• Title/Summary/Keyword: 평균막

Search Result 554, Processing Time 0.035 seconds

Process Development of Wastewater Containing Silicon Fine Particles by Ultrafiltration for Water Reuse -III. Permeation Characteristics of Pilot Scale Hollow Fiber Membrane Modules- (한외여과에 의한 Si 미립자 함유폐수 재이용 공정개발(III) -Pilot-Scale 중공사막 모듈에 의한 투과 특성)

  • 전재홍;함용규;이석기;박영태;남석태;최호상
    • Membrane Journal
    • /
    • v.9 no.3
    • /
    • pp.185-192
    • /
    • 1999
  • The ultrafiltration characteristics of wafer processing wastewater produced from semicon¬ductor industry was investigated for wastewater reuse. Using the pilot-scale ultrafiltration system con¬taining poly sulfone hollow fiber membranes (MWCO : 10,000, 20,000, 30,(00), the membrane performance, such as flux, rejection rate and concentration factor for flux was examined. The SDhs, turbidity, electrical conductivity and concentration of Si particles were measured, and the possibility of permeate reuse was validated from the experimental results. It was shown that the flux was recovered by the sweeping with air and water effectively. The permeate flux of 30,000 MWCO membrane was about 5 times higher than that of 10,000 and 20,000 MWCO membranes. The concentration of Si particle in the saw wastewater was analyzed 3.8-5.6 mg/$\ell$ and that of Si particle in the permeate was analyzed less than 0.2${\mu}g$/$\ell$. This means the rejection of silicon particle was over 96%.

  • PDF

The Optomotor Response of Crusian Carp and Goldfish in Accordance with the Colors of the Wall and the Stripes of the Visual Screen (시각막의 바탕과 줄무늬의 색상에 따른 붕어와 금붕어의 시각운동 반응)

  • 장충식
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.17-22
    • /
    • 1984
  • The author carried out an experiment to find on the optomotor response of crusian carp, Carassius carassius and goldfish, Carassius auratus in accordance with the colors of the wall and the stripes labeled on the revolving visual screen. The results are as follows; 1. The optomotor response rate of crusian carp was 80% or more in case of B-Y, R-Bl and W-Bl pair of colors, and 50% or less in case of Bl-B, B-Bl, R-W, R-Y, W-Y and Y-W pair. 2. The optomotor response rate of goldfish was 80% or more in all except B-Bl, W-R and W-Y pair. 3. Mean round number of crusian carp was 7.5-9.5 revolutions in case of W-Bl, Y-Bl, W-B and Y-B pair, and 1.8-3.9 revolutions in case of Bl-B, Bl-Y, B-Bl, B-R, R-All and Y-W pair for 3 minutes. 4. Mean rounded number of goldfish was only 4.1-4.9 revolutions in case of W-Bl, W-B and Y-B pair for 3 minutes.

  • PDF

Optical Properties of Plasmons in a GaAs/AlxGa1-xAs Multiple Quantum Well Under Electric and Magnetic Fields (전기장과 자기장하의 GaAs/AlxGa1-xAs 다중 양자 우물 내 플라즈몬의 광학적 속성)

  • Ahn, Hyung Soo;Lee, Sang Chil;Kim, Suck Whan
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1183-1191
    • /
    • 2018
  • The plasmon behaviors in a superlattice of $GaAs/Al_xGa_{1-x}As$ multiple quantum wells with a half-parabolic confining potential due to different dielectric interfaces are studied under magnetic and electric fields perpendicular and parallel to the superlattice axis by using a previously published theoretical framework. From the density-density correlation functions by considering the intrasubband and the inter-subband transitions under the random phase approximation, we calculate the dispersion energies of the surface and the bulk states as functions of the composition of the multiple quantum well structure and of the magnetic field strength and the average electric field strength over the quantum well. The Raman intensities for various magnetic field strengths and average electric field strengths over the quantum well are also obtained as a function of the energy of the incoming light for these states.

