• Title/Summary/Keyword: 필름카세트

Search Result 9, Processing Time 0.031 seconds

Disinfection Effect of Film Cassettes by Ultraviolet Irradiation (자외선을 이용한 Film Cassette의 소독 효과)

  • Kweon, Dae-Cheol;Park, Peom
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.425-432
    • /
    • 2001
  • A bacteria infection on film cassette contact surface was examined at the diagnostic radiology department. Studies have demonstrated a bactericidal effect of ultraviolet irradiation, and to assess the contamination level on film cassette contact surface as a predictor of patient prevent from nosocomial infection. The study showed that the laboratory result was identified non-pathologic and pathologic bacterial in the five different cassette size of the contact surface. Film cassettes were exposed to ultraviolet light for 1, 2 and 3 minutes. Ultraviolet light disinfection practices suitable for bacteria. The study concludes that presence of a bacterial infection will prevent a using antiseptic technique on film cassette contact surface. In conclusion, ultraviolet irradiate on film cassette over the surface more than 2 minutes. Ultraviolet dose of $1565 {\mu}W{\codt}s/cm^2$ Win in 30 second relative to ultraviolet dose in time.

  • PDF

Contemplation on Usefulness of Plane Cone for Taking Image of Intercondyloid Fossa (무릎 과간와(Intercondyloid fossa) 촬영용 평면 Cone의 유용성에 대한 고찰)

  • Shin, WoonJae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.501-508
    • /
    • 2015
  • There are various Intercondyloid fossa X-ray taking methods. The methods carried out in clinics are Holmblad method, Camp-Conventry method, and Beclere method. Taking image of Intercondyloid fossa is carried a lot as basic examination for diagnosis related to simple fracture and cruciate ligament. Considering the condition and pains of patients, safe method is chosen but because Holmblad method can cause pains to knee part adhering to cassette, it is not easily used. In this study self-produced plane circular cone was attached to a cassette and in the posture for Holmblad method questionnaires of 100 applicants were analyzed to understand cognition on alleviation of pains, and the concentration of imge quality by scattering rays was measured with densitometer by taking human body phantom with X-ray. As a result, in the posture for Holmblad method, cognition on pains was alleviated by average 99%, and the change of concentration of X-ray film taken using phantom by scattering rays decreased statistically significantly compared to the cassette which did not use self-produced plane cone, therefor it is thought that the method can be valuably used in clinics.

Setting Up a CR Based Filmless Environment for the Radiation Oncology (CR 시스템을 이용한 방사선 종양학과의 Filmless 환경 구축)

  • Kim, Dong-Young;Lee, Ji-Hae;Kim, Myung-Soo;Ha, Bo-Ram;Lee, Cheon-Hee;Kim, So-Yeong;Ahn, So-Hyun;Lee, Re-Na
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.155-162
    • /
    • 2011
  • The analog image based system consisted of a simulator and medical linear accelerator (LINAC) for radiotherapy was upgraded to digital medical image based system by exchanging the X-ray film with Computed Radiography (CR). With minimum equipments shift and similar treatment process, it was possible that the new digital image system was adapted by the users in short time. The film cassette and the film developer device were substituted with a CR cassette and a CR Reader, where the ViewBox was replaced with a small size PC and a monitor. The viewer software suitable for radiotherapy was developed to maximize the benefit of digital image, and as the result the convenience and the effectiveness was improved. It has two windows to display two different images in the same time and equipped various search capability, contouring, window leveling, image resizing, translation, rotation and registration functions. In order to avoid any discontinuance of the treatment while the transition to digital image, the film and the CR was used together for 1 week, and then the film developer was removed. Since then the CR System has been operated stably for 2 months, and the various requests from users have been reflected to improve the system.

