• Title/Summary/Keyword: 파손율

Search Result 140, Processing Time 0.027 seconds

Fabrication and loss measurement of $P_2O_5-SiO_2$ optical waveguides on Si (Si을 기판으로한 $P_2O_5-SiO_2$ 광도파로의 제작 및 손실측정)

  • 이형종;임기건;정창섭;정환재;김진승
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.258-265
    • /
    • 1992
  • A low loss optical waveguide of $P_{2}O_{5}-SiO_{2}$on Si substrate is produced by using the chemical vapour deposition method of $SiO_2$ thin films used in Si technology. Propagation loss of the waveguide layer was 1.65 dB/cm as produced and reduced down to 0.1 dB/cm after heat treatment at $1100^{\circ}C$. By using laser lithography and reactive ion etching method $P_{2}O_{5}-SiO_{2}$ waveguide was produced and subsequently annealed at $1100^{\circ}C$.As a result of this annealing the shape of the waveguide core was changed from rectangular to semi-circular form, and the propagation loss was reduced as down to 0.03 dB/cm at 0.6328$\mu$m and 0.04dB/cm at 1.53$\mu$m. We think that the mechanism of the reduction in propagation loss during the heat treatment is the following: 1) The hydrogen bonding in waveguide layer, which causes absorption loss, is dissociated and diffused out. 2) The roughness of the interface and the micro-structure of the waveguide layer is removed. 3) The irregularities in the cross-sectional shape of the waveguide which was induced during the lithographic process were disappeared by flowing of the waveguide core.

  • PDF

Basic characteristics of an indented cylinder broken rice separator (원통형 홈 선별기의 쇄미선별 특성)

  • 순영석;김명호;박승제;이종호
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.282-288
    • /
    • 2002
  • 본 연구는 상업용 규모의 쇄미선별공정에 사용할 수 있는 파이로트 규모 원통형 홈 선별기 시작기의 설계 및 제작에 필요한 기초 연구로서, 실험실용 원통형 홈 선별기를 이용하여 쇄미선별 실험을 실시하였다. 원통 회전속도, trough각도, indent 크기와 형상, 공급량을 요인으로 하여 완전립의 수거율과 순도, 쇄립의 수거율과 순도 및 선별효율을 조사하였다. 수행한 연구결과를 요약하면 다음과 같다. 1. 선별효율에 대한 원통 회전속도와 trough각도의 단독효과 및 교호작용은 1% 수준에서 유의성이 인정되었다. 원통 회전속도가 커지면trough각도 역시 그에 따라 적절히 증가시켜야만 선별효율의 저하가 방지되는 것으로 나타났다. 2. 최고 선별효율 값은 홈의 모양과 크기, 그리고 공급량에 관계없이 낮은 회전속도 (17rpm)와 중간 trough각도 (37.5$^{\circ}$또는 60$^{\circ}$)가 조합된 처리에서 나타났으며, 60~70% 범위의 높은 값을 보였다. 선별효율에 관한 원통 회전속도와 trough각도의 최적 조합은 17rpm, 37.5$^{\circ}$라고 판단된다. 3. 말발굽형 홈과 반구형 홈 간 선별효율의 차이는 없었다. 따라서, 실제 상업용 규모의 원통형 홈 쇄미선별기 개발에 있어서는 제작이 쉽고 유지.보수가 간편한 반구형 홈을 채택하는 것이 바람직할 것으로 생각된다. 길이 2.5mm이하의 미립인 쇄미의 선별에 사용할 홈의 크기는 2.5mm 보다는 약간 큰 3.0mm 정도가 되어야만 할 것으로 판단된다. 4. 공급량에 따른 선별효율의 차이는 1% 수준에서 유의성이 인정되었으며, 공급량이 작았을 때 전반적으로 선별효율이 높았다.타리 시프터를 채택, 사용하고 있었으며, 로타리시프터 사용상의 문제는 회전몸체를 지지하는 rod spring의 파손 등 구조와 관련된 것이었다. 로타리 시프터에 의한 쇄립의 선별과 제거정도는 만족할 만한 수준은 아니었다. 4. 국내 유통백미 완전립의 길이, 폭, 두께는 각각 5.02mm, 2.93mm, 2.03mm이었으며, 산물밀도와 천립중은 각각 745.3kg/m3 및 20.46g이었다. 5. RPC 백미제품의 품질경쟁력 향상을 유도하고자 현행 쇄미의 정의와 기준을 보다 강화하여 다음과 같은 쇄미 기준과 계급을 설정, 제시하였다. "완전립" - 길이가 3.75mm이상인 미립 "준완전립" - 길이가 2.5∼3.75mm인 미립 "쇄미" - 길이가 1.75∼2.5 mm인 미립 "이물" - 길이가 1.75mm이하인 미립.볼 때 상토 종자혼합비 6 : 1, 성형롤 회전속도 약 7 rpm으로 판단되며, 이 때 제조능력은 시간당 약 65 Kg(펠렛종자 약 39,000 개), 성형률 약 87 %, 종자손실률은 약 30 %, 펠렛종자 내 평균 종자수는 약 5.5 개, 완전 벼 종자 3개 이상 포함 펠렛종자 비율은 약 100 %가 될 것으로 보인다. 세포의 Androgen 생성을 촉진시키는 역할이 있는 것으로 보여진다 따라서 옻나무 유래 F는 포유동물의 생식기능에 중요하게 작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간

