• 제목/요약/키워드: 풍력 발전시스템

검색결과 805건 처리시간 0.046초

소형 풍력발전시스템의 출력제어 (Power Control of Small Wind Power System)

  • 김철호;이현채;서영택;조환기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1066_1067
    • /
    • 2009
  • Wind power is one of most promising renewable energy. The output capacity of large wind turbine has been increased for off-shore application. Number of installation of small wind turbine also has been increased for the stand-alone and off-grid application of remote area and recently small wind turbine equipped with lamp on the pole is used for street lamp. Maximum wind energy must be extracted by wind turbine within rated wind speed. Power must be controlled to protect the system such as blade, generator, and power system above the rated wind speed. In this paper, small wind power system of 800W rating for battery charging is implemented and output power control by furling system is verified at wind tunnel test.

  • PDF

가변속 유체토르크 컨버터를 이용한 풍력발전 시스템 연구 (A Study of the Wind Turbine System by Variable Speed Hydraulic Torque Converter)

  • 정경원;김동용;김희규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1114_1115
    • /
    • 2009
  • The wind most of the century, the average wind speed in the coast area 6m/s~8m/s operation as a large wind power generators is not enough to produce. But the generator of proposed wind turbine system is connected to Hydraulic torque converter is the actual development of this usage, the low investment and economic effects appear to be much lower there is. In case of the proposed wind turbine system, is possible to make torque transmission long distance, set up generator somewhere in between the tower or the ground as well as, nacelle weight can be greatly down.

  • PDF

순수 토크 전달을 위한 풍력발전기용 증속기 반력지지 장치 (Pure Torque Reaction System for Wind Tubine Gearbox)

  • 이정훈;박현용;신영호;박종포;박정훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.471-474
    • /
    • 2009
  • Gearbox is used to converter the power with high torque and low speed into the power with low torque and high speed. Gearbox housing should be sustained to prevent rotation of gearbox itself due to the difference between input and out torque. Uneven wind causes the reaction system to have unwanted reactive loads together with predictable pure torque. These unwanted reaction loads often cause the failure of gearbox due to bad gear mesh. In this paper, pure torque reaction system is proposed to prevent the failure of gearbox. Effectiveness and functionality of the proposed reaction system are demonstrated through the numerical analysis.

  • PDF

남해안 어촌 주거시설의 하절기 전력소비 실태 조사 (A Survey on the Electricity Power Consumption in Summer of Residential Areas at Island on South Coast)

  • 구재혁;조형오;황광일
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2011년도 추계학술대회
    • /
    • pp.136-137
    • /
    • 2011
  • 해안 및 도서지역의 전력수요를 파력, 조력, 조류, 해상풍력과 같은 해양발전 시스템을 이용하는 혁신적인 고효율 하이브리드 알고리즘과 기본 모듈을 개발하기 위하여 2011년 하절기 남해안 도서지역 중 1개 섬을 선택하여 섬에 거주하고 있는 주민의 가구에 전력량 측정기를 설치하여 소비전력량 패턴을 확인하였다.

  • PDF

소형풍력발전시스템을 위한 퍼지로직 기반의 가변 스텝 사이즈 MPPT 제어 (Variable Step-Size MPPT Control based on Fuzzy Logic for a Small Wind Power System)

  • 최대근;이교범
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.205-212
    • /
    • 2012
  • This paper proposes the fuzzy logic based variable step-size MPPT (Maximum Power Point Tracking) method for the stability at the steady state and the improvement of the transient response in the wind power system. If the change value of duty ratio is set on stability of the steady state, MPPT control traces to maximum power point slowly. And if the change value is set on improvement of the transient response, the system output oscillates at the maximum power point. By adjusting the step size with fuzzy logic, it can be improved the MPPT response speed and stability at steady state when MPPT control is performed to track the maximum power point. The effectiveness of the proposed method has been verified by simulations and experimental results.