Evaluation of Tissue Inhomogeneity for Gamma-knife Radiosurgery Using Film Dosimetry (감마 나이프 방사선 수술시 필름 선량 측정에 의한 조직 불균일성에 대한 연구)

  • Cho, Heung-Lae;Shon, Seung-Chang;Shu, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.325-335
    • /
    • 1998
  • Purpose : Since the mid cranial fossa is composed of various thickness of bone, the tissue inhomogeneity caused by bone would produce dose attenuation in cobalt-60 gamma knife irradiation. The correction factor for bone attenuation of cobalt-60 which is used for gamma knife source is -3.5$\%$. More importantly, nearly all the radiosurgery treatment planning systems assume a treatment volume of unit density: any perturbation due to tissue inhomogeneity is neglected, This study was performed to confirm the bone attenuation in mid cranial fossa using gamma knife. Materials and Methods : Computed tomography was performed after Leksell stereotactic frame had been liked to the Alderson Rando Phantom (human phantom) skull area. Kodak X-omat V film was inserted into two sites of pituitary adenoma point and acoustic neurinoma point, and irradiated by gamma knife with 14mm and 18mm collimator. An automatic scanning densitometer with a 1mm aperture is used to measure the dose profile along the x and y axis. Results : Isodose curve constriction in mid cranial fossa is observed with various ranges. Pituitary tumor point is greater than acoustic neurinoma point (0.2-3.0 mm vs 0.1-1.3 mm) and generally 14 mm collimator is greater than 18mm collimator (0.4-3.0 mm vs. 0.2-2.2 mm) Even though the isodose constriction is found, constriction of 50$\%$ isodose curve which is used for treatment reference line does not exceed 1 mm. This range is too small to influence the treatment planning and treatment results. Conclusion : Radiosurgery planning system of gamma knife does not show significant error to be corrected without consideration of bone attenuation.

  • PDF

Comparison of the Food and Nutrition Curriculum As a Teaching Plan Provided by the Ministry of Education and the Actual Teaching Plan by teachers in Incheon. Korea (실과의 식품영양 단원의 교사용 지침서와 실제 수업과의 비교 연구 -인천직할시 공립국민학교를 중심으로-)

  • 김수자
    • Journal of Korean Home Economics Education Association
    • /
    • v.5 no.1
    • /
    • pp.87-95
    • /
    • 1993
  • 본 연구는 교육부에서 의도하는 국민학교 실과 과목의 식품영양 단원의 지침서 내용과 현장에서의 교사 수업 실태를 교육관련 전문지인 새교육, 새교실, 새수업등에 게재된 현장교사들의 지도안 내용과 인천시내 공립국민학교 교사 510명과 학생 1,754명을 대상으로 설문조사를 통한 내용을 분석하였는데 그 결과는 다음과 같다. 1. 교사용 지침서에 제시된 교과목표 및 단원 내용과 현장 교사들의 지도안 내용은 완전일치 하였다. 2. 교육부가 제시한 수업시수가 알맞다는 응답이 4학년 88.7%, 5학년 87.4%, 6학년은 87.8%였으나 약 10%정도의 교사는 식품 영양단원에 더 시간이 필요하다고 응답하였고. 현재의 시간을 줄여야 한다는 응답도 4학년 0.8% 5학년 2.6% 6학년 2.4%나 되었다 또한 28-38%의 교사가 실과시간을 다른시간으로 활용한 적이 있다고 응답하였으며 3번이상 다른시간으로 쓴 경우도 4학년 6.5%, 5,6학년은 11%나 되었다. 3. 교육부가 제시한 교수방법보다 다양한 교수방법이 현장에서 실시되고 있었으나 가장 많이 사용되는 교수방법은 4, 5, 6,학년 모두 설명, 발표 판서, 교과서 읽기 등이었고 실험 조사, 역할 놀이, 토의, 시범 등은 드물게, 필름이나 슬라이드, 카세트 등은 거의 사용하지 않는 것으로 나타났다. 4. 사용된 학습자료로는 교과서, 교사용 지침서, 학습 과제장 등이 주된것이었으며 그 이외의 자료는 극히 활용도가 미약하였다. 5. 실험 실습을 위한 실습은 전혀 갖추고 있지 못한 실정이었으며, 조리 실습은 학생들이 재료와 도구등을 준비(4학년 96.5%, 5학년 96.1% 6학년 95.7%)하여 실시하고 있는 것으로 나타났다.

