A Study on Fire and Evacuation simulation analysis for use of Disaster Vulnerable Personal Evacuation Device (재난약자 대피 도움장치 활용을 위한 화재 피난 시뮬레이션 분석 연구)

  • Choi, Doo Chan;Hwang, Hyun Soo;Ko, Min Hyeok;Lee, Si Yu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.824-831
    • /
    • 2020
  • Purpose: In fire case, nursing hospitals are subject to considerable restrictions on evacuation due to the characteristics of occupants and vulnerable elements of buildings, it is important to make evacuation device for vulunerabale person, and need how to intend to increase the efficiency of evacuation by fire and evacuation simulation with helper Method: The smoke characteristics were analyzed by time through fire simulation, finally, the number of helpers according to the day and night was entered, and the evacuation completion time was compared and analyzed using the evacuation simulation. Result: It was found that the evacuation time was shortened by more than 20% when the evacuation assistance device was used for the vulnerable, and the evacuation time was delayed by almost 70% in case of a fire at night compared to the daytime. Conclusion: If the horizontal and vertical evacuation device are effectively utilized in actual fire situations, a strategy appropriate to the situation is deemed necessary. It is expected that evacuation efficiency will increase based on the use of horizontal evacuation evacuation device and vertical evacuation device by developing evacuation manuals

Analysis on Activation Characteristic of Heat Detectors in a Compartment Fire (실내화재에서의 열감지기 동작특성 분석)

  • Ryu, Hocheol
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.598-608
    • /
    • 2014
  • The first operation of alarm system starts at a detector. And the largest effect is produced on the operation of detector by the fire source position and installation position. Nevertheless, the Korean standard for the installation of detector only specifies matters of fire detector installation according to area and height, without consideration of installation position and fire source position. Therefore, this study carried out a fire test in consideration of detector installation position and fire source position (5 places) in order to minimize casualties owing to the fast operation of fire detector when a fire occurred. Considering that it took the longest time for a detector close to a wall to work in the results of this test, it was possible to find that a minimum clearance to the wall was required.

A Study on the Improvement of Survival Rate of the Passengers and Crews according to FDS Analysis (FDS 분석을 통한 승객 및 선원 생존율 향상에 대한 연구)

  • Kim, Won Ouk;Kim, Jong Su;Park, Woe Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.312-317
    • /
    • 2015
  • Seafarers can confront to evacuate from the ship with many reasons such as collision, grounding and fire accident. It believes that evacuation time from ship is very important element in order to increase survival rate in the contingency circumstance, however narrow and complex structure of ship is one of obstacle element against prompt evacuation. Taking into consideration the unique structure of ship compared to the structure of other facilities, speed of fire propagation on board ship is faster than the same size of other type facilities. Therefore, measures to prompt evacuation are required. But it comes with the behavioral constraints of the crews and passengers of the nature of operating in a complex structure with narrow vessels. Therefore, in this study, we propose a formula to be analyzed by theoretical approach and simulation methods to improve the survival rate for the crew and passenger of the ship through the ship's structural modification. We analyzed the temperature rise and visibility which are the most influential effects on the life safety in the event of fire by using a three-dimensional analysis of sight-only program Fire Dynamic Simulator (FDS) as analytical tools.

A Study on the Safety Assessment of Water-based Firefighting Training Center using Fire Dynamics Simulation (FDS를 활용한 수소화 훈련장 안전성 평가에 관한 연구)

  • Doyoeng Park;Junho Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.4
    • /
    • pp.317-323
    • /
    • 2024
  • According to the section A-VI/3 of the International Convention on Standards of Training, Certification and Watchkeeping for Seafarers (STCW), Water-based firefighting training center is mandatory to obtain onboard certificates. This space, being similar to fire situations on ships requires that safety measures be quantified to ensure occupant safety and establish operational standards. For fire safety evaluation, cases were designed based on the presence or absence of smoke control equipment using Pyrosim based on Fire Dynamics Simulation (FDS). Vector analysis was performed to evaluate flow of smoke and heat. Available safe escape time / required safe escpae time (ASET/RSET) analysis was conducted to evaluate safety by comparing the interpreted numerical results through Pathfinder. During safety evaluation of the current operational condition, the appropriateness of the function of each smoke control equipment was numerically and visually indicated. The emergency situation with dust collector stopped was expressed by each evacuation time and safety margin of 111.2 seconds, suggesting that be used as a standard of evacuation time.

