• Title/Summary/Keyword: 하강신호

Search Result 61, Processing Time 0.027 seconds

PSPICE circuit simulation for electrical characteristic analysis of the memristor (멤리스터의 전기적 특성 분석을 위한 PSPICE 회로 해석)

  • Kim, Boo-Kang;Park, Ho-Jong;Park, Yongsu;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1051-1058
    • /
    • 2014
  • This paper presents a Electrical characteristics of the Memristor device using the PSPICE for circuit analysis. After making macro model of the Memristor device for circuit analysis, electric characteristics of the model such as time analysis, frequency and DC analysis according to the input voltage were performed by PSPICE simulation. Also, we made simple circuits of memristor series and parallel structure and analyzed the simulated SPICE results. Finally, we made a memristor-capacitor (M-C) circuit. charge and discharge characteristics were analyzed. In case of input pulse signal of 250 Hz, the Memristor-capacitor circuit showed delay time of 0.6ms, rising time of 0.58 ms and falling time of 1.6 ms.

Design and Fabrication of a High-Power Pulsed TWTA for Millimeter-Wave(Ka-Band) Multi-Mode Seeker (밀리미터파(Ka 밴드) 복합모드 탐색기용 고출력 펄스형 진행파관 증폭기(TWTA) 설계 및 제작)

  • Song, Sung-Chan;Kim, Sun-Ki;Lee, Sung-Wook;Min, Seong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.307-313
    • /
    • 2019
  • The traveling wave tube amplifier (TWTA), which can be applied to the Ka-band millimeter-wave multi-mode seeker, consists of an high voltage power supply(HVPS), a grid modulator, a command and control, and an RF assembly. We designed a power supply that generates a -17.9 kV high voltage by synchronizing the pulse repetition frequency(PRF) and power supply switching frequency(i.e. synchronization frequency), and a high-speed grid-switching modulator for RF pulse modulation. The TWTA, which is fabricated through miniaturization with a volume of 3.18 L, has high pulse switching characteristics of up to 18.5 ns. The maximum rise/fall time of the grid on/bias signal and peak power is more than 564.9 W. Moreover, an excellent spurious performance of -68.4 dBc or less was confirmed within the range of PRF and PRF/2.

An I/O Interface Circuit Using CTR Code to Reduce Number of I/O Pins (CTR 코드를 사용한 I/O 핀 수를 감소 시킬 수 있는 인터페이스 회로)

  • Kim, Jun-Bae;Kwon, Oh-Kyong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.47-56
    • /
    • 1999
  • As the density of logic gates of VLSI chips has rapidly increased, more number of I/O pins has been required. This results in bigger package size and higher packager cost. The package cost is higher than the cost of bare chips for high I/O count VLSI chips. As the density of logic gates increases, the reduction method of the number of I/O pins for a given complexity of logic gates is required. In this paper, we propose the novel I/O interface circuit using CTR (Constant-Transition-Rate) code to reduce 50% of the number of I/O pins. The rising and falling edges of the symbol pulse of CTR codes contain 2-bit digital data, respectively. Since each symbol of the proposed CTR codes contains 4-bit digital data, the symbol rate can be reduced by the factor of 2 compared with the conventional I/O interface circuit. Also, the simultaneous switching noise(SSN) can be reduced because the transition rate is constant and the transition point of the symbols is widely distributed. The channel encoder is implemented only logic circuits and the circuit of the channel decoder is designed using the over-sampling method. The proper operation of the designed I/O interface circuit was verified using. HSPICE simulation with 0.6 m CMOS SPICE parameters. The simulation results indicate that the data transmission rate of the proposed circuit using 0.6 m CMOS technology is more than 200 Mbps/pin. We implemented the proposed circuit using Altera's FPGA and confimed the operation with the data transfer rate of 22.5 Mbps/pin.

  • PDF

A Feasibility Study of Earthquake Monitoring Using a High-resolution Borehole Strainmeter (고분해능 시추공 변형률계 활용을 통한 지진 연구 가능성)

