• Title/Summary/Keyword: 파절양상

Search Result 166, Processing Time 0.028 seconds

The Effect of Thickness of Porcelain on Shear Bond Strength Between Heat-Pressed Porcelain and Non-Precious Metal (도재의 두께가 하부금속과의 전단결합강도에 미치는 영향)

  • Jo, Jung-Min;Lee, Cheong-Hee;Lee, Kyu-Bok;Cho, Jin-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.223-232
    • /
    • 2012
  • The purpose of this study was to investigate the effect of various thickness of porcelain on shear bond strength between metal coping and porcelain. So, various thickness of feldspathic porcelain and heat-pressed porcelain were built up and compared. 120 metal cube($4{\times}4{\times}4mm$) specimens were prepared. 60 specimens were applied to feldspathic porcelain and the others were applied to heat-pressed porcelain by 1mm, 1.5mm, 2mm, 2.5mm, 3mm and 3.5mm thickness. The measurement of shear bond strength was performed by Instron universal testing machine. The following results were obtained from this study. 1. As thickness of feldspathic porcelain increases, shear bond strength has decreased. Feldspathic specimens with 1mm porcelain thickness were significantly stronger than other feldspathic subgroups. 2. There was no significant difference of shear bond strength according to porcelain thickness in heat-pressed porcelain group. 3. In comparison between subgroups with same thickness, feldspathic porcelain group had stronger shear bond strength than heat-pressed porcelain. There were significant difference between 1mm and 3mm porcelain thickness group. 4. In almost cases, fracture surface was found on both metal and porcelain surfaces. As thickness of porcelain was increased, metal exposure was decreased.

A Retrospective Study of the Pattern and Treatment of Traumatic Dental Injury to Primary and Permanent Teeth (유치와 영구치의 외상 양상 및 치료에 대한 후향적 연구)

  • Kim, Yujeong;Kim;Choi, Namki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.4
    • /
    • pp.314-321
    • /
    • 2014
  • This study investigated the pattern and treatment of traumatic dental injury (TDI), with respect to the time elapsed prior to the initial visit to the Department of Pediatric Dentistry, Chonnam National University Dental Hospital for TDI, from January 2009 to December 2013. The dental trauma records of a total of 378 patients (940 traumatic teeth) were analyzed. The prevalence rate of dental trauma was twofold higher in males versus females. The principal cause of injury, among all participants, was falling (36.5%). The most commonly affected teeth were the maxillary central incisors (66.9%). Subluxation (43.9%) represented the most common trauma for primary teeth, and uncomplicated crown fracture in permanent teeth (30.9%). Only 10% of patients visited the dental clinic within 1 hour of sustaining trauma. The principal treatment provided for primary teeth, during the initial clinical visit, was follow-up (53.2%); for permanent teeth it was root canal treatment (27.3%). The prevalence of root canal treatment for permanent teeth increased commensurate with the time elapsed since injury. These data suggest that delayed checkup following trauma may increase the risk of loss of pulp vitality.

A STUDY ON THE TRAUMATIC INJURIES TO PRIMARY TEETH (유치 외상에 관한 연구)

  • Chung, Youn-Joo;Kim, Kwang-Chul;Park, Jae-Hong;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.328-337
    • /
    • 2010
  • The purpose of this study was to research the traumatized primary teeth and investigate following factors: sex, age, cause, place and time(of the year) of injury, elapsed time, area and type of injury, dental treatment and prognosis. The analysis includes total of 1533 traumatized primary teeth from 758 children aging from 6 months to 6 years(mean age: 2.8) from 2003 to 2007. The result follows : 1. The children of age between 1-2 and 2-3 were involved in the largest number of injuries in both sexes with boy/girl ratio of 1.77:1(p<0.001). 2. Fall and collision were the main causes of traumatic dental injury, especially in younger children(p<0.05). Places of injury occurrence varied: home, outdoors, and kindergarten. Warm climate accounts for frequent outdoor injuries in May, September and October(p<0.001). 3. Most of the children visited dental clinic within 24 hours of the injury(77.6%). From March to September, dental trauma occurrences were distributed evenly, except for Winter period(p<0.001). 4. Upper central incisors were the most commonly affected teeth, and the injuries usually involved 1 tooth or 2 teeth. 5. Periodontal tissue injuries dominated and subluxation was the most common type. Lateral luxation, enamel fracture, intrusion and root fracture followed.

