• Title/Summary/Keyword: 펄스생성

Search Result 301, Processing Time 0.035 seconds

Mobile phone payment system using a light signal (휴대폰의 광원을 이용한 디지털 카드 시스템)

  • Hu, Moon-Heang;Shin, Moon-Sun;Ryu, Kuen-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1237-1244
    • /
    • 2009
  • In this paper, we proposed a mobile phone payment system using light signal containing payment related information. The digicard system we proposed creates virtual mobile card such as credit numbers and the created information is loaded in mobile phone. The virtual card information should be changed to pulse signal by light signal devices of mobile phone and the specific digicard system reader is able to read light signal. In recent years, a mobile phone payment system has been developed in order to provide user's convenience. But the mobile phone payment system has problems such as the production costs and complex and large size. In order to solve the aforementioned problems, we proposed mobile phone payment system being implemented by updating software without additional hardware modules. Therefore it is possible to apply the proposed digicard system to all kinds of mobile phone. Also encryption module is implemented to solve the problem of the security and privacy. According to an aspect of the present invention, there is provided a mobile phone payment system using a light signal containing payment-related information, comprising: a mobile phone; a photo receiver: and a control server.

A Design of LLC Resonant Controller IC in 0.35 um 2P3M BCD Process (0.35 um 2P3M BCD 공정을 이용한 LLC 공진 제어 IC 설계)

  • Cho, Hoo-Hyun;Hong, Seong-Wha;Han, Dae-Hoon;Cheon, Jeong-In;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.5
    • /
    • pp.71-79
    • /
    • 2010
  • This paper presents a design of a LLC resonant controller IC. LLC resonant controller IC controls the voltage of the 2nd side by adjusting frequency the input frequency of the external resonant circuit. The clock generator is integrated to provide the pulse to the resonant circuit and its frequency is controlled by the external resistor. Also, the frequency of the VCO is adjusted by the feedback voltage. The protection circuits such as UVLO(Under Voltage Lock Out), brown out, fault detector are implemented for the reliable and stable operation. The HVG, and LVG drivers can provide the high current and voltage to the IGBT. The designed LLC resonant controller IC is fabricated with the 0.35 um 2P3M BCD process. The overall die size is $1400um{\times}1450um$, and supply voltage is 5V, 15V.

Design of the Noise Margin Improved High Voltage Gate Driver IC for 300W Resonant Half-Bridge Converter (잡음 내성이 향상된 300W 공진형 하프-브리지 컨버터용 고전압 구동 IC 설계)

  • Song, Ki-Nam;Park, Hyun-Il;Lee, Yong-An;Kim, Hyoung-Woo;Kim, Ki-Hyun;Seo, Kil-Soo;Han, Seok-Bung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.7-14
    • /
    • 2008
  • In this paper, we designed the HVIC(High Voltage Gate Driver IC) which has improved noise immunity characteristics and high driving capability. Operating frequency and input voltage range of the designed HVIC is up to 500kHz and 650V, respectively. Noise protection and schmitt trigger circuit is included in the high-side level shifter of designed IC which has very high dv/dt noise immunity characteristic(up to 50V/ns). And also, rower dissipation of high-side level shifter with designed short-pulse generation circuit decreased more that 40% compare with conventional circuit. In addition, designed HVIC includes protection and UVLO circuit to prevent cross-conduction of power switch and sense power supply voltage of driving section, respectively. Protection and UVLO circuit can improve the stability of the designed HVIC. Spectre and Pspice circuit simulator were used to verify the operating characteristics of the designed HVIC.

회야강 하구 주변의 지형변화(진하 해수욕장을 중심으로)

