• Title/Summary/Keyword: 판별

Search Result 4,718, Processing Time 0.029 seconds

A Study on the Hull-dimension of 89 ton class Stow-net Vessel with Stern-fishing (89톤급 선미식 안강망어선의 선형치수에 관한 연구)

  • Park, Je-Ung;Lee, Hyeon-Sang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.159-165
    • /
    • 1997
  • This paper presents the optimum dimension of 89 ton class stow-net vessel with stern-fishing. The model of basic design is developed by using the optimization techniques referring to objective function and numerous constraints as follows; speed, fishing quantity, fishing days, catch per unit effort(CPUE), and weight/ratio of main dimensions, etc. Thus, the basic design of stow-net fishing vessel is built up by using the optimization of the design variables called the economic optimization criteria, and the objective function represents the criterion which is cost benefit ratio(CBR). The main conclusions are as follows. 1. S/W for decision of optimum hull size is developed in 89 ton class stow-net fishing vessel which is constructed with optimization of the design variables called the economic optimization criteria. 2. For optimum ship dimensions in 89 ton class stow-net fishing vessel, the hull dimensions can be obtained in the range of L= 27.3m, B = 6.6m, D = 2.80m, Cb = 0.695, T/D = 0.80, $\Delta$(displacement)=281.7ton with 10 knots.

  • PDF

Systematic Study on the Fishes of the Family Cobitidae(Pisces, Cypriniformes). 2. Taxonomic Study on the Cobitis taenia complex from Korea (기름종개과(family Cobitidae)어류의 계통분류에 관한 연구 2. 한국산 Cobitis taenia complex의 분류학적 고찰)

  • 양서영;이혜영;양홍준;전상린;박병상;김재흡
    • Animal Systematics, Evolution and Diversity
    • /
    • v.9 no.2
    • /
    • pp.151-170
    • /
    • 1993
  • Morphometric, band-pattern and electrophoretic analysis on Cobitis taenia complex were performed to investigate the morphological and genetic differentiation and to clarify their taxonomic status. Intermediate types of band-pattern (C and D type) were more frequently expressed than that of types of C. t. taenia(type A) and C. t. lutheri (type B). Sexual dimorphism of band-pattern was observed not only in C. t. taenia(type A) and C. t. lutheri(type B). Sexual dimorphism of band-pattern was observed not only in C. t. lutheri but also in C. t. taenia and C. t. striata as well. Discriminant function analysis based on 19 morphological characters shows no significant differences among C. taenia complex. The degree of genic variation of C. t. striata was higher ( =1.48, P=31.2%, HD=0.009) than those of C. t. striata was higher( =1.48, P=31.2%, HD=0.082 and HG=0.009) than those of C. t. lutheri ( =1.37, P=2.7%, HD=0.058 and HG=0.065). The average genetic similarities between C. t. lutheri and C. t. taenia-C. t. striata were S=0.62 and S=0.66 respectively and these values indicate that C. t. tanenia has evolved specific level of differentiation. C. t. striata and C. t. lutheri show subspecifc level of close genetic similarity (S=0.82). Based on the divergent time estimate (Nei, 1975) it is assumed that C. t. tanenia was branched off from the other subspecies about two million years before present (MYBP) and C. t. striata and C. t. lutheri were differentiated about 0.6 MYBP. The use of C. sinesis an the scientific name for the Korean C. t. taenia, proposed by Kim and Lee (1988) seems incorrect since they are quite different in the structure of lamina circularis (Vladycov, 1935), the external morphology and distribution (Cheng and Zheng, 1987) and the chromosome number(Yu et al., 1989). Kim and Lee(1988) also argued that C.t. striata and C. t. lutheri should be treated as distinct species but the present study and other reports (Kim and Lee, 1984; Kim and Yang, 1993) do not support it. We conclude that C. t. taenia is a good species and C. t. striata and C. t. lutheri are subspecific status. Their scientific names should be revised in the future.

