필로티 구조물의 화재위험성 분석 및 현장조사에 관한 연구

A Study on the Analysis of Fire Risk and Field Survey for FilottI Structures

  • 한지우 (호서대학교 소방방재학과) ;
  • 이병흔 (호서대학교 소방방재학과) ;
  • 진승현 (호서대학교 소방방재학과) ;
  • 권영진 (호서대학교 소방방재학과)
  • 발행 : 2018.05.16

초록

The fire at the pilotis parking lot shows the fire propagation paths that are propagated to the ceiling materials and insulation materials and propagated through the external walls. In addition, there is a high risk of fire caused by vehicles with high combustion loads spreading throughout the parking lot. In particular, the omission of the ceiling materials at the parking lot in recent fire cases has contributed to the spread of the fire. In this study, the combustion performance of the ceiling materials between the insulation material and the vehicle is considered to prevent fire from spreading. Based on field research, the type of ceiling material used in the piloti structure showed that SMC ceiling materials have the highest percentage. Combustion performance test (KS F ISO 5660-1) was carried out on the SMC ceiling materials and the AL ceiling materials to review the fire safety of the ceiling finish based on the field investigation. The results of the test showed that the SMC ceiling materials has a THR 28.973[MJ/㎡] and peek HRR 273.93 [kW/㎡], while the AL ceiling material has a THR 0.584[MJ/㎡] and peek HRR 15.215[kW/㎡].

키워드