• Title/Summary/Keyword: 평균체류시간

Search Result 172, Processing Time 0.031 seconds

Analysis and Improvement Measures on the Status of the Installation and Operation of Facilities for Recycling Food Waste into Compost (음식물쓰레기 퇴비화시설의 설치 및 운영 현황분석 및 개선방안)

  • Ryu, Ji-Young;Kong, Kyu-Sik;Shin, Dae-Yewn;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.95-111
    • /
    • 2004
  • This research sought to determine the status of the installation and operation of composting facilities of domestic public resource-making facilities and come up with corresponding improvement measures. The composting facilities were the most extensively installed of related facilities with over a 0.5 ton treated volume per day. The monthly and yearly carry-in volume of food waste were found to stand at 1,101.7 tons per day and 930.9 tons per day, thus falling short of the average planned volume of 1,270.9 tons. Many composting facilities, which were installed in areas for which factory registration were not approved, did not get approvals. Composting facilities underwent operation stoppage mainly due to faulty fermentation and crushing equipment. Mainly metals contained in food waste caused faults to the crushing equipment, thus requiring a facility designing against faults and corrosion. The initial water content was found to stand at 50-60%, thus complying with the requirement. However, since the composting food waste had an appropriate mixture of sawdust, food waste, and returned compost, it should meet the initial conditions. For fermentation facilities, the duration time for fermentation was 15 days, and post-fermentation tanks required 21 days of duration time, thus establishing the minimum criteria. However, some facilities did not meet the requirements, taking more time in decomposition, thus suggesting a need to determine the duration time according to facilities. In composting food waste, microorganism-based thermal oxidizer-operated fermentation tanks should be used to ensure an economic operation. On the contrary, 14 out of 25 survey targets heated fermentation tanks in any form. These thermal facilities contain the growth of bacteria, lowering chemical reaction in composting; thus composting facilities should be basically designed to use microorganism-based thermal oxidizers in drying water. An average daily volume of food waste and supplementary materials that was injected in producing compost was 22.8 tons. This volume produced 7.3 tons of compost per day, decreasing 68%. Properties of produced compost were analyzed by its color, absence or presence of remaining decomposition heat, and smell, to assess the quality. As a result, the composting process was not properly installed nor operated in about 50% of composting facilities. Compost should be produced to be soil-friendly.

  • PDF

Estimates of Flushing Time in a Bay using the SCS Curve Number Method (SCS 유출곡선지수법(流出曲線指數法)을 이용한 만내(灣內) 담수(淡水) 교체시간(交替時間)의 추정(推定))

  • Kim, Jong Hwa;Chang, Sun Duck;Song, Hyun Ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.6
    • /
    • pp.1453-1463
    • /
    • 1994
  • The SCS Curve Number(CN) method has become widely accepted as a procedure of estimating stormflow volumes for design and natural events in small watersheds. The applicability of this method for calculating the flushing time was evaluated as compared with the net volume transport(NVT) method in Masan Bay, Korea. It is shown that the flushing time using the CN method ranged from 10.9 to 15.3 days under the well mixed condition, that the time using the NVT method was 13.9 days averaged over 6 days of field data. These results were revealed that two methods calculated the approximate times as shown above. The relationships between the run-off, Qr, and the flushing time, t, are expressed as the following forms. $t_1=228.79Q_r^{-0.9996}$ in case of well mixed condition, (1) $t_2=131.06Q_r^{-1.0}$ in case of two layered model. (2) Those empirical expressions are represented that the relationships between Q and t are nonlinear as those as Bumpus obtained in Boston Inner Harbour. Therefore, the CN method will permit calculation of the flushing time for any given bay to be unexpected as water balance under the condition of short-time (0.5 day) data, instead of NVT method based on the long-time (at least 3 days over) data.