A Epizootiological Study of Salmonella Infection on Piggery : II. A Study on Drug Resistance and R Plasmids in Salmonella (양돈장(養豚場)에 있어서 Salmonella 감염증(感染症)의 역학적(疫學的)인 연구(硏究) : II. Salmonella 속균(屬菌)의 약제내성(藥劑耐性) 및 전달성(傳達性) R plasmid)

  • Choi, Won-pil;Lee, Hi-suk;Yeo, Sang-geon;Lee, Hun-jun;Jung, Suk-chan
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.2
    • /
    • pp.229-235
    • /
    • 1986
  • 1984년 5월부터 1985년 5월까지 대구(大邱), 경북(慶北), 경남(慶南) 및 충남지역(忠南地域) 7개(個) 양돈장(養豚場)의 자돈(仔豚) 및 성돈(成豚)의 분변(糞便) 및 양돈장(養豚場)의 흙, 하수(下水), 사료(飼料), 추비(推肥), 쥐 등 7,440예(例)와 대구시(大邱市) 도축장(屠畜場)의 도축돈(屠畜豚) 장간막임파절(腸間膜淋巴節) 및 직장내용물(直腸內容物) 555예(例)로부터 분리(分離)한 319주(株)의 Salmonelia속균(屬菌)을 대상으로 항균제(抗菌劑)에 대한 내성(耐性) 및 전달성(傳達性) R plasmid의 분포상황(分布狀況)을 조사(詞査)하였던 바 그 결과(結果)는 다음과 같다. 1. 공시균(供試菌) 319주(株) 중(中) 250주(株)(78.4%)가 ampicillin(An), chloramphenicol(Cm), gentamicin(Gm), kanamycin(Km), nalidixic acid(Na), rifampicin(Rf), streptomycin(Sm), sulfadimethoxine(Su), 또는 tetracycline(Tc)에 내성(耐性)을 나타내었으며, 약제별(藥劑別)로는 Su(74.9%), Sm(53.0%) 및 Tc(28.5%)에 높은 내성(耐性)이 인정(認定)되었다. 2. 내성균(耐性菌) 250주(株)의 전달성(傳達性) R plasmid 보유율(保有率)은 51.2%(128주(株))였으며, 약제별(藥劑別)로는 Am경우 100%, Tc 92. 3% 및 Cm 75.0% 순으로 보유율(保有率)이 높았다. 3. 내성균(耐性菌) 250주(株)의 내성양상(耐性樣相)은 SmSu(91주(株)), Su(59주(株)) 및 TcSmSu(50주(株))내성형(耐性型)이 대부분이었고 R plasmid 전달후(傳達後)의 내성양상(耐性樣相)은 TcSmSu(40주(株)) 및 TcSu(28주(株)) 내성형(耐性型)이 많았다. 4. 양돈장별(養豚場別) 내성균(耐性菌) 출현빈도(出現頻度)는 48.0~93.6%로 다양(多樣)하였고, 전달성(傳達性) R plasmid 보유율(保有率)은 0~77.8%로 내성균(耐性菌) 출현빈도(出現頻度)와 일치(一致)되지 않았다. 5. 공시균(供試菌) 319주(株) 중(中) 각각(各各) 2주(株)는 Rf 및 Gm에 대해 내성(耐性)을 나타내었고, 내성균(耐性菌) 250주(株) 중(中) 73.2%(183주(株))가 다제내성(多劑耐性)이었으므로 Salmonella의 다제내성화(多劑耐性化) 경향(傾向)이 있었다. 6. 내성균(耐性菌) 250주(株) 중(中) R plasmid 전달후(傳達後) 5주(株)는 TcAmCmSmSu내성형(耐性型), 1주(株)는 TcAmKmSmSu내성형(耐性型)임이 확인되었다.

  • PDF

THE EFFECTS OF THE FLUORIDE CONCENTRATION OF ACIDULATED BUFFER SOLUTIONS ON DENTINE REMINERALIZATION (유기산 완충용액의 불소농도가 상아질의 재광화에 미치는 영향)

  • Han, Won-Sub;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.526-536
    • /
    • 2009
  • The aim of this vitro-study is to evaluate the effects of fluoride on remineralization of artificial dentine caries. 10 sound permanent premolars, which were extracted for orthodontic reason within 1 week. were used for this study. Artificial dentine caries was created by using a partially saturated buffer solution for 2 days with grounded thin specimens and fractured whole-body specimens. Remineralization solutions with three different fluoride concentration (1 ppm. 2 ppm and 4 ppm) were used on demineralized-specimens for 7 days. Polarizing microscope and scanning electron microscope were used for the evaluation of the mineral distribution profile and morphology of crystallites of hydroxyapatite. The results were as follows: 1. When treated with the fluoride solutions, the demineralized dentine specimens showed remineralization of the upper part and demineralization of the lower part of the lesion body simultaneously. 2. As the concentration of fluoride increased, the mineral precipitation in the caries dentine increased. The mineral precipitation mainly occurred in the surface layer in 1 and 2 ppm- specimens and in the whole lesion body in 4 ppm -specimens. 3. When treated with the fluoride solution, the hydroxyapatite crystals grew. This crystal growth was even observed in the lower part of the lesion body which had shown the loss of mineral.

EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS (Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향)

  • Oh, Eun-Hwa;Choi, Kyoung-Kyu;Kim, Jong-Ryul;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.148-161
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of chlorhexidine (CHX) on microtensile bond strength (${\mu}TBS$) of dentin bonding systems. Dentin collagenolytic and gelatinolytic activities can be suppressed by protease inhibitors, indicating that MMPs (Matrix metalloproteinases) inhibition could be beneficial in the preservation of hybrid layers. Chlorhexidine (CHX) is known as an inhibitor of MMPs activity in vitro. The experiment was proceeded as follows: At first, flat occlusal surfaces were prepared on mid-coronal dentin of extracted third molars. GI (Glass Ionomer) group was treated with dentin conditioner, and then, applied with 2 % CHX. Both SM (Scotchbond Multipurpose) and SB (Single Bond) group were applied with CHX after acid-etched with 37% phosphoric acid. TS (Clearfil Tri-S) group was applied with CHX, and then, with adhesives. Hybrid composite Z-250 and resin-modified glass ionomer Fuji-II LC was built up on experimental dentin surfaces. Half of them were subjected to 10,000 thermocycle, while the others were tested immediately. With the resulting data, statistically two-way ANOVA was performed to assess the ${\mu}TBS$ before and after thermo cycling and the effect of CHX. All statistical tests were carried out at the 95 % level of confidence. The failure mode of the testing samples was observed under a scanning electron microscopy (SEM). Within limited results, the results of this study were as follows; 1. In all experimental groups applied with 2 % chlorhexidine, the microtensile bond strength increased, and thermo cycling decreased the micro tensile bond strength (P > 0.05). 2. Compared to the thermocycling groups without chlorhexidine, those with both thermocycling and chlorhexidine showed higher microtensile bond strength, and there was significant difference especially in GI and TS groups. 3. SEM analysis of failure mode distribution revealed the adhesive failure at hybrid layer in most of the specimen. and the shift of the failure site from bottom to top of the hybrid layer with chlorhexidine groups. 2 % chlorhexidine application after acid-etching proved to preserve the durability of the hybrid layer and microtensile bond strength of dentin bonding systems.

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

THE EFFECTS OF DRYING AGENTS AND BONDING AGENTS ON THE SHEAR BOND STRENGTH OF SEALANTS TO ENAMEL (치면건조제와 접착제의 사용에 따른 치면열구전색재의 전단결합강도에 관한 연구)

  • Lim, Hyun-Hwa;Jang, Ki-Taek;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.196-203
    • /
    • 2003
  • The application of sealants is a highly technique-sensitive procedure, requiring an extremely dry field prior to placement. Moisture contamination of the etched enamel surface before sealant placement is cited as the main reason for sealant failure. The purpose of this study was to evaluate the effects of different methods of sealant application on the shear bond strength of sealants to enamel. In groups 1, 2, 3, 4 Teethmate(unfilled sealant) was used, while Ultraseal XTplus(filled sealant) was used in groups 5, 6, 7, 8. Groups 1 and 5(control) were acid etched for 15 seconds using 35% phosphoric acid, washed and then dried. In groups 2, 6 drying agents were applied, and in groups 3, 7 bonding agents were applied and light cured. In groups 4 and 8 both drying agent and bonding agent were applied. Then sealant was cured to the specimen using molds 3mm in diameter and 2mm in height. Thermocycling was performed and shear bond strength was finally measured. The following results were obtained : 1. Groups using filled sealant(groups 5, 6, 7, 8) showed higher shear bond strengths compared to groups using unfilled sealant(groups 1, 2, 3, 4). 2. Among groups using unfilled sealant(groups 1, 2, 3, 4), groups 2, 3, 4 showed significantly higher shear bond strength compared to group 1(p<0.05). There were no significant differences among groups 2, 3 and 4. 3. There were no significant differences(p>0.05) among groups using filled sealant(groups 5, 6, 7, 8). 4. When modes of fracture were examined, cohesive failure was observed in groups 2, 3 and 4.