  • PDF

A Study on Image Reconstruction for Seed Localization for Permanent Prostate Brachytherapy (전립선암 근접치료 시 방사성선원 위치확인을 위한 영상 재구성에 관한 연구)

  • Hong, Ju-Young;Rah, Jeong-Eun;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.125-133
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: This study was to design and fabricate a phantom for prostate cancer brachytherapy to validate a developed program applying a 3-film technique, and to compare it with the conventional 2-film technique for determining the location of an implanted seed. $\underline{Materials\;and\;Methods}$: The images were obtained from overlapped seeds by randomly placing a maximum of 63 seeds in the anterior-posterior (AP) position and at $-30^{\circ} to $30^{\circ} at $15^{\circ} intervals. Images obtained by use of the phantom were applied to the image processing procedure, and were then processed into the development program for seed localization. In this study, cases were set where one seed overlapped, where two seeds overlapped and where none of the three views resolved all seeds. The distance between the centers of each seed to the reference seed was calculated in a prescribed region. This distance determined the location of each seed in a given band. The location of the overlapped seeds was compared with that of the 2-film technique. $\underline{Results}$: With this program, the detection rate was 92.2% (at ${\pm}15^{\circ}), 94.1% (at ${\pm}30^{\circ}) and 70.6% (compared to the use of the 2-film technique). The overlaps were caused by one or more than two seeds that overlapped; the developed program can identify the location of each seed perfectly. However, for the third case the program was not able to resolve the overlap of the seeds. $\underline{Conclusion}$: This program can be used to improve treatment outcome for the brachytherapy of prostate cancer by reducing the number of errors in the process of reconstructing the locations of perfectly overlapped seeds.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Assessment of Hydroureteronephrosis in Children Using Diuretic Radionuclide Ureterography (동위원소 이뇨 요관그람을 이용한 소아 요관폐쇄의 평가)

  • Kim, Jong-Ho;Lee, Dong-Soo;Kwark, Cheol-Eun;Lee, Kyung-Han;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Choi, Yong;Choi, Hwang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.75-84
    • /
    • 1994
  • The need for assessment of ureteric function in the patient with an obviousely dilated ureter has increased particularly with the added spectrum of asymptomatic patients presenting with hydrone-phrosis and hydroureter on antenatal and perinatal ultrasound. To assess the influence of ureteral status on kidney washout during $^{99m}Tc$-DTPA diuretic renography, ureteral images were reviewed in 80 children referred for hydronephrosis. A scintigraphically abnormal ureter was defined as an intense and continuous image of > 10 min during diuretic renography. Out of them, a total of 16 nephroureteral systems in 12 children with scintigraphically abnormal ureter were analyzed. A diuretic washout index using response half time (t1/2) by linear fitting after lasix injection, was determined on renal (Kt1/2) and ureteral (Ut1/2) curves (diuretic renogram vs. diuretic ureterogram). Diuretic ureterogram curve patterns corresponding to normal (type I), obstructive (II) and non-obstructive (III) cases were described. Compared with X-ray data, diuretic renography was highly sensitive (88%) and specific (99%) for detecting any ureteral abnormality. Despite an obstructive Kt1/2 (>20 min), no patient with an abnormal ureter underwent therapy at the ureteropelvic junction because the hydronephrosis regressed after surgery at the lower level. Our data indicate that the abnormal ureter findings during diuretic renography have to be recognized before therapy for children with hydeonephrosis.

  • PDF

Diagnostic Accuracy of Rest T1-201/Stress Tc-99m-MIBI Myocardial SPECT in the Diagnosis of Coronary Artery Disease (휴식 T1-201/부하 Tc-99m MIBI 심근 SPECT의 관상동맥질환 진단 정확성)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Kang, Keon-Wook;Sohn, Dae-Won;Oh, Byung-Hee;Lee, Myung-Mook;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.112-117
    • /
    • 1996
  • Objective: Standard stress/rest Tc-99m MIBI and T1-201 myocardial perfusion study have some limitations such as stress/rest image overlap for Tc-99m-MIBI, low energy for T1-201 and long period of study time for two separate studies. Separate acquisition rest T1-201/stress Tc-99m MIBI dual isotope study is a potentially efficient myocardial perfusion imaging protocol that combines the high resolution of Tc-99m for stress perfusion assessment and T1-201 for viability assessment. This study assessed the usefulness and diagnostic accuracy for this new approach. Methods: We tried to evaluate sensitivity and specificity of dual isotope separate acquisition protocol in 67 patients. Immediately after resting T1-201 SPECT data was acquired, dipyridamole stress Tc-99m MIBI myocardial perfusion study was performed. Visual analysis was carried out qualitatively with 0 to 3 scoring system for 17 segments of left ventricle in the reconstructed horizontal long axis and short axis slices. Results: Total study was completed within 3 hours. In angiographic correlation, dual isotope SPECT demonstrated high sensitivity(85%) and in a small group of patients, high specificity was also observed (100%). Conclusion: Combined thallium-201/stress Tc-99m MIBI SPECT displayed similiar diagnostic accuracy to protocol using stress/rest Tc-99m MIBI SPECT. This protocol was completed in shorter period than the previous protocols and therefore enhance laboratory throughput and patients convenience.