  • PDF

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

하부전극 물질에 따른 CdTe박막 증착과 그에 따른 전기적 특성 평가

  • Kim, Dae-Guk;Sin, Jeong-Uk;Lee, Yeong-Gyu;Kim, Seong-Heon;Lee, Geon-Hwan;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.327-328
    • /
    • 2012
  • 의료분야의 진단 방사선 장비는 초기의 필름방식 및 카세트에서 진보되어 현재는 디지털방식의 DR (Digital Radiography)이 널리 사용되며 이에 관한 연구개발이 활발히 진행 되고 있다. DR은 일반적으로 직접방식과 간접방식으로 나눌 수 있다. 직접방식의 원리는 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 전압을 인가하여 전기장을 유도한 가운데, X선을 조사하면 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이것은 양단에 유도된 전기장의 영향으로 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 하부기판을 통하여 이미지로 변조된다. 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 조사된 X선을 형광체에서 가시광선으로 전환하고, 이를 Photodiode와 같은 광변환소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말한다. 본 연구에서는 직접방식에서 이용되는 광도전체 중 흡수효율이 높고 Mobility가 뛰어난 CdTe를 선정하여 PVD (Physical vapor deposition)방식으로 300 m의 두께를 목표로 하여 증착을 진행하였다. Chamber의 진공도가 $2.5{\times}10^{-2}$ Torr로 도달 시점부터, Substrate와 Boat에 열을 가하였다. Substrate온도는 $350^{\circ}C$, Boat온도는 $300^{\circ}C$도로 설정하여 11시간 동안 진행하였다. Substrate온도는 $303^{\circ}C$, Boat온도는 $297^{\circ}C$도부터 증착이 시작되어 선형적인 증가세 추이를 나타내어 Substrate 및 Boat온도가 설정 값에 도달 하였을 때, $25{\sim}34.4{\AA}/s$ 증착율을 나타내었다. 하부전극의 물질에 따른 CdTe증착 효율성 평가를 진행한 후, 그에 따른 전기적 특성을 알아보았다. 하부전극의 물질로는 ITO (Indium Tin Oxide), Parylene이 코팅 된 ITO, Au, Ag를 사용하였다. 하부전극의 물질 상단에 Thermal Evaporation System을 사용하여 CdTe를 증착한 후, Cdte 상단에 Au를 증착 시켜 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 증착 결과 ITO와 Ag상단에 증착시킨 CdTe박막은 박리가 되었고, Au와 Parylene이 코팅 된 ITO에는 CdTe박막이 안정적이게 형성이 되었다. 이 두 샘플에 대하여 동일한 조건으로 민감도와 암전류를 측정 시, Parylene이 코팅된 ITO를 하부전극으로 사용한 CdTe박막은 0.1021 pA/$cm^2$의 암전류와 1.027 pC/$cm^2$의 민감도를 나타낸 반면, Au를 하부전극으로 사용한 CdTe박막은 0.0381 pA/$cm^2$의 암전류와 1.214 pC/$cm^2$의 민감도를 나타내어 Parylene이 코팅된 ITO보다 우수한 전기적 특성을 나타내었다. 따라서 Au는 CdTe박막 증착 시, 하부전극 기판으로서 뛰어난 특성을 나타내는 것을 알 수 있었다.

  • PDF

A Study on Bismuth tri-iodide for X-ray direct and digital imagers (직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구)

  • Lee, S.H.;Kim, Y.S.;Kim, Y.B.;Jung, S.H.;Park, J.K.;Jung, W.B.;Jang, M.Y.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.27-31
    • /
    • 2009
  • Now a days, the Medical X-ray equipments has become digitalized from analog type such as film, cassette to CR, DR. And many scientists are still researching and developing the Medical X-ray equipment. In this study, we used the Bismuth tri-iodide to conversion material for digital X-ray equipments and we couldn't get the satisfying result than previous study, but it opened new possibility to cover the disadvantage of a-Se is high voltage aplly and difficultness of make. In this paper, we use $BiI_3$ powder(99.99%) as x-ray conversion material and make films that have thickness of 200um and the film size is $3cm{\times}3cm$. Also, we deposited an ITO(Indium Tin Oxide) electrode as top electrode and bottom electrode using a Magnetron Sputtering System. To evaluate a characteristics of the produced films, an electrical and structural properties are performed. Through a SEM analysis, we confirmed a surface and component part. And to analyze the electrical properties, darkcurrent, sensitivity and SNR(Signal to Noise Ratio) are measured. Darkcurrent is $1.6nA/cm^2$ and sensitivity is $0.629nC/cm^2$ and this study shows that the electrical properties of x-ray conversion material that made by screen printing method are similar to PVD method or better than that. This results suggest that $BiI_3$ is suitable for a replacement of a-Se because of the reduced manufacture processing and improved yield.