  • PDF

Assessment of Field Application of Contaminated Sediment Removal Efficiency Using PVDF Combined Hybrid Tunnel Drainage (PVDF(Polyvinylidene Fluoride) 필름형 트랜스듀서 하이브리드 터널배수재에 대한 오염퇴적물 제거효율의 현장 적용성 평가)

  • Xin, Zhen-Hua;Moon, Jun-Ho;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.513-519
    • /
    • 2019
  • Typically, contaminated sediments cause clogging of the drain pipe, which increases the residual water pressure in the drain pipe; this study constructed a system for improving drainage efficiency of tunnels by reducing physical and chemical obstructions through ultrasonic energy generated by a PVDF film. The developed hybrid drainage system utilized a PVDF material film fused with an existing drainage tunnel and maintenance system resulting in the ability to initialize the reverse piezoelectric effect, which was evaluated through an on site application. In order to investigate the maintenance performance of the tunnel drainage system, contaminated sediments were simulated in a drainage pipe to test the effect of ultrasonic conditions on drainage efficiency in the laboratory. As a result of applying the developed portable equipment, the ultrasonic energy was generated for about 20 minutes resulting in a reduction of 74.62% of the contaminated sediments and improving drainage efficiency. From the tunnel, acoustic pressure measurements were taken to calculate the response rate while taking into account the laboratory results. In addition, PVDF film was attached to the transverse and longitudinal side of the drainage pipes where contaminated sediments occur most often in the field tunnel. these calculations show contaminant removal was 90% effective.

Lifetime Reliability Based Life-Cycle Cost-Effective Optimum Design of Steel Bridges (생애 신뢰성에 기초한 강교의 LCC최적설계)

  • Lee, Kwang Min;Cho, Hyo Nam;Cha, CheolJun;Kim, Seong Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.75-89
    • /
    • 2006
  • This paper presents a practical and realistic Life-Cycle Cost (LCC) optimum design methodology of steel bridges considering time effect of bridge reliability under environmental stressors such as corrosion and heavy truck traffics. The LCC functions considered in the LCC optimization consist of initial cost, expected life-cycle maintenance cost and expected life-cycle rehabilitation costs including repair/replacement costs, loss of contents or fatality and injury losses, road user costs, and indirect socio-economic losses. For the assessment of the life-cycle rehabilitation costs, the annual probability of failure which depends upon the prior and updated load and resistance histories should be accounted for. For the purpose, Nowak live load model and a modified corrosion propagation model considering corrosion initiation, corrosion rate, and repainting effect are adopted in this study. The proposed methodology is applied to the LCC optimum design problem of an actual steel box girder bridge with 3 continuous spans (40 m+50 m+40 m=130 m), and various sensitivity analyses of types of steel, local corrosion environments, average daily traffic volume, and discount rates are performed to investigate the effects of various design parameters and conditions on the LCC-effectiveness. From the numerical investigation, it has been observed that local corrosion environments and the number of truck traffics significantly influence the LCC-effective optimum design of steel bridges, and thus realized that these conditions should be considered as crucial parameters for the optimum LCC-effective design.