  • Park, Sang-Gil;Choe, Seon-Ho;Cheon, Su-Gyeong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1990.07a
    • /
    • pp.221-221
    • /
    • 1990
  • 진하 해수욕장은 부산에서 약 40km 정도 동해안도로를 거슬러 올라가면 경남 울주군 진하리에 위치한 조그마한 자연해변의 해수욕장이다. 해수욕장의 동쪽에서는 회야천이 흘러 들어오고, 이 하천의 3km 상류지점에는 댐을 축조하여 온산공단 및 주변지역의 생활용수를 공급하고 있다. 어울려서, 쾌적한 위락시설 단지로서는 최적이라고 생각된다. 현재 이 해안은 매년 침식이 진행되면서 해수욕을 할 수 있는 해변 공간이 줄어들고 있는 실정이다. 따라서 이 해안을 보전하기 위해서 관청과 주민들은 많은 심혈을 기울이고 있는 실정이다. 본 연구의 조사단은 1987년부터 해마다 수침측량을 실시하여 해수욕장의 지형변화를 조사하고 있다. 특히 이 해수욕장의 사빈은 몇년전 부터, 침식형의 사빈으로 변화되어 매년 많은 모래가 유실되는 현상이 발생하고 있어, 관청 및 주민들의 관심을 집중시키고 있다. 따라서, 금년에도 울주군청에서는 회야강 하구에 생성된 사주를 준설하여 준설된 모래를 해수욕장에 인공적으로 투입하여 양빈을 실시하고 있는 실정이다. 이 작업은 하구폐색의 문제를 해결할 뿐만 아니라 선박의 운행에도 큰 도움을 주고 있다. 이러한 작업은 기초해안 자료를 충분히 검토된 상태에서 실시되어야 한다. 그러치 못할 경우는 인위적으로 투입된 모래는 파랑에 의해서 다시 심해방향이나, 해안류를 따라서 다시 하구로 밀려오는 현상이 일어 날 것이다. 본 연구는 회야강 하구의 지형변화와 진하 해수욕장의 사빈의 변화를 정확히 파악하고져 단기간 동안 심천 측량을 실시한 결과를 이용하여 기존이론으로 해석한 결과를 제시함을 목적으로 한다.고 동시에 광 스트레스에 대한 저해를 감소시키는 것으로 보인다. 있다. 청주권의 무심천도 계획상은 대청댐의 물을 공급 받을수도 있도록 되어 있으나 현실상으로 상수도 원수로서의 공급마저도 매년 심한 원수 수질 문제(5-6월, 10월경의 취수장 부근의 부영양화 현상으로 인한 악취와 물 맛의 문제)를 1984년부터 겪고 있다. 이와 같이 도시권 하천의 수자원은 자연적, 인위적, 경제적, 법적, 제도적 여러 제한 요소로서 특성을 가지고 있으며 이는 날로 심해 가고 있는 실정이다. 그러므로 최적 물관리 시스템의 개발이 새로이 시작하는 수자원 개발 사업에서는 계획 단계에서부터 절실히 요구되는 바이며 기존 시설물의 관리 운영은 과감히 그 운영 관리 기준을 보완 재 정비하여야 할 것이다. 지금까지 대부분의 수자원 종합 개발 계획이 홍수방이나 용수 공급 및 수력 개발 등에 주력하여 왔으나 이제는 보다 더 수자원의 환경 보전적 차원과 도시의 안정적 발달을 위한 지역 및 권역 계획과 연계지워져서 양적인 안정 공급과 더불어 질적인 향상과 연계지워서 경제-사회적 요구에 부응할 수 있도록 도시권의 수자원을 최적 관리할 수 있는 방안을 강구하여야 할 것이다. 이는 각 도시 하천의 수자원의 정량적·정성적인 특성 및 제한 요소를 충분히 감안하여 수요-공급 개념에 의하여 과감히 기존 시설(예: 팔당댐의 운영, 대청댐의 운영 등)의 관리 운영 체계를 개선하여 나가야 할 것이며, 수질 보전적-환경 보전 차원에서 저수관리 체계를 확고히 할 수 있는 방안을 강구하여야 할 것이다.펄스주입법에 의해 증착된 박박은 강유전성 이력을 나타내었다.지역

  • PDF

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.

Guided-mode Resonances in Periodic Surface Structures Induced on Si Thin Film by a Laser (레이저에 의해 생성된 Si 박막의 주기적 표면 구조에서의 도파모드 공진 연구)

  • Ji Hyuk Lee;Yoon Joo Lee;Hyun Hong;Eun Sol Cho;Ji Young Park;Ju Hyeon Kim;Min Jin Kang;Eui Sun Hwang;Byoung-Ho Cheong
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.6
    • /
    • pp.241-247
    • /
    • 2023
  • We examine the spectral characteristics of laser-induced periodic surface structures (LIPSSs) formed on an amorphous silicon film irradiated by a 355-nm nanosecond laser. A Gaussian beam with a diameter of 196 ㎛ is used to perform a two-dimensional raster scan. The laser's pulse number is varied from 190 to 280, and its intensity is adjusted within 100-130 mJ/cm2. LIPSSs with a periodicity of approximately 330 nm form on the surface of the Si film, aligned perpendicular to the laser's polarization. Transmission spectra of the samples show dips around 700 nm for transverse electric polarization and around 500 nm for transverse magnetic polarization. The features are investigated with a one-dimensional-grating model using a rigorous coupled-wave analysis. Simulations confirm that the observed dips are due to the resonant modes, depending on the polarization.

