• Title/Summary/Keyword: 포탈 영상

Search Result 38, Processing Time 0.024 seconds

Monte Carlo simulation of the electronic portal imaging device using GATE

  • Chung, Yong-Hyun;Baek, Cheol-Ha;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.11-16
    • /
    • 2007
  • In this study, the potential of a newly developed simulation toolkit, GATE for the simulation of electronic portal imaging devices (EPID) in radiation therapy was evaluated by characterizing the performance of the metal plate/phosphor screen detector for EPID. We compared the performances of the GATE simulator against MCNP4B code and experimental data obtained with the EPID system in order to validate its use for radiation therapy.

  • PDF

Creative Project and Reward Based Crowdfunding:Determinants of Success (창의적 프로젝트와 후원형 크라우드펀딩: 성공요인)

  • Chun, Hesuk
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.5
    • /
    • pp.560-569
    • /
    • 2015
  • Crowd funding is the method of raising money for a project, companies from a large group of people via the Internet, in return for future products or equity. Kickstarter is the largest and most successful crowdfunding site where creative projects raise reward based funding. Drawing on dataset of 80,267 projects with combined funding over $1.3b from 8.1m people, this paper suggest that backer select project based on their preference on the project, instead profitability of the project. It suggests that well-established platform and big size of network increases the chance of success of the project due to a ripple effect and blockbuster effects. Clear communication about the project's idea and goal is highly correlated with success. Regular communication on the project site, such as by constant progress updates, helps the success of the project. Equity-based crowdfunding is emerging as an innovative means of raising capital for businesses, so it has been receiving a lot of attention and expectation from the government and the market. The findings of this paper and others will help to get some understanding and insight into equity-based crowdfunding. However, Kickstarter differs from equity-based crowdfunding in the goals of the backers. Kickstarter's backers are not investors, they are contributors. To understand equity-based crowdfunding, the subject will need further study.

The analysis of an Animation Effectiveness in the Web (In case of Education portal site) (웹 상에서 애니메이션 효과분석계 (교육 포탈사이트를 중심으로))

  • Shin Soon-Ho
    • Journal of Digital Contents Society
    • /
    • v.2 no.2
    • /
    • pp.199-208
    • /
    • 2001
  • The industries of culture contents is the trend to enforce the power of National competitions in the world economy knowledge foundation which tries to exchange a labor industry to the knowledge business. The spread of internet is the apparently turning point to be devide the world economy into the industrial society and the digital society. Also the communication with internet has been recognized as it is not any more newly means of communication in Korea. Net value which is a multinational internet survey corporation clarified that Korea was the most nation in the world by the result of its research in the rate of using internet. This research look into the characteristic of the media and type of the animation in internet, also analysis a need of user and a degree of convenience of using internet in the web of education site. This study is designed to study the evaluation criteria of web interface with visual perception and to seek its development in relation to the quality of visual perception in case of web animation.

  • PDF

The Comparative evaluation of cultural contents preference for active seniors' enjoyment (액티브시니어의 문화향유 콘텐츠 선호도 비교평가)

  • Kim, Woo-Seop;Shin, Young-Seok;Shin, I-Su;Kim, Kyu-Ho;Jung, Duk-Young
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.12 no.1
    • /
    • pp.20-28
    • /
    • 2018
  • In this research, for the smooth cultural life of seniors, we recruit 92 smart seniors (male: 22, female: 70) and survey their preferred content sub-genre. The survey is mainly based on the two devices (PC, Smartphone) to be used. As a result of the study, there was a little difference in preference on the web pages between both devices, the video contents showed the similar preference, regardless of the device. Also, sub-genres surveyed show higher correlations with similar sub-genres in other content genres. So, If the result of this study is reflected in the development of cultural contents and the composition of content pages, it will be helpful for senior to enjoy the improved cultural life by lowering entry barriers accessing digital media contents.