A Study on the Seawater Filtration Characteristics of Single and Dual-filter Layer Well by Field Test (현장실증시험에 의한 단일 및 이중필터층 우물의 해수 여과 특성 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Kang, Byeong-Cheon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.51-68
    • /
    • 2019
  • This study performs to evaluate adaptability of seashore filtering type seawater-intake which adapts dua1 filter well alternative for direct seawater-intake. This study varies filter condition of seashore free surface aquifer which is composed of sand layer then installs real size dual filter well and single filter well to evaluate water permeability and proper pumping amount according to filter condition. According to result of step aquifer test, it is analysed that 110.3% synergy effect of water permeability coefficient is happened compare to single filter since dual filter well has better improvement. dual filter has higher water permeability coefficient compare to same pumping amount, this means dual filter has more improved water permeability than single filter. According to analysis result of continuous aquifer test, it is evaluated that dual filter well (SD1200) has higher water permeability than single filter well (SS800) by analysis of water permeability coefficient using monitoring well and gauging well, it is also analysed dual filter has 110.7% synergy effect of water permeability coefficient. As a evaluation result of pumping amount according to analysis of water level dropping rate, it is analysed that dual filter well increased 122.8% pumping amount compare to single filter well when water level dropping is 2.0 m. As a result of calculating proper pumping amount using water level dropping rate, it is analysed that dual filter well shows 136.0% higher pumping amount compare to single filter well. It is evaluated that proper pumping amount has 122.8~160% improvement compare to single filter, pumping amount improvement rate is 139.6% compare to averaged single filter. In other words, about 40% water intake efficiency can be improved by just installation of dual filter compare to normal well. Proper pumping amount of dual filter well using inflection point is 2843.3 L/min and it is evaluated that daily seawater intake amount is about $4,100m^3/day$ (${\fallingdotseq}4094.3m^3/day$) in one hole of dual filter well. Since it is possible to intake plenty of water in one hole, higher adaptability is anticipated. In case of intaking seawater using dual filter well, no worries regarding damages on facilities caused by natural disaster such as severe weather or typhoon, improvement of pollution is anticipated due to seashore sand layer acts like filter. Therefore, It can be alternative of environmental issue for existing seawater intake technique, can save maintenance expenses related to installation fee or damages and has excellent adaptability in economic aspect. The result of this study will be utilized as a basic data of site demonstration test for adaptation of riverside filtered water of upcoming dual filter well and this study is also anticipated to present standard of well design and construction related to riverside filter and seashore filter technique.

Strategies of Car-Ferry Shipping Companies According to the Korea-China Free Trade Agreement (한·중 FTA 체결에 따른 수도권항만 카페리선사의 발전방안)

  • Park, Sung-Eun;Ahn, Seung-Bum
    • Journal of Korea Port Economic Association
    • /
    • v.34 no.1
    • /
    • pp.111-132
    • /
    • 2018
  • As China continues to evolve as a major economic power and the Free Trade Agreement (FTA) between the Republic of Korea and China was ratified on June 1, 2015, market volume between the two countries is expected to grow more rapidly. This study aims on improving the efficiency of car-ferry lines. We conducted two surveys- for shippers and forwarders of car-ferry companies, and container liners. The study analyzes the decision factors for delivery companies and their importance for shippers and forwarders of car-ferry companies and container liners. Based on analysis of prior studies on the competition for car-ferry companies and liners, three primary variables are selected-promptness, economics, and safety. The promptness variable consists of shipping time, loading/unloading time, and customs clearing time. The economic variable consists of marine transportation cost from a domestic harbor to China, loading/unloading cost in the harbor, and overland transport cost from the harbor to shippers inland. Finally, the safety variable consists of cargo damage rates, safety facilities, such as lashing and shoring, and punctuality of transportation time. The survey and AHP results show that the promptness, safety, and economics factors are 0.549, 0.309, and 0.142 in the shipper groups of car-ferry companies' category, respectively. It indicates that there is considerable difference in the importance of each factor. In contrast, the factors are 0.350, 0.348, and 0.302 in the forwarders category, which suggests that there is little difference in each factor's importance. As for shippers and forwarders of liners, the importance of each factor is found to be in the following order: economics, safety, and promptness.