  • Soh, Inho;Chang, Chandong
    • The Journal of Engineering Geology
    • /
    • v.26 no.2
    • /
    • pp.177-185
    • /
    • 2016
  • This work investigates whether stress changes induced by an earthquake can be estimated using the deformation measured by high-resolution borehole strainmeters. We estimate the changes in the orientation and magnitude of the principal compression stresses using borehole strainmeter data recorded before and after the M7.2 El Mayor-Cucapah earthquake on April 4, 2010. Clear differences in the stress orientations and magnitudes are apparent before and after the event. The change in stress orientation appears related to subtle increases of stress in the tectonic maximum principal orientation, which is in agreement with the earthquake focal mechanism solution. The sudden stress drop at the onset of the earthquake was 10−3-10−2 MPa in the principal orientations. The Coulomb stress transfer model, which can estimate stress transfer, predicts a shear stress increase of (0.1-0.6) × 10−2 MPa at the strainmeter site, which is in line with the measured data (0.3-0.8) × 10−2 MPa. Overall, our results suggest that borehole strainmeter data reflect the subtle stress changes associated with earthquake occurrence, and that such data can be utilized for earthquake-related research.

Seismic reflection survey in a tidal flat: A case study for the Mineopo area (갯벌 지역에서의 탄성파 탐사: 민어포 조간대 지역의 사례)

  • Jou Hyeong-Tae;Kim Han-Joon;Lee Gwang-Hoon;Choi Dong-Lim;Kim Min-Ji;Cho Hyun-Moo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.67-84
    • /
    • 2002
  • A shallow high-resolution seismic reflection survey was carried out at the Mineopo tidal flat on the western coast of Korea. The purpose of the survey was to investigate shallow sedimentary structure of the tidal (fat associated with the recent sea level change. A total of 795 shots were generated at 1 m interval from a 5-kg hammer source and recorded on 48 channels of 100 Hz geophones along two mutually perpendicular profiles. The water-saturated ground condition resulted in suppressed ground rolls by significantly decreasing rigidity. In addition, seismic velocities over 1500 m/s provided easy segregation of reflected arrivals from lower velocity noise. As a consequence, seismic sections were created that are high in resolution and signal to noise ratio as well. The stack sections show that the tidal flat consists of 5 sedimentary sequences above acoustic basement. Although deposition is largely characterized by the transgressive sedimentary facies resulting from sea level rise, erosional surfaces are well-resolved within the sequences.

  • PDF

Clinicoradiologic Characteristics of Intradural Extramedullary Conventional Spinal Ependymoma (경막내 척수외 뇌실막세포종의 임상 영상의학적 특징)

  • Seung Hyun Lee;Yoon Jin Cha;Yong Eun Cho;Mina Park;Bio Joo;Sang Hyun Suh;Sung Jun Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1066-1079
    • /
    • 2023
  • Purpose Distinguishing intradural extramedullary (IDEM) spinal ependymoma from myxopapillary ependymoma is challenging due to the location of IDEM spinal ependymoma. This study aimed to investigate the utility of clinical and MR imaging features for differentiating between IDEM spinal and myxopapillary ependymomas. Materials and Methods We compared tumor size, longitudinal/axial location, enhancement degree/pattern, tumor margin, signal intensity (SI) of the tumor on T2-weighted images and T1-weighted image (T1WI), increased cerebrospinal fluid (CSF) SI caudal to the tumor on T1WI, and CSF dissemination of pathologically confirmed 12 IDEM spinal and 10 myxopapillary ependymomas. Furthermore, classification and regression tree (CART) was performed to identify the clinical and MR features for differentiating between IDEM spinal and myxopapillary ependymomas. Results Patients with IDEM spinal ependymomas were older than those with myxopapillary ependymomas (48 years vs. 29.5 years, p < 0.05). A high SI of the tumor on T1W1 was more frequently observed in IDEM spinal ependymomas than in myxopapillary ependymomas (p = 0.02). Conversely, myxopapillary ependymomas show CSF dissemination. Increased CSF SI caudal to the tumor on T1WI was observed more frequently in myxopapillary ependymomas than in IDEM spinal ependymomas (p < 0.05). Dissemination to the CSF space and increased CSF SI caudal to the tumor on T1WI were the most important variables in CART analysis. Conclusion Clinical and radiological variables may help differentiate between IDEM spinal and myxopapillary ependymomas.

A Study on the Telemetry System for the Inhabitant Environment and Distribution of Fish-III -Oxygen, pH, Turbidity and Distribution of Fishes- (어류의 서식환경과 분포생태의 원격계측에 관한 연구 -III -$용존산\cdot$pH 및 독도와 어류의 분포생태-)

  • 신형일;안영화;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.136-146
    • /
    • 1999
  • The telemetry system for the oxygen, pH, turbidity and the distribution ecology of fishes was constructed by the authors in order to product and manage effectively in shallow sea culture and setnets fisheries, and then the experiments for the telemetry system carried out at the culturing fishing ground in coast of Sanyang-Myon, Kyoungsangnam-Do and the set net fishing ground located Nungpo bay in Kojedo province respectively from October, 1997 to June 1998.As those results, the techniques suggested in the telemetry system for which find out the relationship between the physical and chemical environment in the sea and the distribution ecology of fishes gave full display its function, and its system could be operated as real time system. This research can also provide base-line data to develope a hybrid system unifying the marine environment information and the fisheries resources information in order to manage effectively coastal fishing ground.

