• Title/Summary/Keyword: 필로티

Search Result 73, Processing Time 0.024 seconds

Trial Construction for the Prevention of Fire Spread in Piloti Building (필로티건축물의 화재확산방지를 위한 시범시공)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.87-88
    • /
    • 2019
  • In case of Korea, The Large-scale fire is consistently being such as 2015 Uijeongbu Fire, 2017 Jecheon Fire, 2018 Sejong Hospital Fire. Such a fire has a problem that the fire is spreading upper due to external flame spread. As a countermeasure the fire safety, the study about axial temperature prediction of external flame spread is consistently doing. But in korea, Vertical spandrel is specified as 40cm, and improvement is urgently needed. In this study, a repair material was selected to prevent the fire from spreading to a building where a flammable exterior material was installed and then pilot construction was carried out. Also, fire safety measures for buildings constructed with flammable exterior materials were examined.

  • PDF

A Study on the Air Ventilation System in Apartment Houses as a Health Concept - focused on the air ventilation and pilotis - (공동주택에 건강개념인 통기시스템에 관한 연구 - 공기순환과 필로티를 중심으로 -)

  • Cho, Cheul Hee;Lee, Teuk Koo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.10 no.1
    • /
    • pp.29-38
    • /
    • 2004
  • The purpose of this study is to analyze the air ventilation system in apartment houses focused on the air circulation and pilotis. The air ventilation system is used with the data which were obtained by the environmental health, urban climate, air pollution, ventilation path. The architectural element was pilotis concept connected with piloti ratio, piloti position and piloti type. The summaries of this study were as follows; 1) the well-being apartment concept, 2) the heat island phenomenon, 3) the oxygen density of air, 4) the definition of ventilation path, 5) the pilotis connected with residential environment improvement. In addition, the detailded case study to the air ventilation system in apartment houses be needed.

  • PDF

Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 -)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.86-94
    • /
    • 2018
  • A sports center fire in Jecheon caused 29 deaths and 40 injuries. This study focused only on the structural factors of the building and equipment to investigate the causes of casualties based on the fire investigation results at the sports center. The structural factors of the building and equipment were a piloti-type parking lot, lack of a fire compartment between the piloti-type parking lot and lobby, lack of an installed sprinkler system, lack of an installed fire door in the main stairs on the $1^{st}$ floor, lack of an installed fire water tank on the rooftop, an installed pocket fire door in the main entrance on the $2^{nd}$ floor, poor fire compartments in an EPS space and a pipe pit and on each floor, a leak in the joint of a drain pipe, plywood installed in the hoistway of the freight elevator and interior wall, illegal remodeling of a closed rooftop structure, which cannot discharge smoke and heat, installed styrofoam insulation in the inside of the parking lot ceiling, an installed tempered glass window, which cannot be opened in the ladies bathroom on the $2^{nd}$ floor, and a finished dryvit exterior wall.

The Improvement Direction of Piloti Space for Neighborhood Regeneration of Deteriorated Low-Rise Residential Block (노후 저층주거지 근린재생을 위한 필로티 공간 개선 방향)

  • Yoo, Hae-Yeon;Song, Jun-Yeop;Yang, Ji-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.761-770
    • /
    • 2017
  • The objective of this study is to propose a community facility design for the revitalization of the piloti spaces of deteriorated low-rise residential blocks. For this study, the precedent research and institutional limitations are examined. In addition, this study selected and analyzed a deteriorated low-rise residential block utilizing pilotis. Generally, in this type of residence, 8 to 10 generations live together in multi-family houses and row houses, so it is a type of housing that lacks both public space and parking places. Therefore, we attempted to improve the situation of the communities by making use of the space between the pillars and walls without infringing on the parking places. In addition, we took into consideration the design and arrangement of the piloti by evaluating the inconveniences and needs of the residents through interviews. Specifically, various modules were planned and used to transform the spaces between the pillars of the pillar type piloti structure. This study examined the possibilities offered by various materials and modules, and studied the diverse possibilities that can be offered by changing the modules.

금상 진성찬_ 중앙대-The Showroom on counrtyard

  • Korean Structural Engineers Association
    • 건축구조
    • /
    • v.12 no.4
    • /
    • pp.56-57
    • /
    • 2005
  • 홍대앞의 지상4층, 지하3층의 전시판매시설, 도심지의 부족한 녹지공간을 해소하고자 300평의 대지에 공원을 조성하고 건물은 필로티를 두어 통행과 이동이 용이하도록 하였다. 전체건물은 트러스아치로 이루어진 주 구조체에서 기둥을 내려 각층 슬래브를 받치는 매단구조이며 2개의 도로가 교차되는 지점으로 다수의통행인에 대응하도록 전시실을 케이블로 지지된 캔틸레버로 내밀어 공간을 만들었다.

  • PDF

소음.사생활 침해.보안 문제 해결로 1층의 프리미엄이 오른다

  • Kim, So-Jin
    • 주택과사람들
    • /
    • s.201
    • /
    • pp.80-83
    • /
    • 2007
  • 아파트 1층이 변하고 있다. 최근엔 아파트 지하층에 공동 현관을 마련하거나 1층을 필로티로 설계해 세대원이 소음과 사생활 침해를 받지 않도록 배려하는 것. 1층을 복층형으로 꾸미는 등 한 단계 업그레이드된 공간 연출을 선보이고 있는 분양 아파트를 살펴보았다.

