• Title/Summary/Keyword: 폴리에틸렌 삽입물

Search Result 10, Processing Time 0.036 seconds

Reconstruction of Distal Radius Using Ultrahigh Molecular Weight Polyethylene Liner after Excision of Giant Cell Tumor - A Case Report - (원위 요골에 발생한 거대 세포종의 일괄 절제 후 초고분자량 폴리에틸렌 삽입물을 이용한 재건술 - 증례보고 -)

  • Jeon, Dae-Geun;Song, Won-Seok;Oh, Jung-Moon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.1
    • /
    • pp.29-33
    • /
    • 2004
  • A giant cell tumor (GCT) of the distal radius is not common. Curettage with bone cementation is considered as a treatment of choice but, in the case of recurrence, marked cortical disruption, or articular invasion, en bloc excision and reconstruction with proximal fibular bone graft is usual procedure. In reconstruction of en bloc resected distal radius which had recurred GCT after conservative operation, we used the ultrahigh molecular weight polyethylene (UHMWPE) liner with intramedullary rod and bone cement, because the contamination was extent in previous operation and recurrence after fibular bone graft was fearful. This article introduce our new surgical procedure.

  • PDF

Finite Element Analysis for the Contact Stress of Ultra-high Molecular Weight Polyethylene in Total Knee Arthroplasty (전 슬관절 치환 성형술에 사용되는 초고분자량 폴리에틸렌 삽입물의 접촉응력에 관한 유한요소해석)

  • Jo, Cheol-Hyeong;Choe, Jae-Bong;Choe, Gwi-Won;Yun, Gang-Seop;Gang, Seung-Baek
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 1999
  • Because of bone resorption, wear of ultra-high molecular weight polyethylene(UHMWPE) in total knee arthroplasty has been recognized as a major factor in long-term failure of knee implant. The surface damage and the following harmful wear debris of UHMWPE is largely related to contact stress. Most of the previous studies focused on the contact condition only at the articulating surface of UHMWPE. Recently, contact stress at the metal-backing interface has been implicated as one of major factors in UHMWPE wear. Therefore, the purpose of the is study is to investigate the effect of the contact stress for different thickness, conformity friction coefficient, and flexion degree of the UHMWPE component in total knee system, considering the contact conditions at both interfaces. In this study, a two-dimensional non-linear plane strain finite element model was developed. The results showed that the maximum value of von-Mises stress occurred below the articulating surface and the contact stress was lower for the more conforming models. All-polyethylene component showed lower stress distribution than the metal-backed component. With increased friction coefficient on the tibiofemoral contact surface, the maximum shear stress increased about twofold.

  • PDF

Hemiarthroplasty for Osteosarcoma of Proximal Tibia (근위 경골의 골육종에 시행한 반관절성형술)

  • Jeon, Dae-Geun;Cho, Wan-Hyeong;Kim, Jin-Wook-;Koh, Han-Sang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.1
    • /
    • pp.9-14
    • /
    • 2006
  • Purpose: The proximal tibial sarcoma patients, especially in their growing ages have problems of reconstruction. This study is to devise a methodology which can circumvent this limitations. Materials and Methods: Four cases of proximal tibial osteosarcoma underwent hemiarthroplasty. The mean age was 13 years (11~15) with a mean follow-up of 64 months (47~89). The procedure consists of ultrahigh molecular weight polyethylene (UHMWPE) liner as an substitute for the joint surface and this piece was fixed to the remaining tibial bone stock with Ender nail and bone cement. Results: Final functional score was 23.5 (78.3% of control) by MSTS criteria. All the cases showed stable joint without pain. Hemiarthroplasty related complications were absent. By saving the femoral physis, expected leg length discrepancy could be minimized by this procedure. Conclusions: Hemiarthroplasty of proximal tibia can be an option in pediatric sarcoma patients.

  • PDF

Research on Ultrasound System and Measurement Technology for Mechanical Defect Monitoring of Human-inserted Artificial Medical Devices (인체 삽입형 인공 의료 기구물 기계적 결함 모니터링을 위한 초음파 시스템 및 계측 기술 연구)

  • Youn, Sangyeon;Lee, Moonhwan;Hwang, Jae Youn
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.470-473
    • /
    • 2021
  • In this study, we developed the biometric ultrasound transducer, residual thickness measurement algorithm and optimized ultrasound operation methods to diagnose precise conditions of implanted medical prosthetic material inserted during total hip artificial joint replacement. In detail, ultrasound transducers having 8 MHz and 20 MHz center frequencies with similar sensitivity and bandwidth were fabricated to measure various thicknesses of commercial polyethylene-based artificial hip liners, resulting in a comparative analysis of signal-to-noise ratio and axial resolution to conduct an optimization study of ultrasound operations in vivo.