Mechanical Property Evaluation of Dielectric Thin Films for Flexible Displays using Organic Nano-Support-Layer (유기 나노 보강층을 활용한 유연 디스플레이용 절연막의 기계적 물성 평가)

  • Oh, Seung Jin;Ma, Boo Soo;Yang, Chanhee;Song, Myoung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.33-38
    • /
    • 2021
  • Recently, rollable and foldable displays are attracting great attention in the flexible display market due to their excellent form factor. To predict and prevent the mechanical failure of the display panels, it is essential to accurately understand the mechanical properties of brittle SiNx thin films, which have been used as an insulating film in flexible displays. In this study, tensile properties of the ~130 nm- and ~320 nm-thick SiNx thin films were successfully measured by coating a ~190 nm-thick organic nano-support-layer (PMMA, PS, P3HT) on the fragile SiNx thin films and stretching the films as a bilayer state. Young's modulus values of the ~130 nm and ~320 nm SiNx thin films fabricated through the controlled chamber pressure and deposition power (A: 1250 mTorr, 450 W/B: 1000 mTorr, 600 W/C: 750 mTorr, 700 W) were calculated as A: 76.6±3.5, B: 85.8±4.6, C: 117.4±6.5 GPa and A: 100.1±12.9, B: 117.9±9.7, C: 159.6 GPa, respectively. As a result, Young's modulus of ~320 nm SiNx thin films fabricated through the same deposition condition increased compared to the ~130 nm SiNx thin films. The tensile testing method using the organic nano-support-layer was effective in the precise measurement of the mechanical properties of the brittle thin films. The method developed in this study can contribute to the robust design of the rollable and foldable displays by enabling quantitative measurement of mechanical properties of fragile thin films for flexible displays.

Numerical Prediction for Fluidized Bed Chlorination Reaction of Ilmenite Ore (일메나이트광의 유동층 염화반응에 대한 수치적 예측)

  • Chung, Dong-Kyu;Jung, Eun-Jin;Lee, Mi Sun;Kim, Jinyoung;Song, Duk-Yong
    • Clean Technology
    • /
    • v.25 no.2
    • /
    • pp.107-113
    • /
    • 2019
  • Numerical model that considered the shrinking core model and elutriation and degradation of particles was developed to predict selective chlorination of ilmenite and carbo-chlorination of $TiO_2$ in a two stage fluidized bed chlorination furnace. It is possible to analyze the fluidized bed chlorination reaction to be able to reflect particle distribution for mass balances and the chlorination reaction. The numerical model showed an accuracy with error less than 6% compared with fluidized bed experiments. The chlorination degree with particle size change was greater with a smaller particle size, and there was a 100 min difference to obtain a chlorination degree of 1 between $75{\mu}m$ and $275{\mu}m$. This was not shown to such a great extent with variation of temperature ($800{\sim}1000^{\circ}C$), and there was only a 10 min difference to obtain a chlorination degree of 0.9. In the first selective chlorination process, the mass reduction rate approached to the theoretical value of 0.4735 after 180 min, and chlorination changed the Fe component into $FeCl_2$ or $FeCl_3$ and showed nearly 1. In the second carbo-chlorination process, the chlorination degree of $TiO_2$ approached 0.98 and the mass fraction reached 0.02 with conversion into $TiCl_4$. In the first selective chlorination process, 98% of $TiO_2$ was produced at 180 min, and this was changed into 99% of $TiCl_4$ after an additional 90 min. Also the mass reduction rate of $TiO_2$ was reduced to 99% in the second continuous carbo-chlorination process.