Operative Treatment of Congenitally Corrected Transposition of the Great Arteries(CCTGA) (교정형 대혈관 전위증의 수술적 치료)

  • 이정렬;조광리;김용진;노준량;서결필
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.621-627
    • /
    • 1999
  • Background: Sixty five cases with congenitally corrected transposition of the great arteries (CCTGA) indicated for biventricular repair were operated on between 1984 and september 1998. Comparison between the results of the conventional(classic) connection(LV-PA) and the anatomic repair was done. Material and Method: Retrospective review was carried out based on the medical records of the patients. Operative procedures, complications and the long-term results accoding to the combining anomalies were analysed. Result: Mean age was 5.5$\pm$4.8 years(range, 2 months to 18years). Thirty nine were male and 26 were female. Situs solitus {S,L,L} was in 53 and situs inversus{I,D,D} in 12. There was no left ventricular outflow tract obstruction(LVOTO) in 13(20%) cases. The LVOTO was resulted from pulmonary stenosis(PS) in 26(40%)patients and from pulmonary atresia(PA) in 26(40%) patients. Twenty-five(38.5%) patients had tricuspid valve regurgitation(TR) greater than the mild degree that was present preoperatively. Twenty two patients previously underwent 24 systemic- pulmonary shunts previously. In the 13 patients without LVOTO, 7 simple closure of VSD or ASD, 3 tricuspid valve replacements(TVR), and 3 anatomic corrections(3 double switch operations: 1 Senning+ Rastelli, 1 Senning+REV-type, and 1 Senning+Arterial switch opera tion) were performed. As to the 26 patients with CCTGA+VSD or ASD+LVOTO(PS), 24 classic repairs and 2 double switch operations(1 Senning+Rastelli, 1 Mustard+REV-type) were done. In the 26 cases with CCTGA+VSD+LVOTO(PA), 19 classic repairs(18 Rastelli, 1 REV-type), and 7 double switch operations(7 Senning+Rastelli) were done. The degree of tricuspid regurgitation increased during the follow-up periods from 1.3$\pm$1.4 to 2.2$\pm$1.0 in the classic repair group(p<0.05), but not in the double switch group. Two patients had complete AV block preoperatively, and additional 7(10.8%) had newly developed complete AV block after the operation. Other complications were recurrent LVOTO(10), thromboembolism(4), persistent chest tube drainage over 2 weeks(4), chylothorax(3), bleeding(3), acute renal failure(2), and mediastinitis(2). Mean follow-up was 54$\pm$49 months(0-177 months). Thirteen patients died after the operation(operative mortality rate: 20.0%(13/65)), and there were 3 additional deaths during the follow up period(overall mortality: 24.6%(16/65)). The operative mortality in patients underwent anatomic repair was 33.3%(4/12). The actuarial survival rates at 1, 5, and 10 years were 75.0$\pm$5.6%, 75.0$\pm$5.6%, and 69.2$\pm$7.6%. Common causes of death were low cardiac output syndrome(8) and heart failure from TR(5). Conclusion: Although our study could not demonstrate the superiority of each classic or anatomic repair, we found that the anatomic repair has a merit of preventing the deterioration of tricuspid valve regurgitations. Meticulous selection of the patients and longer follow-up terms are mandatory to establish the selective advantages of both strategies.

  • PDF

Dependence of the Diamond Coating Adhesion on the Microstructure of WC-Co Substrates (WC-Co계 미세조직에 따른 CVD 다이아몬드 코팅막의 접착력 변화)

  • Lee, Dong-Beum;Chae, Ki-Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.728-734
    • /
    • 2004
  • The effect of microstructure of WC-Co substrates which have different WC grain sizes from submicron to 5 $\mu$m on the diamond-substrate adhesion strength was investigated. The substrates were pre-treated by two methods : chemical etching with Murakami's solution and subsequently with $H_2SO_4$, and thermal heat-treatment. The adhesion strength was estimated by degree of peeling after Rockwell indentation. Diamond films of 20 $\mu$m thickness deposited on the heat-treated substrates showed an excellent adhesion strength at the load of 100 kg, which ascribed to the large and elongated WC grains. However, the cutting edge of insert was deformed after heat treatment and the surface morphology of heat treated substrate strongly affected on the surface roughness of the deposited diamond films. On the contrary, the diamond film of 10 $\mu$m in thickness on the chemically etched substrates of average WC grain size over 2 $\mu$m showed good adhesion strength enough not to peel-off under a load of 60 kg. Especially, the substrate of average WC grain size over 5 $\mu$m exhibited much improved reliability of adhesion comparing with the substrate of average grain size under 2 $\mu$m. No substrate deformation was observed in this case after the chemical etching, which is more advantageous and more practical in terms of precious machining than the heat treatment case.