  • PDF

Effect of Air Temperature Changes on Water Temperature and Hysteresis Phenomenon in Lake Paldang (기온 변화에 따른 팔당호 수온 영향 및 이력현상)

  • Yu, Soonju;Im, Jongkwon;Lee, Bomi
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.5
    • /
    • pp.323-337
    • /
    • 2020
  • Long-term continuous data were used to investigate changes in air and water temperature and temperature hysteresis at Lake Paldang, the largest source of drinking water in South Korea. Based on the temperatures at Yangpyeong, near Lake Paldang, using a seasonal Mann-Kendall test, the rate of change of increase in temperature over the last 27 years (0.060℃/yr, 1993-2019) was higher than that of during 47 years (0.048℃/yr, 1973-2019). The air and water temperatures in Lake Paldang and its influent rivers had a high correlation (R > 0.9, p < 0.005); however, the water temperature increased at rate slower than the river water temperature, and the water temperature decreased slowly as the air temperature fell. The depth-averaged water temperature also changed more slowly than the surface water of the lake both when the air temperature was high and when it was low. This is likely because the lake has a larger area and a longer heat retention time than rivers, resulting in a greater hysteresis of water temperature at lake.

A Study on Foodservice Operation for a Menu Strategy in Expressway Rest Areas (고속도로 휴게소의 메뉴전략을 위한 외식서비스실태연구)

  • Bai, Young-Hee
    • Culinary science and hospitality research
    • /
    • v.18 no.3
    • /
    • pp.1-17
    • /
    • 2012
  • This study was planned for an empirical review of foodservice operation in expressway rest areas for a menu strategy targeting staff and customers. The results were as follows. Main foodservice category included 10-30 items of Korean dishes. The needs for having branded foodservice menu in rest areas were high in fusion/fast foods, snack/ready-made and beverages. Employment of professional cooks in rest areas was low (10-30%), and the most important factor was 'taste' when cooking Korean foods. Foreigners preferred fusion/fast foods and snack/ready-made foods to Korean food, beverages and Japanese/Chinese foods, and most of the foreigners ordered food with 'no question'(55.5%) or 'some questions'(34.8%). Rest area staff prepared some photos/pictures of foods (80-100%) for menu comprehension, but the accuracy of menu transcription was very low. Customers used a rest area once or twice, stayed for 10-20 min(43.6%)/20-30 min(38.6%), visited by car(77.7%) to relax and use toilets(61.6%) on average. Favorite food and snacks were Korean(32.7%) and ready made/snacks(33.0%), and they spent 5,000-10,000 won(51.3%), 3,000-5,000 won(25.8%) on them. Customer satisfaction with rest areas was 'average' regardless of gender, age, education levels and jobs. With this analysis, we should prepare an efficient menu strategy for customer satisfaction and plans for analyzing problems along with alternatives.

  • PDF

Changes of Seasonal and Vertical Water Quality in Soyang and Paldang River-reservoir System, Korea (소양호와 팔당호 수질의 수직 및 계절적 변화)

  • Kim, Jong-Min;Park, Jun-Dae;Noh, Hye-Ran;Han, Myung-Soo
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.1 s.97
    • /
    • pp.10-20
    • /
    • 2002
  • Changes of seasonal and vertical water quality was analyzed with physico-chemical data from Soyang and Paldang river-reservoir system in Korea during the 1996 to 1998. In Soyang river-reservoir system, the water column was well stratified, which narrow epilimnion layer of 5 to 10 m depth in spring to summer enlarged gradually about 40 m depth in fall as going to times. In contrast, metalimnion layer tended to be narrow during the same period. Water temperature of hypolimnion was maintained about $5^{\circ}C$ continuously throughout the year. DO of the epilimnion layer was supersaturated from spring to summer, however, it was decreased to 75% at the epilimnion layer and $45{\sim}50%$ at the hypolimnion layer at the late fall. The lowest conductivity of below $50\;{\mu}S/cm$ was observed at the metalimnion layer during thesummer to fall. In Paldang river-reservoir system, the water column wag well mixed layer throughout the year, although water temperature was changed seasonally from $5^{\circ}C$ in February to $28^{\circ}C$ in July. Water temperature between upper and lower layer was different about $5^{\circ}C$ from late spring (May) to early fall (September). DO was over and less saturated in upper and lower layer during the early summer to early fall, respectively. Conductivity was decreased to $90\;{\mu}S/cm$ in lower layer of below $4{\sim}5\;m$ depth during the late spring to early fall and that of upper layer of above 10 m depth decreased to about $100\;{\mu}S/cm$ during the late fall (November) and early spring (March). Retention time of Soyang river-reservoir system was much longer than that of Paldang river-reservoir system. Chlorophyll a, T-N and T-P concentration in Paldang river-reservoir system were higher than that of Soyang river-reservoir system by a factor of 2.7, 1.2 and 2.6, respectively. Algal blooming was deeply affected by the nutrients than the retention time.

