• 제목/요약/키워드: 풍소음

검색결과 52건 처리시간 0.025초

방음터널의 풍하중 산정 및 감음성능 예측 (Estimation of Wind Pressure on Soundproof Tunnel and Noise Reduction at Far-field)

  • 임정빈;김영찬;김두훈;조재영;이학은
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.542-547
    • /
    • 2004
  • The objective of this study is 0 estimate wind pressure acting on soundproof tunnel and noise reduction through the tunnel. For the purpose various shape of scale models were prepared and drag forces acting on each models were measured in wind tunnel. And numerical simulation was performed to confirm experimental results. As a result the lowest drag force coefficient of 0.59 was obtained in the case of arch roof shape model. Noise reduction through soundproof tunnel was simulated by using ray tracing method according to various open ratio of its roof area.

  • PDF

선박소음에 관한 연구 (THE STUDY ON THE NOISE IN THE VESSEL)

  • 박중희;김상한
    • 한국수산과학회지
    • /
    • 제8권4호
    • /
    • pp.202-207
    • /
    • 1975
  • 1975년 6월 7일에서 동년 8월 11일까지 풍양호(4,500H. P), 척양호(3,800H. P.), 동방호(3,000 H. P.), 오대산호(2,600 H. P.), 백경호(850 H. P.), 관악산호(1,000 H..P.) 계 6척의 기관실 소음을 주기관의 회전수에 따라 소음압이 변하는 것과 기관실 체격과 총 마력수에 따른 상관관계등을 조사한 결과를 요약하면 다음과 같다. 1. 각 선박의 총 마력수에 따라 기관실 체적이 비례로 커져가고 있으나 소음관계는 같은 종류의 기관(6기통)을 사용하고 있으므로 소음압이 낮아져 가는 경향을 보이는데 관악산초, 척양호, 동방호는 표준 곡선에 비해 소음압이 3dB정도 높은 경향을 보였고 백경호, 풍양호는 4dB 정도 낮은 경향을 보였다. 2. 각 주기관의 최대 회전수(r.p.m.)가 되기 전의 회전수에서 이미 최대의 소음압을 나타내고 있는데 그 회전수의 백분율은 선박에 따라 약간의 차이는 있으나 $67{\~}75{\%}$인 범위에서 최대소음이 되고 있다. 3. 각 기관실의 최대소음압은 $93.5{\~}105dB$의 범위 였고, stern trawl 선박구조를 가진 어획물 처리장은 81 dB 였는데 풍양호만은 72 dB로서 선원 상호간의 대화는 가능하였다. 4. 관악산호를 제외하고는 각 선박식당의 소음압은 $68{\~}75dB$, 싸롱은 $67{\~}72dB$ 선원실은$67{\~}75dB$ 학생실은$67{\~}72dB$였고 갑판의 소음압은 동방호를 제외하고는 $67{\~}72dB$의 범위였다.

  • PDF

거스트 영향이 고려된 랜덤 분포 풍하중에 대한 대형 샌드위치 패널 구조물의 유체-구조 연성해석 (Fluid-structure Interaction Analysis of Large Sandwich Panel Structure for Randomly Distributed Wind Load considering Gust Effects)

  • 박대웅
    • 한국소음진동공학회논문집
    • /
    • 제23권12호
    • /
    • pp.1035-1044
    • /
    • 2013
  • 면내 하중을 지지하는 면재와 면외 하중을 지지하는 심재로 구성되는 샌드위치 패널 구조물은 높은 비강도와 비강성을 가지므로 경량화가 요구되는 대형 구조물에 자주 이용된다. 그러나, 이러한 구조물은 필연적으로 높은 하중에 대하여 유연성의 증가를 일으키게 되므로, 이에 대한 구조 안전성 분석이 이루어져야 한다. 이에 대해 실제 풍하중은 거스트 영향 등을 비롯한 비선형성을 가지는 요소들이 고려되어야 하며, 구조물의 안전성 분석을 위하여 입력 하중에 대해 보다 실제 물리현상에 근접하게 모사되어야 한다. 이에 이 연구에서는 유체-구조 연성해석 기법을 이용하여 대형 등격자-보강 패널 구조물에 대한 구조 안전성 분석이 수행되었다. 입력하중인 풍하중에 대하여 보다 실제적 모사를 위해 불규칙 변동 속도성분인 거스트 영향이 고려된 랜덤분포 풍하중에 대한 유동장을 생성하여 압력-변위 사상을 통하여 연성해석이 수행되었다.

송전철탑의 풍응답 감소를 위한 마찰형 보강기구의 에너지 소산특성 분석 실험 (Experimental Investigation on the Energy Dissipation of Friction-type Reinforcing Members Installed in a Transmission Tower for Wind Response Reduction)

  • 박지훈;문병욱;이성경;민경원
    • 한국소음진동공학회논문집
    • /
    • 제17권7호
    • /
    • pp.649-661
    • /
    • 2007
  • Friction-type reinforcing members(FRM) to enhance the resistance to wind loads of a transmission tower through both stiffness strengthening and damping increase are energy dissipation devices that utilize bending deflection of a tower leg. In this paper, the hysteretic behavior of the transmission tower structure with FRMs was experimentally investigated through cyclic loading tests on a half scale substructure model. Firstly, the variation of friction forces and durability of the FRM depending on the type of friction-inducing materials used in the FRM were examined by performing the cyclic loading tests on the FRM. Secondly, cyclic loading tests of a half-scale two-dimensional substructure model of a transmission tower with FRMs were conducted. Test results show that the FRM, of which desired maximum friction force is easily regulated by adjusting the amplitude of the torque applied to the bolts, have stable hysteretic behaviors and it is found that there exists the optimum torque depending on a design load by investigating the amount of energy dissipation of the FRMs according to the increase of torque.

풍소음 저감용 특수 다중도체 방식의 3차원 전계해석 (3-Dimensional Analysis on Electric Field of Special Conductor Bundle for Reducing Aeolian Noise)

  • 민석원;송기현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.254-258
    • /
    • 2001
  • In this paper, 3-dimensional charge simulation method was developed to analyze electric field distributions of special conductor bundles equipped with spiral rods for reducing aeolian noise. When we applied this method to 765 kV double circuit transmission line, we found calculation error of this method was within a reasonable boundary of 1%.

  • PDF

코로나 케이지 내부에서의 풍소음 저감용 특수 다중도체 방식의 3차원 전계분포해석 II (3-Dimensional Analysis II on Electric Field of Special Conductor Bundle for Reducing Aeolian Noise In Corona Cage)

  • 민석원;송기현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.399-402
    • /
    • 2001
  • In this paper, 3-dimensional charge simulation method was applied to analyze electric field distributions of special conductor bundles equipped with spiral rods for reducing aeolian noise in a corona cage. Comparing electric field distributions of special conductor bundles in 765kV transmission tine with ones in corona case, we decide experimental voltages of special conductor bundles in corona cage.

  • PDF

코로나 케이지 내부에서의 풍소음 저감용 특수 다중도체 방식의 3차원 전계분포해석 (3-Dimensional Analysis on Electric Field of Special Conductor Bundle for Reducing Aeolian Noise In Corona Cage)

  • 민석원;송기현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.359-361
    • /
    • 2001
  • In this paper, 3-dimensional charge simulation method was applied to analyze electric field distributions of special conductor bundles equipped with spiral rods for reducing aeolian noise in a corona cage. We found calculation error of this method was w a reasonable boundary of 0.5%.

  • PDF