Characteristics of Transparent Conductive Tin Oxide Thin Films on PET Substrate Prepared by ECR-MOCVD (PET 기판상에 ECR 화학증착법에 의해 제조된 SnO2 투명도전막의 특성)

  • Kim, Yun Seok;Jeon, Bup Ju;Ju, Jeh Beck;Sohn, Tae Won;Lee, Joong Kee
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.85-91
    • /
    • 2005
  • $SnO_2$ films were prepared at room temperature under a $(CH_3)_4Sn-H_2-O_2$ atmosphere in order to obtain transparent conductive polymer by using ECR-MOCVD (Electron Cyclotron resonance -Metal Organic Chemical Vapor Deposition) system. The electrical properties of the films were investigated as function of process parameters such as deposition time, microwave power, magnetic current power, magnet/showering/substrate distance and working pressure. An increase in microwave power and magnetic current power brought on $SnO_2$ film formation with low electric resistivity. On the other hand, the effects of process parameters described above on optical properties were insignificant in the range of our experimental scope. The transmittance and reflectance of the films prepared by the ECR-MOCVD exhibited their average values of 93-98% at wave length range of 380-780 nm and 0.1-0.5%, respectively. The grain size of the $SnO_2$ films that are also insensitive with the process parameters were in the range of 20-50 nm. On the basis of experimental data obtained in the present study, electrical resistivity of $7.5{\times}10^{-3}ohm{\cdot}cm$, transmittance of 93%, and reflectance of 0.2% can be taken as optimum values.

Investigation of aluminum-induced crystallization of amorphous silicon and crystal properties of the silicon film for polycrystalline silicon solar cell fabrication (다결정 실리콘 태양전지 제조를 위한 비정절 실리콘의 알루미늄 유도 결정화 공정 및 결정특성 연구)

  • Jeong, Hye-Jeong;Lee, Jong-Ho;Boo, Seong-Jae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.6
    • /
    • pp.254-261
    • /
    • 2010
  • Polycrystalline silicon (pc-Si) films are fabricated and characterized for application to pc-Si thin film solar cells as a seed layer. The amorphous silicon films are crystallized by the aluminum-induced layer exchange (ALILE) process with a structure of glass/Al/$Al_2O_3$/a-Si using various thicknesses of $Al_2O_3$ layers. In order to investigate the effects of the oxide layer on the crystallization of the amorphous silicon films, such as the crystalline film detects and the crystal grain size, the $Al_2O_3$ layer thickness arc varied from native oxide to 50 nm. As the results, the defects of the poly crystalline films are increased with the increase of $Al_2O_3$ layer thickness, whereas the grain size and crystallinity are decreased. In this experiments, obtained the average pc-Si sub-grain size was about $10\;{\mu}m$ at relatively thin $Al_2O_3$ layer thickness (${\leq}$ 16 nm). The preferential orientation of pc-Si sub-grain was <111>.

Treatment of Garbage Leachate with Two-phase Anaerobic Digestion Coupled with Ultra Filtration (막결합형 2상 혐기성 소화 공정을 이용한 음식물 탈리액 처리)

  • Lee, Eun-Young;Kim, Hyung-Kuk;Giang, Luu Thi Thuy;Bae, Jae-Ho;Bae, Young-Shin;Won, Jong-Choul;Lee, Jae-Hoon;Park, Seung-Kyun;Cho, Yong-Wan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.997-1006
    • /
    • 2009
  • Organic removal efficiency and methane production rate, a feasibility of power generation from biogas, and the optimum conditions for membrane operation were evaluated for the pilot scale (5 tons/day) two-phase anaerobic digestion coupled with ultra filtration (TPADUF) system fed with garbage leachate. The TPADUF system is consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. When garbage leachate with 150 g/L of TCOD was fed to the TPADUF up to organic loading rate (OLR) of 11.1 g COD/L/d, the effluent TCOD was lower than 6 g/L and the average removal efficiencies of TCOD and SCOD were higher than 95%. The methane composition of the gas was 65%, and the methane yield was 39 $m^3/m^3$ garbage leachatefed, 260 $m^3$/tons $COD_{added}$, or 270 $m^3$/tons $COD_{removed}$, even there was some gas leak. The power production per consumed gas was 0.96 kWh/$m^3$ gas or 1.49 kWh/$m^3$ methane. This lower power production efficiency mainly due to the small capacity of gas engine (15 kW class). The membrane was operated at the average flux of 10 L/$m^2$/hr. When the flux decreased, washing with water and chemical (NaOCl) was conducted to restore the flux. In the TPADUF system, optimum pH could be maintained without alkali addition by recycling the membrane concentrate or mixed liquor of the methanogenic digester to the acidogenic reactor. Also, partial production of methane in the acidogenic reactor had a positive effect on lowering the OLR of the methanogenic reactor.