Hydrodynamics and Liquid Flow Characteristics in an Internal Circulation Airlift Reactor using a Single Nozzle (단일노즐을 사용한 내부순환 공기리프트 반응기에서 수력학과 액체의 흐름특성)

  • Kim, Jong-Chul;Jang, Sea-Il;Son, Min-Il;Kim, Tae-Ok
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.816-821
    • /
    • 1997
  • The hydrodynamics and the liquid flow characteristics were investigated in an internal circulation airlift reactor with a single nozzle as a gas distributor. In an air-water system, the gas holdup in the individual flow zone and the impulse-response curve of tracer were measured at various gas velocities and reactor heights. Experimental results showed that for the higher gas velocity(>about 8 cm/s), the flow behavior of bubbles in the riser was turbulent flow due to strong bubble coalescences and the axial height of dispersion zone of large bubbles having uniform sizes in the downcomer was decreased with increasing gas velocity. And mean gas holdups in the individual flow zone and the reactor were increased with increasing gas velocities and were decreased with increasing heights of the top section of the reactor and it was decreased with increasing the height of the top section and gas velocity. Flow characteristics of liquid in the riser and the downcomer was tend to access to plug flow and the overall flow behavior of liquid was mainly varied with the size of the top section which it was assumed to be perfect mixing zone. In these conditions, liquid circulation velocities were increased with increasing gas velocities and they were higher than those by using other gas distributors.

  • PDF

Gas and Liquid Flow Characteristics in an Internal Circulation Airlift Reactor using a Single Nozzle -Effects of Flow Zone Sizes- (단일노즐을 사용한 내부순환 공기리프트 반응기에서 기체 및 액체의 유동특성 - 유동지역의 크기영향 -)

  • Jang, Sea-Il;Kim, Jong-Chul;Jang, Young-Joon;Son, Min-Il;Kim, Tae-Ok
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.901-906
    • /
    • 1998
  • Gas and liquid flow characteristics were investigated in an internal circulation airlift reactor using a single nozzle for a gas distributor. In three reactors with different diameters of the downcomer and heights of the riser, the gas holdup in the individual flow zone and the impulseresponse curve of tracer for an air-water system were measured for various gas velocities and reactor heights. Experimental results showed that the flow behavior of bubbles in the riser was the slug flow due to strong coalescences of bubbles and that the bubble flow pattern in the downcomer was the transition bubble flow for the smaller diameter of the downcomer, however, it was the homogeneous bubble flow for the larger one. And mean gas holdups in the individual flow zone and the reactor were greatly increased with decreasing the diameter of the downcomer for the equal ratio of height of the top section to that of the riser. Also, the mixing time was much effected by the height of the top section of reactor and for the equal ratio of height of top section to that of the riser, it was increased with increasing the diameter of the downcomer and the height of the riser. Flow characteristics of liquid were mainly varied with the bubble flow pattern in the downcomer and the size of the top section of reactor. And circulation velocities of liquid in the riser were increased with increasing gas velocities and the size of the top section of reactor, and for the equal ratio of height of top section to that of the riser, they were increased with increasing the diameter of the downcomer and the height of the riser.