  • PDF

The Role of T1-201 Brain SPECT in the Differentiating Recurrent Tumor from Radiation Necrosis (뇌종양의 재발과 방사선 괴사의 감별을 위한 탈륨 SPECT의 역할)

  • Won, Kyoung-Sook;Ryu, Jin-Sook;Moon, Dae-Hyuk;Yang, Seoung-Oh;Lee, Hee-Kyung;Lee, Jung-Kyo;Kwun, Byung-Duk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.476-483
    • /
    • 1996
  • Following radiation therapy for brain tumors, patients often have clinical deterioration due to either radiation necrosis or recurrent tumor progression in the treatment field. The distinction between these entities is important but difficult clinically or even with CT or MRI. T1-201 has been known to accumulate in various tumors and be useful to grade, predict prognosis or detect recurrence of glioma. The aim of this study was to evaluate the usefulness of T1-201 SPECT in the differentiation of recurrent tumor from radiation necrosis. Of 67 patients who did T1-201 brain SPECT imaging with clinically suspected recurrent tumor or radiation necrosis, 20 patients underwent histopathological examination and constituted the study population. T1-201 uptake indices on T1-201 brain SPECT imaging rrere calculated and correlated with histopathological diagnosis. Of 20 patients, 15 were histopathologically confirmed as recurrent original tumor or malignant transformation of benign tumor and 5 were diagnosed as radiation necrosis. On T1-201 SPECT, 18 of 20 had T1-201 index above 2.5 which was regarded as positive indicator for the presence of tumor. Seventeen cases showed concordance, which consisted of 15 true positive and 2 true negative. Discordant 3 cases were all false positive. There was no case of false negative. The sensitivity, specificity, positive and negative predictive value of T1-201 SPECT were 100%, 40%, 83% and 100%. In conclusion, T1-201 brain SPECT is a sensitive diagnostic test in the detection of recurrent tumor following radiation therapy and is useful in the differentiation of recurrent tumor from radiation necrosis. Relatively low specificity should be evaluated further in larger number of patients in consideration of sampling error and referral bias for pathologic examination.

  • PDF

Interobserver Reproducibility of Segmental Scoring of $^{99m}Tc$-MIBI Myocardial SPECT ($^{99m}Tc$-MIBI 심근 SPECT의 분절 육안 분석시 판독자간의 일치도)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Lee, Kyung-Han;Kim, Jong-Ho;Shon, Kyung-Soo;Cho, Sung-Wook;Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul;Seo, Jeong-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.317-325
    • /
    • 1994
  • The accuracy of dipyridamole stress/rest $^{99m}Tc$-MIBI myocardial imaging for detection of ischemia depends on reproducible image interpretation. To evaluate the reproducibility of visual assessment, agreement in interpretation among two independent observers, blind-ed to clinical data, was evaluated in SPECT images of 131 patients (94 males, 38 females; mean age $58{\pm}7yr$) with suspected coronary artery disease who underwent both dipyridamole stress/rest $^{99m}Tc$-MIBI myocardial SPECT and coronary angiography. The left ventricle was divided into twenty-nine segments in stress and rest SPECT images and each segment was visually graded according to a five-point scale (segmental score : 0=normal, 1=equivocal, 2=mild decrease, 3=severe decrease and 4=absent uptake). Overall concordance of segmental scoring between the two observers was 80%. The Pear-son's correlation coefficient (r) of the segmental scores for stress and rest images were 0.67 and 0.65, respectively, while the difference in score between the two images showed a correlation of 0.45 (all p<0.001). Agreement between two observers in final SPECT diagnosis as absence or presence of disease was 93%. The degree of agreement in segmental scoring showed no difference between patients with or without agreement as to the presence of disease. Therefore it appeared that cases with inconcordant diagnosis between the 2 observers were mainly due to a difference in individual threshold for interpretating the significance of a particular decreased uptake area rather than to a difference in perceiving the degree of the hypoactivity Thus, establishment of individual optimum thresholds in visual interpretation of myocardial SPECT may be helpful to improve reproducibility and accuracy of scan diagnosis.