Mitral Valve Repair for Active and Healed Endocarditis (급성 혹은 치유된 심내막염 환자에서의 승모판막성형술)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Sae;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Kang, Chang-Hyun;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kim, Wook-Sung;Lee, Young-Tak;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.820-827
    • /
    • 2003
  • Background: Mitral valve repair rather than replacement for mitral regurgitation (MR) offers a number of well-accepted benefits. However, the surgical results of repair for mitral valve endocarditis remain largely unknown. Material and Method: Fourteen patients who underwent mitral valve repair for MR caused by mitral valve endocarditis from April 1995 through October 2001 were reviewed retrospectively. There were 9 male patients and mean age was 32$\pm$10 years. Four patients had previous embolism and 2 had active infections. The grade of MR were III in 6 patients and IV in 8. Operatively, mitral annuloplasty was performed in 12 patients and various valvuloplasty techniques were applied in all patients. One patient had immediate valve replacement due to residual MR after weaning of cardiopulmonary bypass. Result: There was no early operative death. Early postoperative transthoracic echocardiography revealed no or grade I of MR and no or mild mitral stenosis in 13 patients. After the mean follow-up of 36 months, there was no late death, and no or grade I of MR in 11 patients (84.6%) and no or mild mitral stenosis in 12 patients (92.3%). Reoperation required in one patient (7.1%). The cumulative freedom from recurrent MR and valve-related reoperation at 5 years were 91$\pm$9% and 75$\pm$22%, respectively. Conclusion: This study suggests that mitral valve repair for mitral regurgitation caused by endocarditis offers good early and intermediate survival and functional improvement without reinfection, and it is an attractive alternative to valve replacement in selective patients with bacterial endocariditis.

Intermediate-term Result of Tricuspid Annuloplasty for Tricuspid Regurgitation Associated with Congenital Heart Disease in Adult (성인 선천성 심기형에 동반된 삼첨판막 폐쇄부전의 판막륜 성형술 후 중기성적)

  • Yun, Tae-Jin;Kim, Sang-Hwa;Lee, Jun-Wan;Park, Jeong-Jun;Song, Hyun;Lee, Jae-Won;Seo, Dong-Man;Song, Meong-Gun;Song, Jong-Min;Kang, Duck-Hyun;Song, Jae-Kwan;Jang, Wan-Sook;Kim, Young-Hwue;Ko, Jae-Kon;Park, In-Sook
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.136-141
    • /
    • 2003
  • We assessed the intermediate-term result of tricuspid annuloplasty (TAP) for tricuspid valve regurgitation (TR) associated with congenital heart disease in adults. Risk factors for residual TR were also analysed. Material and Method: From August 1989 to June 2001, seventy three adult patients, 51 females and 22 males, underwent TAP for TR associated with various congenital heart disease. Their age ranged from 46 years to 73 years (mean:43). Associated heart anomalies were atrial septal defect (55), ventricular septal defect (6), partial anomalous pulmonary venous return (4) and others (8). Preoperative and post-operative TR velocities were 3.25 m/sec and 2.56 m/sec respectively, and the types of TAP were De Vega in 43, Kay in 18 and Ring annuloplasty in 12. Postoperative follow-up duration was 2,347 patient-month (mean: 32.6 months), and 134 two-dimensional echocardiographic examinations were done during this period. Residual TR greater than III/IV was considered as TAP failure. Result: TAP failure was observed in 7 patients (9.6%), and one patient among them underwent tricuspid valve replacement. Risk factors for TAP failure were diagnosis other than atrial septal defect (p=0.001), preoperative (p=0.038) and postoperative (p=0.028) high TR velocity. There was no statistical significance in terms of TAP methods. Conclusion: Careful evaluation of valve morphology and aggressive surgical intervention are mandatory for the repair of TR with preoperative or residual RV pressure overload.