  • PDF

Three-Dimensional Finite Element Analysis of Internal Connection Implant System (Gsii$^{(R)}$) According to Three Different Abutments and Prosthetic Design (국산 내부연결형 임플란트시스템(GS II$^{(R)}$)에서 지대주 연결방식에 따른 응력분석에 관한 연구)

  • Jang, Mi-Ra;Kwak, Ju-Hee;Kim, Myung-Rae;Park, Eun-Jin;Park, Ji-Marn;Kim, Sun-Jong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.179-195
    • /
    • 2010
  • In the internal connection system, the loading transfer mechanism within the inner surface of the implant and also the stress distribution occuring to the mandible can be changed according to the abutment form. Therefore it is thought to be imperative to study the difference of the stress distribution occuring at the mandible according to the abutment form. The purpose of this study was to assess the loading distributing characteristics of three different abutments for GS II$^{(R)}$ implant fixture(Osstem, Korea) under vertical and inclined loading using finite element analysis. Three finite element models were designed according to three abutments; 2-piece Transfer$^{TM}$ abutment made of pure titanium(GST), 2-piece GoldCast$^{TM}$ abutment made of gold alloy(GSG), 3-piece Convertible$^{TM}$ abutment with external connection(GSC). This study simulated loads of 100N in a vertical direction on the central pit(load 1), on the buccal cusp tip(load 2) and $30^{\circ}$ inward inclined direction on the central pit(load 3), and on the buccal cusp tip(load 4). The following results were obtained. 1. Without regard to the loading condition, greater stress was concentrated at the cortical bone contacting the upper part of the implant fixture and lower stress was taken at the cancellous bone. 2. When off-axis loading was applied, high stress concentration observed in cervical area. 3. GSG showed even stress distribution in crown, abutment and fixture. GST showed high stress concentration in fixture and abutment screw. GSC showed high stress concentration in fixture and abutment. 4. Maximum von Mises stress in the surrounding bone had no difference among three abutment type. In GS II$^{(R)}$ conical implant system, different stress distribution pattern was showed according to the abutment type and the stress-induced pattern at the supporting bone according to the abutment type had no difference among them.

THE EFFECTS OF MECHANICAL AND THERMAL FATIGUE ON THE SHEAR BOND STRENGTH OF ORTHODONTIC ADHESIVES (기계적 및 열적 피로가 교정용 접착제의 결합강도에 미치는 영향)

  • Shin, Wan-Cheal;Kim, Jong-sung;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.175-186
    • /
    • 1996
  • The purpose of this study was to examine the effects of mechanical and thermal fatigue on the shear bond strength(SBS) of stainless steel mesh brackets bonded to human premolar teeth with 3 no-mix adhesives. The stainless steel mesh bracket was Ormesh(Ormco, .022 slot) and three types of no-mix adhesives were Ortho-one(Bisco), $Monolok^2$(RMO), $System\;1^+$(Ormco). The $10^6$ loadcycles of $17.4{\times}10^2sin2{\pi}ftlg{\cdot}cm$ and the 1,000 thermocycles of 15 second dwell time in each bath of $5^{\circ}C\;and\;55^{\circ}C$ were acturated as mechanical and thermal fatigue stress, and SBS were measured after each fatigue test. The fracture sites were analyzed by stereoscope and scanning electron microscope. The results obtained were summarized as follows; 1. Before thermocycles, $Monolok^2$ showed the highest Knoop hardness number(KHN, $64.03kg/mm^2$) and $System\;1^+$ showed the lowest value($31.60kg/mm^2$). After thermocycling, $Monolok^2$ also showed the highest KHN($38.03kg/mm^2$) and $system\;1^+$ showed the minimum($20.87kg/mm^2$). The KHN of Ortho-one, $Monolok^2,\;System\;1^+$ significantly decreased after thermocycling (P<0.01). 2. In static shear bond test, three adhesives had no significant differences in the SBS(P>0.01). 3. After thermocycling test, $Monolok^2$ showed the maximum SBS($19.34{\pm}2.75MPa$) and Ortho-one showed the minimum SBS($13.66{\pm}2.23MPa$). The SBS of Ortho-one(P<0.01) and $System\;1^+$(P<0.05) significantly decreased after $10^3$ thermocycles. 4. The SBS of three adhesives after $10^6$ loadcycles were similar and were not significantly decreased compared with static group(P>0.01). 5. The failure sites were usually bracket/resin interface in all groups irrespective of experimental conditions.

  • PDF