  • PDF

A Study on the Pilotis Design Characteristics in the Highrise Apartment Housing Estates (고충아파트 필로티 디자인 특성 분석에 관한 연구)

  • Lee Jeong-Soo;Song Yong-Ho;Yoo Uoo-Sang
    • Journal of the Korean housing association
    • /
    • v.16 no.6
    • /
    • pp.121-128
    • /
    • 2005
  • This study investigates the design features of pilotis applied to 20 high-rise apartment housings in Korea, completed between January 2000 and August 2005. It analyzes the design characteristics of pilotis on the basis of its spatial configuration and the residents' behavior and suggests the directions of pilotis design in the future. The study finds the followings. 1) The pilotis spaces in foreign apartment housings are used mainly for communal functions such as the passages between buildings for both pedestrians and vehicles. Compared with this public use of pilotis in foreign counterparts, the pilotis spaces in Korean apartment housings are semi-private and have multiple purposes. 2) The pilotis design can be classified on the basis of the spatial configuration elements and the patterns of residents' behavior. The spatial configuration elements consist of ceiling, column, wall, and floor; the residents' behavior can be classified as viewing, resting and playing, driving and parking, and keeping privately-owned objects such as motorcycle and bicycle. 3) Two spatial configuration elements, the wall and the ceiling and two behavioral patterns, 'resting and playing' and 'viewing' are getting more attention by designers in the apartment housings analyzed in this study.

A Study on the Analysis of Fire Risk and Field Survey for FilottI Structures (필로티 구조물의 화재위험성 분석 및 현장조사에 관한 연구)

  • Han, Ji-Woo;Lee, Byeong-heun;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.45-46
    • /
    • 2018
  • The fire at the pilotis parking lot shows the fire propagation paths that are propagated to the ceiling materials and insulation materials and propagated through the external walls. In addition, there is a high risk of fire caused by vehicles with high combustion loads spreading throughout the parking lot. In particular, the omission of the ceiling materials at the parking lot in recent fire cases has contributed to the spread of the fire. In this study, the combustion performance of the ceiling materials between the insulation material and the vehicle is considered to prevent fire from spreading. Based on field research, the type of ceiling material used in the piloti structure showed that SMC ceiling materials have the highest percentage. Combustion performance test (KS F ISO 5660-1) was carried out on the SMC ceiling materials and the AL ceiling materials to review the fire safety of the ceiling finish based on the field investigation. The results of the test showed that the SMC ceiling materials has a THR 28.973[MJ/㎡] and peek HRR 273.93 [kW/㎡], while the AL ceiling material has a THR 0.584[MJ/㎡] and peek HRR 15.215[kW/㎡].

  • PDF

A Study on the Pilotis as a Space of Flow in Le Corbusier's Works (르 꼬르뷔지에 건축에 나타나는 흐름의 공간으로서의 필로티에 관한 연구)

  • Cho, Joo-Hyun;Shin, Buhm-Shik
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.6
    • /
    • pp.194-203
    • /
    • 2012
  • The purpose of this study is to look into a Pilotis as a space of flow in Le Corbusier's works. The first of his principals, "pilotis" shown in "5 principals in new architecture" represents the articulated relationship between architecture and site. The study is based on the flow concept of Pilotis regarding especially its functional, environmental, and visual perspective. Le Corbusier describes his architecture as a circulation representing the modern society. The Pilotis space is often reserved for this circulation while this space is also suggested as a place for the leisure or the garden uninterrupted. So it seems to be meaningful to find out the real usage of the Pilotis space in Le Corbusier's work in order to clarify the relationship between the articulated space and its use proposed. The second question is concerning to the Pilotis space as a space of flow of the light and the air. This issue is not only related to the plastic aspects of the buildings, but also caused from the social, or environmental problematic of those days. Finally, the continuity of the regard is one of the most important characteristics derived from the raised volume by Pilotis.

  • PDF

Correlation of Experimental ana Analytical Inelastic Responses of 1:12 Scale Irregular High-Rise RC Buildings (1:12축소 비정형 고층 RC 건물의 비선형거동에 대한 실험과 해석의 상관성)

  • Ko, Dong-Woo;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.95-104
    • /
    • 2007
  • Three types of high-rise RC building structures having irregularity in the lower two stories were selected as prototypes and were performed nonlinear static analysis by using OpenSees to verify the analysis technique and to investigate the seismic capacity of those buildings. The first one has a symmetrical moment resisting frame (Model 1), the second has an infilled shear wall in the central frame (Model 2), and the third has an infilled shear wall only in one of exterior frames (Model 3). Fiber model, which consists of concrete and reinforcing bar represented from stress-strain relationship, is adapted used for simulate the nonlinearity of members, and MVLEM(Multi vertical linear element model) is used for simulate the behavior of wall. The analytical results are simulate the behavior of piloti stories well, for example, the stiffness and yield farce of piloti stories, the up-lift of wall and the variation of lateral stiffness of column due to the variation of axial forces. Overstrength of Model 2 and Model 3 are about 2 times larger than that of Model 1. The reason of the high oversttrength and ductility of Model 2 and Model 3 is that the conservative design of Model 2 and Model 3, whose beam and column sections are the same as those of Model 1. The ductilities of Model 1 and Model 3 are slightly larger than that of Model 1 and Model 3. Model 1 and Model 3 reached mechanism condition, whereas Model 2 failed to the shear failure of shear wall and the large axial forces in columns due to large overturning moment.