Comparison of the Efficacy of 2D Dosimetry Systems in the Pre-treatment Verification of IMRT (세기조절방사선치료의 환자별 정도관리를 위한 2차원적 선량계의 유용성 평가)

  • Hong, Chae-Seon;Lim, Jong-Soo;Ju, Sang-Gyu;Shin, Eun-Hyuk;Han, Young-Yih;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.91-102
    • /
    • 2009
  • Purpose: To compare the accuracy and efficacy of EDR2 film, a 2D ionization chamber array (MatriXX) and an amorphous silicon electronic portal imaging device (EPID) in the pre-treatment QA of IMRT. Materials and Methods: Fluence patterns, shaped as a wedge with 10 steps (segments) by a multi-leaf collimator (MLC), of reference and test IMRT fields were measured using EDR2 film, the MatriXX, and EPID. Test fields were designed to simulate leaf positioning errors. The absolute dose at a point in each step of the reference fields was measured in a water phantom with an ionization chamber and was compared to the dose obtained with the use of EDR2 film, the MatriXX and EPID. For qualitative analysis, all measured fluence patterns of both reference and test fields were compared with calculated dose maps from a radiation treatment planning system (Pinnacle, Philips, USA) using profiles and $\gamma$ evaluation with 3%/3 mm and 2%/2 mm criteria. By measurement of the time to perform QA, we compared the workload of EDR2 film, the MatriXX and EPID. Results: The percent absolute dose difference between the measured and ionization chamber dose was within 1% for the EPID, 2% for the MatriXX and 3% for EDR2 film. The percentage of pixels with $\gamma$%>1 for the 3%/3 mm and 2%/2 mm criteria was within 2% for use of both EDR2 film and the EPID. However, differences for the use of the MatriXX were seen with a maximum difference as great as 5.94% with the 2%/2 mm criteria. For the test fields, EDR2 film and EPID could detect leaf-positioning errors on the order of -3 mm and -2 mm, respectively. However it was difficult to differentiate leaf-positioning errors with the MatriXX due to its poor resolution. The approximate time to perform QA was 110 minutes for the use of EDR2 film, 80 minutes for the use of the MatriXX and approximately 55 minutes for the use of the EPID. Conclusion: This study has evaluated the accuracy and efficacy of EDR2 film, the MatriXX and EPID in the pre-treatment verification of IMRT. EDR2 film and the EPID showed better performance for accuracy, while the use of the MatriXX significantly reduced measurement and analysis times. We propose practical and useful methods to establish an effective QA system in a clinical environment.

A study on the establishment of Korean-Chinese language education service platform using AR/VR technology (AR/VR 기술을 활용한 한-중 어학교육 서비스 플랫폼 구축방안 연구)

  • Chun, Keung;Yoo, Gab Sang
    • Journal of Digital Convergence
    • /
    • v.17 no.9
    • /
    • pp.23-30
    • /
    • 2019
  • The development of content for language education using AR/VR technology is a necessary task to be pursued in line with commercialization of 5G. Research on service platform for systematic management and service is currently being carried out by global companies competitively, The unique language education service model for unique areas of culture has the right to pursue R & D jointly with Korea and China. In this study, we applied the developed "Korean language education service platform for Chinese people based on e-learning" to improve the acceptance of AR/VR contents and applied AR/VR technology to video-based language education contents. And to present a new paradigm of language education. Contents development is to develop AR-based vocabulary learning services, develop experiential learning contents for VR-based step-by-step situations, and gradually develop contents to enable beginner / intermediate / advanced language education services. The service platform enables management of learning management and learning contents, and complies with metadata attributes to complete a platform capable of accommodating large capacity AR/VR contents. In the future, systematic research will be carried out in order to develop as a portal for educational services through development of various contents using mixed reality technology.

Comparative evaluation for leaf position accuracy according to gantry angle variation in MLC quality assurance using electronic portal imaging device(EPID) and GafChromic EBT3 film (전자포탈영상장치(EPID)와 GafChromic EBT3 film을 이용한 다엽콜리메이터 정도관리 시 갠트리 각도 변화에 따른 엽의 위치 정확성 비교 평가)