  • PDF

The Failure of Polyethylene Lock of MUTARS Distal Femur Tumor Endoprostheses: A Case Report (원위 대퇴골 종양 금속 대치물(MUTARS$^{(R)}$)의 폴리에틸렌 잠김(LOCK)부 파손: 증례 보고)

  • Jeong, Won-Ju;Park, Il-Hyung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.19 no.2
    • /
    • pp.74-77
    • /
    • 2013
  • The guidelines for the treatment of massive bone defects caused by bone resection due to tumors have changed from amputation to limb salvaging surgery. Limb salvaging surgery using endoprotheses is a well-established procedure. However, Aseptic loosening, infection, and mechanical defect remain significant problems. Among them, we experienced the case with a breakage of polyethylene lock of MUTARS$^{(R)}$ distal femur tumor Endoprostheses.

Otoplasty with High Density Polyethylene Implant(MEDPOR®) (잠복이에서 고밀도 폴리에틸렌 삽입물(MEDPOR®)을 이용한 귀성형술)

  • Lee, Keun-Cheol;Kwon, Yong-Seok;Heo, Jung;Moon, Ju-Bong;Kim, Seok-Kwun
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.167-173
    • /
    • 2009
  • Purpose: The key points of treatment of cryptotia are the elevation of invaginated ear helix and the correction of deformed cartilage. Prevention of stabilized cartilage contouring from returning to the previous state is also important. The authors carried otoplasty by modified Onizuka's method or Ohmori's method that conchal cartilage graft or high density polyethylene implant(MEDPOR$^{(R)}$) graft served as fixation after spreading posterior aspect of adhered antihelix and a splint for prevention of recurrence of cartilage deformities. The aim of this study is to reveal the availability of the high density polyethylene implant(MEDPOR$^{(R)}$) graft for the correction of cryptotia. Methods: We have repaired 17 cryptotic deformities using cartilage graft from cavum of concha(12 cases) or high density polyethylene implant(5 cases) for correction of deformed cartilage. We investigate the operative time, complications, and satisfaction of postoperative ear shape on both autogenous cartilage graft group and high density polyethylene implant graft group. Results: There was 1 case of reinvagination on autogenous cartilage graft group. Implant exposure was occurred on high density polyethylene implant graft group, as 1 case. These were statistically no differences between autogenous cartilage graft group and high density polyethylene implant graft group to the satisfaction of ear shape. Conclusion: High density polyethylene implant(MEDPOR$^{(R)}$) present an alternative to autogenous material as they allow of fibrovascular ingrowth, leading to stability of the implant and decreased infection rates. The correction of deformed cartilage by using the high density polyethylene implant(MEDPOR$^{(R)}$) is a good option for the treatment of cryptotia.

Improved Activity Estimation using Combined Scatter and Attenuation Correction in SPECT (단일광자방출단층촬영 영상에서 산란 및 감쇠 보정에 위한 절대방사능 측정)

  • Lee, Jeong-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.382-390
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the accuracy of radioactivity quantitation in Tc-99m SPECT by using combined scatter and attenuation correction. Materials and Methods: A cylindrical phantom which simulates tumors (T) and normal tissue (B) was filled with varying activity ratios of Tc-99m. We acquired emission scans of the phantom using a three-headed SPECT system (Trionix, Inc.) with two energy windows (photopeak window: $126{\sim}154keV$ and scatter window: $101{\sim}123keV$). We performed the scatter correction with dual-energy window subtraction method (k=0.4) and Chang attenuation correction. Three sets of SPECT images were reconstructed using combined scatter and attenuation correction (SC+AC), attenuation correction (AC) and without any correction (NONE). We compared T/B ratio, image contrast [(T-B)/(T+B)] and absolute radioactivity with true values. Results: SC+AC images had the highest mean values of T/B ratios. Image contrast was 0.92 in SC+AC, which was close to the true value of 1, and higher than AC (0.77) or NONE (0.80). Errors of true activity by SPECT images ranged from 1 to 11% for SC+AC, $22{\sim}47%$ for AC, and $2{\sim}16%$ for NONE in a phantom which was located 2.4cm from the phantom surface. In a phantom located 10.0cm from the surface, SC+AC underestimated by 24%, NONE 40%. However, AC overestimated by 10%. Conclusion: We conclude that accurate SPECT activity quantitation of Tc-99m distribution can be achieved by dual window scatter correction combind with attenuation correction.

