• Title/Summary/Keyword: 퍼지 PID 제어

Search Result 275, Processing Time 0.024 seconds

Implementation of Bilateral Control of fuzzy Robot Hand using Analytic Hierachy Process (계층적 분석방법을 이용한 퍼지 로봇 핸드의 양방향 제어의 구현)

  • 진현수
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2827-2830
    • /
    • 2003
  • Tele manipulator is distingushed from industrial robot by iterating same specified work. Manipulator operator is included in control loop for controlling the telemanipulator because he decide directly during the work and order controllabily reducing the modelling error of telemanipulator which depend on the PID controller. But position-force control method of bidirectional control impose unsafety of vibiration and Analytic Hierachy Method can stabilize for reducing nonlinear modelling error by expert operator because of transformation empirical control rule to linear model.

  • PDF

Analysis of the Effects of Scaling Factors of Fuzzy Controller (퍼지 제어기의 Scaling Factor의 영향 분석)

  • Lee, Chul-Heui;Seo, Seon-Hak
    • Journal of Industrial Technology
    • /
    • v.15
    • /
    • pp.195-202
    • /
    • 1995
  • In this paper, we analyze the effects of scaling factors on the performance of a fuzzy controller. The quantitative relation between input and output variables of a fuzzy controller is obtained by using a quasi-linear fuzzy model. And an approximate transfer function of a fuzzy controller is derived from the comparison of fuzzy controller with the conventional PID controller. Then we analyze the effects of scaling factor using this approximate transfer function and root locus method.

  • PDF

Design and Implementation for rubust Fuzzy Digital PI+D Control system (강인한 퍼지 디지털 PI+D 제어 시스템의 설계 및 구현)

  • 권태익;김태언;박윤명;박재형;임영도
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.137-140
    • /
    • 2001
  • In this paper, Fuzzzy Digital PI+D Controller plans for load, noise, plant change, Fuzzy Controller makes use of simple four rule and membership function, and plant used three phase Induction Motor. Characteristic of system compared from experimentation respectively the proposed Control System, Digital PID Control and Digital PI+D Control System.

  • PDF

The Design of Hybrid Fuzzy Controller for Inverted Pendulum (Inverted Pendulum을 위한 하이브리드 퍼지 제어기 설계)

  • Roh, Seok-Beom;Oh, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2702-2704
    • /
    • 2001
  • In this Letter, we propose a comprehensive design methodology of hybri'd Fuzzy controllers (HFC). The HFC comes as a form of a convex combination of a standard PID controller and a fuzzy controller. The design procedure dwells on the use of evolutionary computing (genetic algorithm) and an auto-tuning algorithm. The tuning of the scaling factors of the HFC is an essential component of the entire optimization process. A numerical study is presented and a detailed comparative analysis is also included.

  • PDF

The Hybrid Fuzzy Controller using the Hybrid Auto-tuning Algorithm (하이브리드 자동 동조 알고리즘을 이용한 하이브리드 퍼지 제어기)

  • Lee, Dae-Keun;Kim, Joong-Young;Oh, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.521-523
    • /
    • 1999
  • In this paper, we propose the hybrid fuzzy controller(HFC) and the hybrid auto-tuning algorithm. The proposed HFC combined a PID controller with a fuzzy controller concurrently produces the better output performance such as sensitivity improvement in steady state and robustness in transient state than any other controller. In addition, a hybrid auto-tuning algorithm which consists of genetic algorithm and complex algorithm to automatically generate weighting factor, scaling factors and PID control gains optimizes the output of HFC. As an typical example of non-linear system in control theory an inverted pendulum will be controlled by the suggested HFC and illustrated the performance and applicability of this proposed method by simulation.