  • PDF

Methane Fermentation of Pit in Pond System for Ecological Treatment and Recycling of Animal Excreta (생태적 축산폐수 처리 및 재활용 연못시스템의 Pit 메탄발효)

  • Yang, Hong-Mo
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.2
    • /
    • pp.191-195
    • /
    • 1999
  • An integrated wastewater treatment pond system is developed for treatment and recycling of excreta from dairy cattle. It is composed of three ponds in series. A pit with a capacity of $10m^3$, 2-day hydraulic residence time, and overflow velocity of $1.5m^3m^{-2}day^{-1}$ is located internally in primary pond. It is designed for efficient sludge sedimentation and effective methane fermentation. It receives $5m^3/day$ of diluted cattle excreta by the water used for clearing stalls. A submerged gays collector for the recovery of methane is installed on the top of the pit. The average BOD_5 concentration of influent is 398.7mg/l. That of the effluent from primary pond is 49.2mg/l. About 88% of BOD_5 are removed in primary pond. It is assumed that about 60% of the influent BOD_5 is removed in the pit and that almost all of the carbon of the removed BOD_5 in the pit is converted to methane and carbon dioxide. Methane fermentation of the pit is well established at $16^{\circ}C$. This phenomena results from temperature stability, complete anaerobic condition, and neutral pH of the pit. Gas from the collector is almost 90% methane, less than 9% nitrogen, and less than 1% carbon dioxide. Thus a purified methane is produced, which can be used as energy source.

  • PDF

Effects of Alkalinity on the Nitrification Capability of Nonwoven Fabric Filter Bioreactor (부직포 여과막 생물반응조에서 알칼리도가 질산화 성능에 미치는 영향)

  • Bae, Min-Su;Ahn, Yoon-Chan;Jang, Myung-Bae;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.783-792
    • /
    • 2007
  • To investigate the effects of alkalinity on the nitrification capability of the nonwoven fabric filter bioreactor(NFBR), an experiment was performed for 641 days at a hydraulic retention time of approximately 11 hours by changing the influent concentration of $NH_3-N$ from 54 mg/L to 1,400 mg/L and alkalinity from 43 mg/L to 10,480 mg/L. The MLSS concentration reduced from an initial value of 2,650 mg/L down to 830 mg/L, then increased up to 8,340 mg/L. Though the volumetric loading rate varied in a range of $0.120\sim3.130$ kg $NH_3-N/m^3-day$, the F/M ratio showed a narrow range of $0.067\sim0.414$ kg $NH_3-N/kg$ MLSS-day. The average nitrification efficiency at each experimental stage resulted in the range of $35.2\sim100%$, and the maximum nitrification rate was 2.970 kg $N/m^3-day$ or 0.489 g N/g MLVSS-day. The nitrifiers' fraction of the MLVSS increased up to 100% from an initial value of 7.1% and the biofilm formed on the nonwoven fabric filter showed a very low nitrifiers' fraction of mere 2.2%. The growth yield of the MLSS and the alkalinity consumption rate were computed to be 0.117 g VSS/g N removed and 7.08 g alkalinity/g $NO_x^--N$ produced, respectively. Results of the research suggest that NFBR could be an adequate process for nitrification of wastewaters with high ammonia concentrations.

Development of Influent Controlled Membrane Bioreactor for Biological Nutrient Removal on Municipal Wastewater (하수 고도처리를 위한 유로변경형 MBR공정의 개발)

  • Park, Jong-Bu;Shin, Kyung-Sook;Hur, Hyung-Woo;Kang, Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.485-491
    • /
    • 2011
  • This study was performed to investigate the characteristics of nutrient removal of municipal wastewater in membrane bioreactor system. Membrane bioreactor consists of four reactors such as two intermittently anaerobic tanks, the oxic tank and the sludge solubilizaion tank with an internal recycle. The hydraulic retention time (HRT) and flux were 6.5 hours and $20.4L/m^2{\cdot}hr$ (LMH), respectively. The removal efficiency of $COD_{Cr}$, SS, TN and TP were 94.0%, 99.3%, 99.9%, 69.9%, and 66.9%, respectively. The estimated true biomass yield, specific denitrification rate (SDNR), specific nitrification rate (SNR), specific phosphorus release rate (SPRR) and specific phosphorus uptake rate (SPUR) were 0.34 kgVSS/kgBOD d, $0.067mgNO_3-N/mgVSS{\cdot}d$, $0.028mgNH_4-N/mgVSS{\cdot}d$, 16.0 mgP/gVSS d and 2.1 mgP/gVSS d, respectively. The contents of nitrogen and phosphorus of biomass were 8.9% and 3.5% on an average.