  • PDF

Clinical Results of Medial Unicompartmental Knee Arthroplasty in Elderly Patients Older than 70 Years of Age (70세 이상의 고령 환자에서 시행한 내측 슬관절 단일구획치환술의 임상 결과)

  • Kim, Kyung Tae;Lee, Song;Kim, Jin Hak;Lee, Ho Young;Kim, Myung Jin
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • Purpose: To evaluate the long-term clinical results and survivorship of unicompartmental knee arthroplasty (UKA) in elderly patients older than 70 years by analyzing cases that have been implanted for >10 years ago. Materials and Methods: The long-term follow-up results were evaluated in 39 patients (46 cases) who underwent medial UKA from March 2002 to February 2004. The mean age of the patients at the time of surgery was 74.0 years, and the preoperative diagnosis was degenerative arthritis of the knee in all cases. Results: Of the 46 cases, reoperation occurred due to the complications in four cases. In 22 cases without 14 cases of death and six cases of follow-up loss, follow-up more than 10 years was possible. The mean Knee Society knee and function scores improved significantly from 53.0 and 52.5 points pre-operatively to 89.4 and 80.9 points at the last follow-up, respectively (p<0.001). The mean range of motion of the knee recovered to 132.5°, and the mean tibiofemoral angle changed to 5.9° of valgus at the last follow-up. Complications following the UKA occurred in four cases; the most prevalent complication was mobile bearing dislocation (n=2). One case of failure occurred due to aseptic loosening and degenerative arthritis of the lateral compartment, respectively. The cumulative survival rate of the implants was 95.0% at 10 years and 85.7% at 15 years. Of the 40 cases, excluding six cases of follow-up loss, 36 cases (90.0%) could be used without reoperation until death or at the last follow-up after surgery. Conclusion: These results showed the outstanding functions of the knee and satisfactory long-term survivorship after UKA. Therefore, UKA could be a useful method for the treatment of osteoarthritis of the knee in elderly patients older than 70 years of age.

Derivation of the Effective Energy Calculation Formula of the X-ray Beam Generated by the CT Simulator (CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식 유도)

  • Kim, Jong-Eon;Lee, Sang-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.869-875
    • /
    • 2021
  • The purpose of this study is to derive a formula for calculating the effective energy of an X-ray beam generated by a CT simulator. Under 90, 120, and 140 kVp X-ray beams, the CT number calibration insert part of the AAPM CT performance phantom was scanned 5 times with a CT simulator. The CT numbers of polyethylene, polystyrene, water, nylon, polycarbonate, and acrylic were measured for each CT slice image. The average value of CT number measured under a single tube voltage and the linear attenuation coefficients corresponding to each photon energy calculated from the data of the National Institute of Standards and Technology were linearly fitted. Among the obtained correlation coefficients, the photon energy having the maximum value was determined as the effective energy. In this way, the effective energy of the X-ray beam generated at each tube voltage was determined. By linearly fitting the determined effective energies(y) and tube voltages(x), y=0.33026x+30.80263 as an effective energy calculation formula was induced.

A Study on Chloride Threshold Level of Blended Cement Mortar Using Polarization Resistance Method (분극저항 측정기법을 이용한 혼합 시멘트 모르타르의 임계 염화물 농도에 대한 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu;Ann, Ki-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.245-253
    • /
    • 2009
  • The importance of chloride ions in the corrosion of steel in concrete has led to the concept for chloride threshold level (CTL). The CTL can be defined as the content of chlorides at the steel depth that is necessary to sustain local passive film breakdown and hence initiate the corrosion process. Despite the importance of the CTL, due to the uncertainty determining the actual limits in various environments for chloride-induced corrosion, conservative values such as 0.4% by weight of cement or 1.2 kg in 1 $m^3$ concrete have been used in predicting the corrosion-free service life of reinforced concrete structures. The paper studies the CTL for blended cement concrete by comparing the resistance of cementitious binder to the onset of chloride-induced corrosion of steel. Mortar specimens were cast with centrally located steel rebar of 10 mm in diameter using cementitious mortars with ordinary Portland cement (OPC) and mixed mortars replaced with 30% pulverized fuel ash (PFA), 60% ground granulated blast furnace slag (GGBS) and 10% silica fume (SF), respectively, at 0.4 of a free W/B ratio. Chlorides were admixed in mixing water ranging 0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binder(Based on $C1^-$). Specimens were curd 28 days at the room temperature, wrapped in polyethylene film to avoid leaching out of chloride and hydroxyl ions. Then the corrosion rate was measured using the polarization resistance method and the order of CTL for binder was determined. Thus, CTL of OPC, 60%GGBS, 30%PFA and 10%SF were determined by 1.6%, 0.45%, 0.8% and 2.15%, respectively.