  • PDF

Design of Fuzzy PID Controller Using GAs and Estimation Algorithm (유전자 알고리즘과 Estimation기법을 이용한 퍼지 제어기 설계)

  • Roh, Seok-Beom;Oh, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.416-419
    • /
    • 2001
  • In this paper a new approach to estimate scaling factors of fuzzy controllers such as the fuzzy PID controller and the fuzzy PD controller is presented. The performance of the fuzzy controller is sensitive to the variety of scaling factors[1]. The desist procedure dwells on the use of evolutionary computing(a genetic algorithm) and estimation algorithm for dynamic systems (the inverted pendulum). The tuning of the scaling factors of the fuzzy controller is essential to the entire optimization process. And then we estimate scaling factors of the fuzzy controller by means of two types of estimation algorithms such as Neuro-Fuzzy model, and regression polynomial [7]. This method can be applied to the nonlinear system as the inverted pendulum. Numerical studies are presented and a detailed comparative analysis is also included.

  • PDF

Design of Fuzzy Logic System for the Steam Generator Water Level Control of Nuclear Power Plants (원전 증기발생기 수위제어를 위한 퍼지 논리 시스템 설계)

  • Song, Un-Ji;Kwan, Dae-Hwan;Zheng, Bin;Yoo, Seog-Hwan;Choi, Byung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.328-330
    • /
    • 2005
  • Most of the water level controllers of the actual plant are PID controllers. But they have limitations in appling for tracking the set point and getting rid of disturbances, so there are some defects to apply in the actual ground even though many research works represented the resolution to solve it. In this paper, we design a fuzzy logic system (FLS) for controlling the steam generator water level in nuclear power plants. Some computer simulations reveal similar performance with the conventional PID controller.

  • PDF

HYBRID PID FLC using sliding Mode (슬라이딩 모드를 이용한 HYBRID PID형 퍼지제어기)

  • Moon, Jun-Ho;Cho, Jong-Hoon;Oh, Kwang-Hyun;Kim, Tae-Un;Nam, Moon-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.992-994
    • /
    • 1995
  • FLC has a good performance for complication system or unknown model by using human linguistic method but many part control design are based on expert knowledge or trial-error method and it is difficult to prove stability and robustness of controller. In this paper we improve this problem by setting fuzzy rules by dividing phase plane of error and rate of error change by switching surface. We can guarantee the stability in nonlinear system, and also in fuzzy PID type controller the complexity of controller design is increased by increasing the number of input variables and defining more range of operation if we want performance of more specific rules, thus we need to fine the method to decrease the number of control rules used in FLC design. In this paper the algorithm is validated by simulation using conventional FLC and proposed method.

  • PDF

A Study on Fuzzy Algorithm for PID Tuning of Turbine Speed Controller (수차 속도제어기의 PID 동조를 위한 퍼지 알고리즘에 관한 연구)

  • Kim, Y.G.;Paik, D.H.;Cho, N.B.;Shin, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.999-1001
    • /
    • 1995
  • In this study, the algorithm of optimal parameter inference is proposed. At this inferring method, we tried to acquire the follow-up to reference pattern through comparing the plant output pattern with random reference pattern. As an inference method, the fuzzy theory was applied and the proposed algorithm was proved by computer simulation.

  • PDF

Remote Fuzzy Logic Control of Networked Control System Via Profibus-DP (Profibus-DP를 이용한 네트워크 기반 제어 시스템의 원격 퍼지 제어)

  • Lee, Kyung-Chang;Lee, Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.4
    • /
    • pp.281-287
    • /
    • 2002
  • This paper investigates on the feasibility of fuzzy logic control for networked control systems. In order to evaluate its feasibility, a networked control system for motor speed control is implemented on a Profibus-DP network. The NCS consists of several inde-pendent, but interacting processes running on two separate stations. By using this NCS, the network-induced delay is analyzed to find the cause and effect of the delay. Furthermore, in order to prove the feasibility, the fuzzy logic controller's performance is compared with those of conventional PID controllers. Based on the experimental results, the fuzzy logic controller can be a viable choice far NCS due to its robustness against parameter uncertainty.