  • Yang, Myung Sic;Park, Ju Kyeong;Lee, Seung Hun;Lee, Sun Young;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.83-91
    • /
    • 2017
  • Objectives: The purpose of this study was to evaluate the error of the leaf position accuracy of the MLC due to the gravity effect according to the gantry angle by using picket fence test using EPID and GafChromic EBT3 film. Materials and Methods: A 5 cm solid phantom was placed on the table and the SAD was set to 100 cm. The EBT3 film was placed exactly over the solid phantom and covered a 1.5 cm solid phantom and the picket fence test was performed. The EPID was measured under the same conditions as the EBT3 film at SID 100 cm. The gantry angles were measured at $0^{\circ}$, $90^{\circ}$, $180^{\circ}$ and $270^{\circ}$ in order to evaluate the position of the MLC according to the gantry angle. For the geometric evaluation of the MLC, the leaf position accuracy of the MLC was analyzed using the analysis program. Results: In case of EPID, when the gantry angle was changed to $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$, the difference of the position errors of the leaves was 0.18 mm, 0.31 mm, 0.20 mm, 0.26 mm on the average and the maximum values of the errors were respectively 0.44 mm, 0.54 mm, 0.34 mm, 0.44 mm. In case of EBT3 film, when the gantry angle was changed to $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$, the difference of the position errors of the leaves was 0.19 mm, 0.21 mm, 0.19 mm, 0.31 mm on the average and the maximum values of the errors were respectively 0.35 mm, 0.45 mm, 0.36 mm, 0.48 mm. Conclusion: In this study, we analyzed the position error of the leaf of the MLC according to the gantry angle, and confirmed the position error of the leaf by gravity effect. As a result of comparing the leaf position accuracy using EPID and EBT3 film according to the variation of gantry angle, a larger error occurred in the error analysis method using EPID than that of EBT3 film. Therefore, in the case of IMRT based on MLC, as well as verification of accurate dosimetry should be conducted, it is considered that the quality control and verification for the precise operation of the MLC will be needed. and it is necessary to compare and verify the method of analysis.

  • PDF

Effectiveness Assessment on Jaw-Tracking in Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Esophageal Cancer (식도암 세기조절방사선치료와 용적세기조절회전치료에 대한 Jaw-Tracking의 유용성 평가)

  • Oh, Hyeon Taek;Yoo, Soon Mi;Jeon, Soo Dong;Kim, Min Su;Song, Heung Kwon;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.33-41
    • /
    • 2019
  • Purpose : To evaluate the effectiveness of Jaw-tracking(JT) technique in Intensity-modulated radiation therapy(IMRT) and Volumetric-modulated arc therapy(VMAT) for radiation therapy of esophageal cancer by analyzing volume dose of perimetrical normal organs along with the low-dose volume regions. Materials and Method: A total of 27 patients were selected who received radiation therapy for esophageal cancer with using $VitalBeam^{TM}$(Varian Medical System, U.S.A) in our hospital. Using Eclipse system(Ver. 13.6 Varian, U.S.A), radiation treatment planning was set up with Jaw-tracking technique(JT) and Non-Jaw-tracking technique(NJT), and was conducted for the patients with T-shaped Planning target volume(PTV), including Supraclavicular lymph nodes(SCL). PTV was classified into whether celiac area was included or not to identify the influence on the radiation field. To compare the treatment plans, Organ at risk(OAR) was defined to bilateral lung, heart, and spinal cord and evaluated for Conformity index(CI) and Homogeneity index(HI). Portal dosimetry was performed to verify a clinical application using Electronic portal imaging device(EPID) and Gamma analysis was performed with establishing thresholds of radiation field as a parameter, with various range of 0 %, 5 %, and 10 %. Results: All treatment plans were established on gamma pass rates of 95 % with 3 mm/3 % criteria. For a threshold of 10 %, both JT and NJT passed with rate of more than 95 % and both gamma passing rate decreased more than 1 % in IMRT as the low dose threshold decreased to 5 % and 0 %. For the case of JT in IMRT on PTV without celiac area, $V_5$ and $V_{10}$ of both lung showed a decrease by respectively 8.5 % and 5.3 % in average and up to 14.7 %. A $D_{mean}$ decreased by $72.3{\pm}51cGy$, while there was an increase in radiation dose reduction in PTV including celiac area. A $D_{mean}$ of heart decreased by $68.9{\pm}38.5cGy$ and that of spinal cord decreased by $39.7{\pm}30cGy$. For the case of JT in VMAT, $V_5$ decreased by 2.5 % in average in lungs, and also a little amount in heart and spinal cord. Radiation dose reduction of JT showed an increase when PTV includes celiac area in VMAT. Conclusion: In the radiation treatment planning for esophageal cancer, IMRT showed a significant decrease in $V_5$, and $V_{10}$ of both lungs when applying JT, and dose reduction was greater when the irradiated area in low-dose field is larger. Therefore, IMRT is more advantageous in applying JT than VMAT for radiation therapy of esophageal cancer and can protect the normal organs from MLC leakage and transmitted doses in low-dose field.