  • PDF

Environmentally Associated Spatial Distribution of a Macrozoobenthic Community in the Continental Shelf off the Southern Area of the East Sea, Korea (한국 동해 남부해역 대륙붕에 서식하는 대형저서동물군집 공간분포를 결정하는 환경요인)

  • Lee, Jung-Ho;Lee, Jung-Suk;Park, Young-Gyu;Kang, Seong-Gil;Choi, Tae Seob;Gim, Byeong-Mo;Ryu, Jongseong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.1
    • /
    • pp.66-75
    • /
    • 2014
  • This study aims to understand environmental factors that determine spatial distribution of macrozoobenthic community in the southern area (ca 100-500 m depth) of East Sea, Korea, known as a candidate site for carbon storage under the seabed. From sixteen locations sampled in the summer of 2012, a total of 158 species were identified, showing density of $843indiv/m^2$ and biomass of $26.2g\;WW/m^2$, with increasing faunal density towards biologically higher diverse locations. Principal component analysis showed that a total of 33 environmental parameters were reduced to three principal components (PC), indicating sediment, bottom water, and depth, respectively. As sand content was increasing, number of species increased but biomass decreased. Six dominant species including two bivalve species favored high concentrations of ${\Omega}$ aragonite and ${\Omega}$ calcite, indicating that the corresponding species can be severely damaged by ocean acidification or $CO_2$ effluent. Cluaster analysis based on more than 1% density dominant species classified the entire study area into four faunal assemblage (location groups), which were delineated by characteristic species, including (A) Ampelisca miharaensis, (B) Edwardsioides japonica, (C) Maldane cristata, (D) Spiophanes kroeyeri, and clearly separated in terms of geography, bottom water and sediment environment. Overall, a discriminant function model was developed to predict four faunal assemblages from five simply-measured environmental variables (depth, sand content in sediment, temperature, salinity and pH in bottom water) with 100% accuracy, implying that benthic faunal assemablages are closed linked to certain combinations of abiotic factors.

True Orthoimage Generation from LiDAR Intensity Using Deep Learning (딥러닝에 의한 라이다 반사강도로부터 엄밀정사영상 생성)

  • Shin, Young Ha;Hyung, Sung Woong;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.4
    • /
    • pp.363-373
    • /
    • 2020
  • During last decades numerous studies generating orthoimage have been carried out. Traditional methods require exterior orientation parameters of aerial images and precise 3D object modeling data and DTM (Digital Terrain Model) to detect and recover occlusion areas. Furthermore, it is challenging task to automate the complicated process. In this paper, we proposed a new concept of true orthoimage generation using DL (Deep Learning). DL is rapidly used in wide range of fields. In particular, GAN (Generative Adversarial Network) is one of the DL models for various tasks in imaging processing and computer vision. The generator tries to produce results similar to the real images, while discriminator judges fake and real images until the results are satisfied. Such mutually adversarial mechanism improves quality of the results. Experiments were performed using GAN-based Pix2Pix model by utilizing IR (Infrared) orthoimages, intensity from LiDAR data provided by the German Society for Photogrammetry, Remote Sensing and Geoinformation (DGPF) through the ISPRS (International Society for Photogrammetry and Remote Sensing). Two approaches were implemented: (1) One-step training with intensity data and high resolution orthoimages, (2) Recursive training with intensity data and color-coded low resolution intensity images for progressive enhancement of the results. Two methods provided similar quality based on FID (Fréchet Inception Distance) measures. However, if quality of the input data is close to the target image, better results could be obtained by increasing epoch. This paper is an early experimental study for feasibility of DL-based true orthoimage generation and further improvement would be necessary.