1 |
Grimm PD, Blasko JC, Sylvester JE, Meier RM, Cavanagh W. 10-year biochemical (prostate-specific antigen) control of prostate cancer with (125) brachytherapy. Int J Radiat Oncol Biol Phys 200151:31-40
|
2 |
Amols HI. Rosen II. A three-film technique for reconstruction of radioactive seed implants. Med Phys 1981;8:210-214
DOI
ScienceOn
|
3 |
Brinkmann DH, Kline RW. Automated seed localization from CT datasets of the prostate. Med Phys 1998;25:1667-1672
DOI
ScienceOn
|
4 |
Todor DA, Zaider M, Cohen GN, Worman MF, Zelefsky MJ. Intraoperative dynamic dosimetry for prostate implants. Phys Med Biol 2003;48:1153-1171
DOI
ScienceOn
|
5 |
Suy, Davis BJ, Herman MG, Robb RA. Prostate brachytherapy seed localization by analysis of multiple projections: identifying and addressing the seed overlap problem. Med Phys 2004;31:1277-1287
DOI
ScienceOn
|
6 |
Lam ST, Cho PS, Marks RJ 2nd, Narayanan S. Threedimensional seed reconstruction for prostate brachytherapy using Hough trajectories. Phys Med Biol 2004;49:557-569
DOI
ScienceOn
|
7 |
Otsu N. A threshold selection method from gray-level histograms. IEEE Trans Systems Man and Cybernetics 1979;79:62-B6
|
8 |
Rosenthal MS, Nath R. An automatic seed identification technique for interstitial implant using three isocentric radiographs. Med Phys 1983;10:475-479
DOI
ScienceOn
|
9 |
Altschuler MD, Findlay PA, Epperson RD. Rapid, accurate, three-dimensional location of multiple seeds in implant radiotherapy treatment planning. Phys Med Biol 1983;28:1305-1318
DOI
ScienceOn
|
10 |
Narayanan S, Cho PS, Marks R J II. Fast cross-projection algorithm for reconstruction of seeds in prostate brachytherapy. Med Phys 2002;29:1572-1579
DOI
ScienceOn
|
11 |
Narayanan S, Cho PS, Marks R J II. Three-dimensional seed reconstruction from an imcomplete data set for prostate brachytherapy. Phys Med Biol 2004;49:3483-3494
DOI
ScienceOn
|
12 |
Haralick RM, Sternberg SR, Zhuang X. Image analysis using mathematical morphology. IEEE Trans Pattern Anal Mach Intell 1987;3:532-550
|
13 |
Pizer SM, Amburn EP, Austin JD, et al. Adaptive histogram equalization and its variations. Com put Graphics Image Process 1987;39:355-368
DOI
|
14 |
Jackson DD. An automatic method for localizing radioactive seeds in implant dosimetry. Med Phys 1983;10:370-372
DOI
ScienceOn
|
15 |
Tubic D, Zaccarin A, Beaulieu L, Pouliot J. Automated seed detection and three-dimensional reconstruction. II. Reconstruction of permanent prostate implants using simulated annealing. Med Phys 2001;28:2272-2279
DOI
ScienceOn
|
16 |
Bice WS Jr, Dubois DF, Prete JJ, Prestidge BR. Source localization from axial image sets by iterative relaxation of the nearest neighbor criterion. Med Phys 1999;26:1919-1924
DOI
ScienceOn
|
17 |
Tubic D, Zaccarin A, Pouliot J, Beaulieu L. Automated seed detection and three-dimensional reconstruction. I. Seed localizationfrom fluoroscopic images or radiographs. Med Phys 2001 ;28:2265-2271
DOI
ScienceOn
|
18 |
Roy JN, Wallner KE, Harrington PJ, Ling CC, Anderson LL. A CT-based evaluation method for permanent implants: application to prostate. Int J Radiat Oncol Bioi Phys 1993; 26:163-169
DOI
ScienceOn
|