Analysis on Activation Characteristic of Heat Detectors in a Compartment Fire  

Ryu, Hocheol (Department of Safety Engineering of Chungbuk National University)
Publication Information
Journal of the Society of Disaster Information / v.10, no.4, 2014 , pp. 598-608 More about this Journal
Abstract
The first operation of alarm system starts at a detector. And the largest effect is produced on the operation of detector by the fire source position and installation position. Nevertheless, the Korean standard for the installation of detector only specifies matters of fire detector installation according to area and height, without consideration of installation position and fire source position. Therefore, this study carried out a fire test in consideration of detector installation position and fire source position (5 places) in order to minimize casualties owing to the fast operation of fire detector when a fire occurred. Considering that it took the longest time for a detector close to a wall to work in the results of this test, it was possible to find that a minimum clearance to the wall was required.
Keywords
Spot Type Heat Detector; Operating time; Installation Point; Separation; Distance; Fire source;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Lee, Y.J. (2000). "A Study on the Architectural Proposals to Advance Fire and Egress Safety Performance of High-rise Apartment in Korea." doctor's thesis, graduate school, Dankook University.
2 Choi, M.S. (2005). "A Experimental Study on Responsiveness Characteristics of Fire Detectors and Sprinkler Heads." master's thesis, graduate school, Seoul Industry University.
3 NFPA (2002). SFPE handbook of fire protection engineering, 3rd ed. pp.1-41.
4 ISO 7240-9 (2012). Fire Detection and Alarm Systems-Part 9: Test Fires for Fire Detectors.
5 Jung, K.S., Lee, B.K. (2003). "A Study on Response Characteristics of Ionization Smoke Detector Influenced by Air Stream." Journal of Korean Institute of Fire Science & Engineering, Vol. 17, No. 2, pp. 6-9.   과학기술학회마을
6 NFPA 72 (2007). National Fire Alarm Code.
7 Jung, K.S., Tae,S.H., Lee, B.K. (1993). "Fire Growth of Wood Gribs and Available Safe Egress Time" Journal of KIIS Vol. 8, No. 2, pp. 72-77.
8 Lee, S.H. (2001). "An Estimation of Evacuation Time based on Evacuation Behaviors." master's thesis, The Graduate School of Industrial & Information Technology, Kyonggi University.
9 National Fire Safety Code 203 (2013). Fire Alarm System.
10 NEMA Notification (2012). No.2012-17, Korean Fire Equipment Inspection Standards for Fire Detectors.