잠복이에서 고밀도 폴리에틸렌 삽입물(MEDPOR®)을 이용한 귀성형술

Otoplasty with High Density Polyethylene Implant(MEDPOR®)

  • 이근철 (동아대학교 의과대학 성형외과학교실) ;
  • 권용석 (동아대학교 의과대학 성형외과학교실) ;
  • 허정 (동아대학교 의과대학 성형외과학교실) ;
  • 문주봉 (동아대학교 의과대학 성형외과학교실) ;
  • 김석권 (동아대학교 의과대학 성형외과학교실)
  • Lee, Keun-Cheol (Department of Plastic & Reconstructive Surgery, College of Medicine. Dong-A University) ;
  • Kwon, Yong-Seok (Department of Plastic & Reconstructive Surgery, College of Medicine. Dong-A University) ;
  • Heo, Jung (Department of Plastic & Reconstructive Surgery, College of Medicine. Dong-A University) ;
  • Moon, Ju-Bong (Department of Plastic & Reconstructive Surgery, College of Medicine. Dong-A University) ;
  • Kim, Seok-Kwun (Department of Plastic & Reconstructive Surgery, College of Medicine. Dong-A University)
  • 발행 : 2009.03.15

초록

Purpose: The key points of treatment of cryptotia are the elevation of invaginated ear helix and the correction of deformed cartilage. Prevention of stabilized cartilage contouring from returning to the previous state is also important. The authors carried otoplasty by modified Onizuka's method or Ohmori's method that conchal cartilage graft or high density polyethylene implant(MEDPOR$^{(R)}$) graft served as fixation after spreading posterior aspect of adhered antihelix and a splint for prevention of recurrence of cartilage deformities. The aim of this study is to reveal the availability of the high density polyethylene implant(MEDPOR$^{(R)}$) graft for the correction of cryptotia. Methods: We have repaired 17 cryptotic deformities using cartilage graft from cavum of concha(12 cases) or high density polyethylene implant(5 cases) for correction of deformed cartilage. We investigate the operative time, complications, and satisfaction of postoperative ear shape on both autogenous cartilage graft group and high density polyethylene implant graft group. Results: There was 1 case of reinvagination on autogenous cartilage graft group. Implant exposure was occurred on high density polyethylene implant graft group, as 1 case. These were statistically no differences between autogenous cartilage graft group and high density polyethylene implant graft group to the satisfaction of ear shape. Conclusion: High density polyethylene implant(MEDPOR$^{(R)}$) present an alternative to autogenous material as they allow of fibrovascular ingrowth, leading to stability of the implant and decreased infection rates. The correction of deformed cartilage by using the high density polyethylene implant(MEDPOR$^{(R)}$) is a good option for the treatment of cryptotia.

키워드

참고문헌

  1. Ohmori S, Matsumoto K: Treatment of cryptotia using Teflon string. Plast Reconstr Surg 49: 33, 1972 https://doi.org/10.1097/00006534-197201000-00006
  2. Torikai T, Ando S, Yoshida T, Asano T, Matsumoto Y, Yasuse M: Anatomy of the auricular muscles and its application to surgical treatment of cryptotia. Jpn J Plast Reconstr Surg 25: 46, 1982
  3. Gosserez M, Piers JH: Congenital invagination of the external ear. Ann Chir Plast 4: 143, 1959
  4. Pollock WJ: Technique for correction of cryptotia. Plast Reconstr Surg 44: 501, 1969 https://doi.org/10.1097/00006534-196944050-00024
  5. Nishioka I, Naito M, Fujimoto M, Yosida Y, Kanetaki I, Ogura Y: Correction of cryptotia with a prosthesis utiltzing the force of restitution. Jpn J Plast Reconstr Surg 26: 266, 1983
  6. Onizuka T, Tokunaga S, Yamada K: A method for repair of cryptotia. Plast Reconstr Surg 62: 734, 1978 https://doi.org/10.1097/00006534-197811000-00013
  7. Cowan RJ: Cryptotia. Plast Reconstr Surg 27
  8. Washio H: Cryptotia: pathology and repair. Plast Reconstr Surg 52: 648, 1973 https://doi.org/10.1097/00006534-197312000-00008