  • PDF

Fabrication of a PMN-PZT needle hydrophone for photoacoustic imaging (광음향 영상화를 위한 PMN-PZT 바늘형 수중청음기 제작)

  • Fan, Xiaofeng;Cao, Yonggang;Ha, Kanglyeol;Kim, Moojoon;Kang, Hyun Wook;Oh, Junghwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.175-182
    • /
    • 2016
  • For application to several MHz photoacoustic imaging systems, a needle hydrophone was designed and fabricated by using PMN-PZT piezoelectric single crystal, and its characteristics were evaluated through comparison with a commercial PVDF(Polybinylidene Fluoride) hydrophone of which receiving sensitivity is known. The simulation using the KLM model results show that the peak receiving impulse response for $50{\Omega}$ terminating impedance of the fabricated hydrophone is -261.6 dB re $1V/{\mu}Pa$ and the frequency response is relatively flat over 2 ~ 12 MHz with fluctuation less than 5 dB. The measurement results using tone burst signals also show that it has higher (ave. 10.9 dB) sensitivity than the commercial hydrophone in 2 ~ 8 MHz, and the receiving sensitivity of $-255.8{\pm}2.8$ dB re $1V/{\mu}Pa$ was measured for the fabricated hydrophone. In addition, it is known that the photoacoustic signals and the image of a hair obtained by a mechanical scanned photoacoustic imaging system with the fabricated hydrophone were bigger and better than those obtained with the commercial hydrophone.

Improving the Accuracy of the Tapped Delay Time-to-Digital Converter Using Field Programmable Gate Array (Field-Programmable Gate Array를 사용한 탭 딜레이 방식 시간-디지털 변환기의 정밀도 향상에 관한 연구)

  • Jung, Do-Hwan;Lim, Hansang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.182-189
    • /
    • 2014
  • A tapped delay line time-to-digital converter (TDC) can be easily implemented using internal carry chains in a field-programmable gate array, and hence, its use is widespread. However, the tapped delay line TDC suffers from performance degradation because of differences in the delay times of dedicated carry chains. In this paper, a dual edge measurement method is proposed instead of a typical step signal to the delay cell to compensate for the performance degradation caused by wide-delay cells in carry chains. By applying a pulse of a fixed width as an input to the carry chains and using the time information between the up and down edges of the signal pulse, the timing accuracy can be increased. Two dedicated carry chain sites are required for the dual edge measurements. By adopting the proposed dual edge measurement method, the average delay widths of the two carry chains were improved by more than 35%, from 17.3 ps and 16.7 ps to 11.2 ps and 10.1 ps, respectively. In addition, the maximum delay times were improved from 41.4 ps and 42.1 ps to 20.1 ps and 20.8 ps, respectively.

Design of a Clock and Data Recovery Circuit Using the Multi-point Phase Detector (다중점 위상검출기를 이용한 클럭 및 데이터 복원회로 설계)

  • Yoo, Sun-Geon;Kim, Seok-Man;Kim, Doo-Hwan;Cho, Kyoung-Rok
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.72-80
    • /
    • 2010
  • The 1Gbps clock and data recovery (CDR) circuit using the proposed multi-point phase detector (PD) is presented. The proposed phase detector generates up/down signals comparing 3-point that is data transition point and clock rising/falling edge. The conventional PD uses the pulse width modulation (PWM) that controls the voltage controlled oscillator (VCO) using the width of a pulse period's multiple. However, the proposed PD uses the pulse number modulation (PNM) that regulates the VCO with the number of half clock cycle pulse. Therefore the proposed PD can controls VCO preciously and reduces the jitter. The CDR circuit is tested using 1Gbps $2^{31}-1$ pseudo random bit sequence (PRBS) input data. The designed CDR circuit shows that is capable of recovering clock and data at rates of 1Gbps. The recovered clock jitter is 7.36ps at 1GHz and the total power consumption is about 12mW. The proposed circuit is implemented using a 0.18um CMOS process under 1.8V supply.