A Experimental Study on the Response Characteristics for Fire Detector by Combustibles (가연물에 따른 화재감지기 응답특성에 관한 실험연구)

  • Choi, Moon-Soo;Hong, Sung-Ho;Lee, Sang-Ho;Park, Sang-Tae;Yoo, Song-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.514-517
    • /
    • 2011
  • 화재감지 및 경보시스템의 설계 목표는 화재발생 초기 단계에서 화재징후를 발견, 피난의 개시를 신속하게 통수하는 것이다. 화재감지기는 다양한 건물 및 환경에 설치되기 때문에 주위 온도 및 가연물의 종류 등 환경적 측면을 심층적으로 고려하지 않으면 적절하게 감지하지 못하는 경우가 발생할 수 있다. 즉, 가연물 종류 등을 고려한 설계에 따라 설치된 화재감지기는 화재시 설계치 대로 조기에 화재를 감지하여 화재 예방 및 화재로 인한 피해를 최소화할 수 있는 것이다. 본 논문은 화재시 조기에 화재를 감지기하여 건축물내 인명피난을 목적으로 설치되는 화재감지기의 응답특성을 분석한 연구이다. 화재감지기의 응답특성을 분석하기 위하여 다양한 가연물을 발생시키고 화재감지기 종류별로 설치한 다음 각 화재감지기의 응답특성을 분석하였다. 그 결과 정온식 열감지기는 열방출률이 적은 화재를 조기에 감지하는 것에 적합하지 않은 것으로 나타났다. 광전식 연기감지기는 회색 계통의 목재류 화재성상에서 응답특성이 떨어졌고, 동일한 공간에서 화원의 수평거리와 동작시간이 비례한다고 볼 수 없었다.

  • PDF

Design of Fire Evacuation Guidance System using USN Mesh Routing in High-Rise Buildings (초고층 건물 화재에서 USN 메쉬 라우팅을 이용한 피난유도 시스템 설계)

  • Choi, Yeon-Yi;Joe, In-Whee
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.278-286
    • /
    • 2008
  • When big fire in high rise building and multiplex happens, the needs for high prevention system of disaster are being increased for getting the real-time scene state, quick lifesaver, and safe life security. In this paper the proposed evacuation guidance algorithm which analyzed the feature and danger of fire in high rise buildings, gave simplicity and scalability. Our research shows as fire and disaster occur in high rise buildings we construct sensor networks and sense realtime location information on fire alive people, and the situation information for fire instructed quick and safe escaping route by using mesh routing algorithm scheme relative to exit sign.

Research and Analysis of Elderly Welfare Facilities to Prevent Fire (노인복지시설의 화재방지를 위한 실태조사 및 분석)

  • Jeong, Seong Hui;Shim, Kee Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.186-186
    • /
    • 2011
  • 고령화사회의 도래는 노인의 신체적 정신적 특성과 더불어 장기적인 보살핌과 보호에 대한 요구를 증대시키고 있다. 노인을 입소시켜 급식과 요양서비스를 제공해주는 노인복지시설은 점차 그 시설수가 증가할 것으로 예상되며 재난상황에 대비한 시설의 설계, 운영, 관리, 유지단계에서 화재방지대책에 대한 연구가 필요하다고 본다. 본 연구에서는 노인복지시설의 실태조사를 통해 양로시설에서는 입지유형과 시설규모별 특징을 분석하고, 노인요양시설에서는 시설의 설계방식과 운영방식에 따른 재난상황 발생시 문제점을 분석하였다. 중점 조사항목은 화재발생시 대피장소 확보, 대피시설 및 장비 유무, 인력배치 기준 준수 등 이며 각 시설별 도출한 취약점을 바탕으로 법 제도적 측면에서 개선방안을 제시하였다. 개선이 필요한 항목은 크게 3분류로, 첫째, 설계 및 건축 단계는 노인복지시설 건축허가 기준 재정립, 피난계단, 피난공간 등 기준 보완을 위해 건축 허가시 화재안전성 검토 등이 필요하다. 둘째, 운영 및 유지 단계는 피난 방화(防火)시설 관리 개선, 시설운영자의 책임안전관리, 소방시설 기능유지 강화 등이 필요하다. 셋째, 대응 및 경감 단계는 방재관련 운영관리매뉴얼, 장비 등의 정비 및 보완, 현장대응 및 전문능력 향상, 화재상황전파 시스템 개발 등이 필요할 것으로 분석되었다.

  • PDF

A Study on the Fire Evacuation Assessment Considering Occupied Environment Variation in Existing Buildings (기존 건축물의 사용승인허가 전·후 거주환경을 고려한 화재피난성능평가 연구)

  • Kim, Hak Kyung;Choi, Doo Chan;Kim, In Tae;Kim, Hee Moon;Sim, Hye In
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.105-110
    • /
    • 2016
  • In Korea, fire hazard and risk analysis and response management planning related to existing decrepit buildings, including interior construction and architectural layout revision, due to various occupancy purposes have not been researched or established. Therefore, regulations and technical standards that can manage and reduce fire hazards and risks based on fire hazard analysis and evaluation are required. This study was performed based on a site survey and fire evacuation assessment including performancebased analysis in 3 actual existing buildings to find the life safety issues and provide improvement recommendations.