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Bandwidth Enhancement of a Ultrasonic Transducer Using Double Acoustic Matching Layers- (어종식별을 위한 광대역 초음파 변환기의 설계 ( III ) - 이중음향정합층을 이용한 초음파 변환기의 대역폭 확장 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.85-95
    • /
    • 1998
  • The broadband ultrasonic transducers have been designed to use in obtaining the broadband echo signals from fish schools in relation to the identification of fish species. The broadening of bandwidth was achieved by attaching double acoustic matching layers on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and to evaluate the performance characteristics, such as the transmitting voltage response(TVR) of transducers. The constructed transducers were tested experimentally and numerically by changing the parameters such as impedances and thicknesses of the head, tail and matching layers, in the water tank. Also, the developed transducer was excited by a chirp signal and the received chirp waveforms were analyzed. According to the measured TVR results, the available 3 dB bandwidth of the transducer with double matching layers of an $Al_O_3/epoxy$ composite of 7 mm thick and a polyurethane window of 18 mm thick was 7.3 kHz with a center frequency of 38.8 kHz, and the maximum and the minimum values of the TVR in this frequency region were 135.7 dB and 132.7 dB re $1\;{\mu}Pa/V$ at 1 m, respectively. Also, the available 3 dB bandwidth of the transducer with double matching layers of an $Al_O_3/epoxy$ composite of 11 mm thick and a polyurethane window of 15 mm thick was 6.2 kHz with a center frequency of 38.6 kHz, and the maximum TVR value in the frequency region was 136.3 dB re $1\;{\mu}Pa/V$ at 1 m. Reasonable agreement between the experimental results and the numerical results for the TVR of the developed transducers was achieved. The frequency dependant characteristics of experimentally observed chirp signals closely matched to the measured TVR results. These results suggest that there is potential for increasing the bandwidth by varying other parameters in the transducer design and the material of the acoustic matching layers.

  • PDF

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.

Rapid Detection of Radioactive Strontium in Water Samples Using Laser-Induced Breakdown Spectroscopy (LIBS) (Laser-Induced Breakdown Spectroscopy (LIBS)를 이용한 방사성 스트론튬 오염물질에 대한 신속한 모니터링 기술)

  • Park, Jin-young;Kim, Hyun-a;Park, Kihong;Kim, Kyoung-woong
    • Economic and Environmental Geology
    • /
    • v.50 no.5
    • /
    • pp.341-352
    • /
    • 2017
  • Along with Cs-137 (half-life: 30.17 years), Sr-90 (half-life: 28.8 years) is one of the most important environmental monitoring radioactive elements. Rapid and easy monitoring method for Sr-90 using Laser-Induced Breakdown Spectroscopy (LIBS) has been studied. Strontium belongs to a bivalent alkaline earth metal such as calcium and has similar electron arrangement and size. Due to these similar chemical properties, it can easily enter into the human body through the food chain via water, soil, and crops when leaked into the environment. In addition, it is immersed into the bone at the case of human influx and causes the toxicity for a long time (biological half-life: about 50 years). It is a very reductive and related with the specific reaction that makes wet analysis difficult. In particular, radioactive strontium should be monitored by nuclear power plants but it is very difficult to be analysed from high-cost problems as well as low accuracy of analysis due to complicated analysis procedures, expensive analysis equipment, and a pretreatment process of using massive chemicals. Therefore, we introduce the Laser-Induced Breakdown Spectroscopy (LIBS) analysis method that analyzes the elements in the sample using the inherent spectrum by generating plasma on the sample using pulse energy, and it can be analyzed in a few seconds without preprocessing. A variety of analytical plates for samples were developed to improve the analytical sensitivity by optimizing the laser, wavelength, and time resolution. This can be effectively applied to real-time monitoring of radioactive wastewater discharged from a nuclear power plant, and furthermore, it can be applied as an emergency monitoring means such as possible future accidents at a nuclear power plants.

Development of 3D Viewer for Tree Cavity using Pulse Ultrasound (펄스 초음파를 이용한 수목 공동부 3D 구현 프로그램 제작)

  • Son, Jungmin;Kang, Sunghoon;Moon, Jongwook;Yoon, Seokkyu;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.265-271
    • /
    • 2021
  • The pattern of the tree's internal swelling depends on many causes. Since it is difficult to detect these various causes of swelling with a general method, if the state of swelling for a long time cannot be confirmed, serious damage to the trees may occur due to enlargement of the swelling area. In the method of acquiring a tree tomography image, an impulse passing through the tree is generated by tapping the sensor with a rubber mallet, and the moving speed is recorded. In this paper, to measure cracks, cavities, and swelling due to physical damage, we developed a 3D viewer that can know the internal state of a tree using a tree cross-section image acquired from Arbotom to determine the degree of swelling inside the tree. Based on this, we tried to present data that can be referred to when surgical operation of trees is required. In order to acquire a tomographic image of a tree, 6 sensors were attached to the three Yangpala and Maple trees, and a 1 m-long tree was measured using the Arbotom program, and a 3D image was implemented through the 3D Viewer created using MATLAB. In addition to simply acquiring images, the cross-sectional length and volume of the tree were measured. In the actually produced 3D Viewer, the length of the part where the swelling of the maple tree occurred was 33.12 cm, and the swelling of the yangpala tree was measured as 21.41 cm. The volume of the maple tree was measured to be 78.832 ㎤. As a result of comparing the cross-sectional image of the Arbotom and the 3D image, the same result as the real aspect of the tree was obtained, so it can be judged that the reliability of the manufactured software is also secured, and data to be applied to the surgical tree operation through the created Viewer is provided. It is believed that the damage will be minimized.