic tensile loading condition. The parameter of tests is the size of the H-shaped beams. The results show that tensile load transmission capacity of H-shape beam about design load by stud connectors is excellent observing to the design code of steel structures of Architectural Institute of Korea.

Analysis of a Bi-directional Load Test Result on tong PHC Piles in Consideration of Residual Load (잔류하중을 고려한 장대 PHC 말뚝의 양방향 재하시험 결과해석)

  • Kim, Sung-Ryul;Chung, Sung-Gyo;Lee, Bong-Yeol
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.6
    • /
    • pp.85-93
    • /
    • 2008
  • For long piles driven in deep clay deposits, it is difficult to estimate the ultimate bearing capacity due to large resistance induced by long embedded depth, and also the load transfer curve due to large residual load induced by negative skin friction, even with the performance of pile load tests. In this research, a hi-directional load test on a PHC pile driven in deep soft deposit was performed in order to evaluate the tip and shaft resistances separately, which are feasible to estimate the ultimate bearing capacity of the pile. Residual load of the pile was determined by continuous monitoring of pile strains after the pile installation. The true resistance and true load-movement curve of the pile were properly estimated by taking account of the residual load. A model far behavior of the shaft resistance vs. movement was also proposed, which includes the effects of residual load based on the experiment. Consequently, it was proved that the residual load should be taken into consideration for correctly analyzing load test results of piles in deep clay deposits.

Probabilistic Analysis of Lifetime Extreme Live Loads in Office Buildings (사무실의 사용기간 최대 적재하중에 대한 확률론적 분석)

  • 김상효;조형근;배규웅;박흥석
    • Computational Structural Engineering
    • /
    • v.3 no.1
    • /
    • pp.109-116
    • /
    • 1990
  • Live load data in domestic office buildings have been collected in a systematic manner. Based on surveyed data, equivalent uniformly distributed load intensities, which produce the same load effect as the actual spatially varying, live load, have been obtained for various structural members (such as slab, beam, column, etc. ). Influence surface method has been employed to compute load effects under real live load, including beam moment, slab moment as well as axial force in column. The results have been examined to find probabilistic characteristics and relationship between influence area and load intensity (or coefficient of variation). The results were also compared with other survey results and found to be reasonable. Based on the probabilistic load models obtained, the lifetime extreme values have been analyzed and compared with current design loads. Tentative equations applicable to decide more rational design loads are also suggested as functions of influence area.

  • PDF