  • PDF

Sputtering방식을 이용한 Indium Thin oxide박막의 넓이에 따른 X-ray 검출기 특성 연구

  • Kim, Dae-Guk;Sin, Jeong-Uk;O, Gyeong-Min;Kim, Seong-Heon;Lee, Yeong-Gyu;Jo, Seong-Ho;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.321-322
    • /
    • 2012
  • 의료용 방사선 장비는 초기의 아날로그 방식의 필름 및 카세트에서 진보되어 현재는 디지털 방식의 DR (Digital Radiography)이 널리 사용되며 그에 관한 연구개발이 활발히 진행되고 있다. DR은 크게 간접방식과 직접방식의 두 분류로 나눌 수 있는데, 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 X선을 가시광선으로 전환하고, 이를 Photodiode와 같은 광소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말하며, 직접 방식은 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 고전압을 인가한 형태를 취하고 있는 가운데, X선이 조사되면 일차적으로 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이들은 광도전체 양단의 인가되어 있는 전기장에 의해 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 Active matrix array을 통해 방사선을 검출하는 방식이다. 본 연구에서는 직접방식 X-ray 검출기에서 활용되는 a-Se을 ITO (Indium Thin oxide) glass 상단에 Thermal evaporation증착을 이용하여 두께 $50{\mu}m$, 33 넓이로 증착 시킨 다음, a-Se상단에 Sputtering증착을 이용하여 ITO를 11 cm, 22 cm, $2.7{\times}2.7cm$ 넓이로 증착시켜 상하부의 ITO를 Electrode로 이용하여 직접방식의 X-ray검출기 샘플을 제작하였다. 제작 과정 중 a-Se의 Thermal evaporation증착 시, 저진공 $310^{-3}_{Torr}$, 고진공 $2.210^{-5}_{Torr}$에서 보트의 가열 온도를 두 번의 스텝으로 나누어 증착 시켰다. 첫 번째 스텝 $250^{\circ}C$, 두 번째 스텝은 $260^{\circ}C$의 조건으로 증착하여 보트 내의 a-Se을 남기지 않고 전량을 소모할 수 있었으며, 스텝간의 온도차를 $10^{\circ}C$로 제어하여 균일한 박막을 형성 할 수 있었다. Sputtering증착 시, 저진공 $2.510^{-3}$, 고진공 $310^{-5}$에서 Ar, $O_2$를 사용하여 100 Sec간 플라즈마를 생성시켜 ITO를 증착하였다. 제작된 방사선 각각의 검출기 샘플 양단의 ITO에 500V의 전압을 인가하고, 진단 방사선 범위의 70 kVp, 100 mA, 0.03 sec 조건으로 X-ray를 조사시켜 ITO넓이에 따른 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 측정결과 민감도(Sensitivity)는 X-ray샘플의 두께에 따른 $1V/{\mu}m$ 기준 시, 증착된 ITO의 넓이가 11 cm부터 22 cm, $2.7{\times}2.7cm$까지 각각 $7.610nC/cm^2$, $8.169nC/cm^2$, $6.769nC/cm^2$로 22 cm 넓이의 샘플이 가장 높은 민감도를 나타내었으나, 암전류(Dark current)는 $1.68nA/cm^2$, $3.132nA/cm^2$, $5.117nA/cm^2$로 11 cm 넓이의 샘플이 가장 낮은 값을 나타내었다. 이러한 데이터를 SNR (Signal to Noise Ratio)로 합산 하였을 시 104.359 ($1{\times}1$), 60.376($2{\times}2$), 30.621 ($2.7{\times}2.7$)로 11 cm 샘플이 신호 대 별 가장 우수한 효율을 나타냄을 알 수 있었다. 따라서 ITO박막의 면적이 클수록 민감도는 우수하나 그에 따른 암전류의 증가로 효율이 떨어짐을 검증 할 수 있었으며, 이는 ITO면적이 넓어짐에 따른 저항의 증가로 암전류에 영향을 끼침을 할 수 있었다. 본 연구를 통해 a-Se의 ITO 박막 면적에 따른 전기적 특성을 검증할 수 있었다.

  • PDF