30kw급 수직/수평축 통합형 풍력발전 시스템 개발 (Development of 30kw HAWT/VAWT hybrid wind power system)

  • 신찬;김지언;임종연;송승호;노도환;김동용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.203-206
    • /
    • 2001
  • A 30kw Dual rotor Turbines HAWT/VAWT combined wind turbine system that can drastically enhance the power production capability compared to conventional Single Rotor Turbine HAWT system. The combined system that takes advantage of strong point of both horizontal and vertical Axis wind turbine system developed by a venture firm KOWINTEC of Chonbuk national university. The HAWT/VAWT hybrid system has been successfully field tested and commercial operating since Feb. 12, 2001 in Hae-chang rest park, Bu-an county near the Sae Man-Kum Sea Dike. This paper will briefly describe the field test results performance and a special aerodynamic structure with bevel-planetary gear box of Dual Rotor Wind Turbine system.

  • PDF

계통 연계형 풍력발전 시스템의 고조파 저감 및 무효전력 보상 (Reduction of Harmonics and Compensation of Reactive Power about Wind Power Generation System Connected to Grid)

  • 김영민;황종선;김종만;박현철;송승호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1093-1096
    • /
    • 2002
  • In this paper, a novel multi voltage inverter system is proposed for reductions of harmonics, which can compensate reactive power. At first, we remove capacitor at input side for reactive power compensation. Secondly, by adding DC voltage to the filter capacitor, it can control power factors as lead-phase according to alterations of loads at power reception. Thirdly, if winding and single phase-bridge inverter(auxiliary circuit) is installed to DC power for reduction of harmonic, waveform of output voltages become to 36-steps. Thus, SVC(static var compensator) systems which can reduce harmonics are designed.

  • PDF

풍력발전시스템이 연계된 계통의 과도안정성에 영향을 미치는 요소 (Factors Influencing Transient Stability in Network Connected to Wind Power Generation System)

  • 김세호;오성보;고성민;안재현;이수묵;장시호;이효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.535-536
    • /
    • 2006
  • This paper reports investigation into the factors that influence the transient behavior of the wind power generation system following network fault conditions. It is shown that the critical clearing time(CCT) can be affected by various factors contributed by the host network. Such factors include capacity of wind power, power factor, the length of the interfacing line, etc. This investigation is conducted en a simulated grid-connected wind farm using Digsilent Power Factory.

  • PDF

계통연계형 직렬운전 소형풍력발전시스템의 해석 및 운전방안 연구 (The Analysis and Study on Operation Strategy of Grid-connected Series Small Wind Turbine System)

  • 김창하;구현근;손영득;김장목
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.59-64
    • /
    • 2015
  • This paper proposes an analysis and operation strategy of a grid-connected wind turbine system using a diode rectifier. The currents of generators are the same as that of a small wind turbine system. Therefore, the analysis of generator torque is required as opposed to an analysis of blade speed. In this paper, the appropriate MPPT control method is proposed to control generator torque. Usefulness of the proposed operation strategy is verified by simulations and experiments.

Simulink에서 계통연계 풍력발전시스템의 전압변동 시뮬레이션 (Simulation for Voltage Variations of a Grid-connected Wind Turbine Generation System by Simulink)

  • 안덕근;노경수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권11호
    • /
    • pp.589-595
    • /
    • 2004
  • This paper presents a modeling and simulation of a grid-connected wind turbine generation system with respect to wind variations, starting of large induction motor and three-phase fault in the system, and investigates voltage variations of the system for disturbances. It describes the modeling of the wind turbine system including the drive train model, induction generator model, and grid-interface model on MATLAB/Simulink. The simulation results show the variation of the generator torque, the generator rotor speed, the pitch angle, terminal voltage, system voltage, fault current, and real/reactive power output, etc. Case studies demonstrate that the pitch angle control is carried out to achieve maximum power extraction for wind speed variations, starting of a large induction motor causes a voltage sag due to a large starting current, and a fault on the system influences on the output of the wind turbine generator.