Temperature Sensitivity Analysis of TDR Moisture Content Sensor for Road Pavement (도로하부 함수비 계측을 위한 TDR 방식 함수비 센서 온도 민감도 분석)

  • Cho, Myunghwan;Lee, Yoonhan;Kim, Nakseok;Jee, Keehwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.329-336
    • /
    • 2013
  • The infrastructure of flexible pavement is composed of aggregate subbase, anti-frost layer, and subgrade. In particular, the subgrade performance is affected by climates such as frost action and precipitation. The method of TDR(Time Domain Reflectometry) sensors to measure moisture contents in subgrade layer has been used in the research. Due to the TDR method using dielectric permitivity of soil and water, the sensors can be affected by the low subgrade temperatures. The air temperatures frequently drops below $-20^{\circ}C$ in the winter in Korea. As a result, it is necessary to estimate the accuracy of the TDR moisture sensors in the range of below zero temperatures. In this study, the subgrade temperatures of lower than $-2^{\circ}C$ were extended to evaluate temperature sensitivity of the TDR moisture sensors. The test results revealed that the moisture contents around the sensors were reduced while those of the upper part of specimen showed a tendency to increase as the specimen surface temperature drops below zero under the volumetric moisture contents(VMC) of 20% and 30%. However, the impact of temperature on the function of the sensor at lower water contents was found to be negligible if any.

Uncertainty Assessment of CANDU Void Reactivity using MCNP-4C with ENDF/B-VII(I) (ENDF/B-VII기반 MCNP-4C를 이용한 CANDU-6 기포반응도 불확실성 평가(I))

  • Hong, S.T.;Kwon, T.A.;Lee, Y.J.;Oh, S.K.;Lee, S.K.;Kim, M.W.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.69-75
    • /
    • 2008
  • 기포반응도는 월성발전소를 비롯한 CANDU형 원자로의 주된 안전성 쟁점사안으로 끊임없이 논의되어 왔다. 이는 설계기준사고가 노심에서 열에너지 불균형이 원인이 되어 기준이상의 핵연료 파손과 방사성물질 누출로 발전할 위험이 있는 사건들로 정의될 때, 사건 진행 과정에 기포반응도 증가는 조기에 운전중단을 실패할 경우 출력폭주로 이어지므로 사건의 결말이 중대사고로 전환될 위험이 크기 때문이다. 본 연구는 공개된 최신 핵자료인 ENDF/B-VII.0를 NJOY.99로 처리한 연속에너지 반응단면적 라이브러리를 구축하고 MCNP-4C에 접속하여 37봉 천연우라늄 핵연료다발의 표준노심격자에 대한 기포반응도를 시뮬레이션하여, 지금까지 각종문헌에 제시된 값들과 비교, 종합하므로 내제된 불확실성을 추정하는 내용이다. ENDF/B-VII.0 기반 MCNP-4C의 CANDU 노심격자 모델은 동일한 핵자료와 핵종농도를 사용한 WIMS-IAEA 모델과 비교할 때, 초기 노심의 임계도 오차 약 3.51mk가 연소 진행에 따라 $7.5\times10^{-4}mk$/MWD/teU의 비율로 감소하는 것으로 나타났다. 또한 MCNP-4C 예측기포반응도는 초기노심에서 기포율 50% 및 100%에 대해 각각 8.38 및 15.96mk, 평형노심에서 7.68 및 14.72mk로 계산된다. 이는 월성 2, 3, 4 FSAR의 초기노심 및 평형노심에서 100% 기포상태에 대한 값, 약15.0 및 10.6mk와 비교할 때, 초기노심은 약 1.0mk 평형노심은 약4, 1mk 보수적이지만, 다른 연구결과들과는 최대오차 ${\pm}1{\sim}2mk$ 이내에서 잘 일치하는 것으로 평가되었다. 본 연구는 CANDU 노심의 기포반응도 불확실성 요인의 규명 및 영향평가를 위한 노력의 일부로서 앞으로 감속재의 붕산농도 변화, 감속재 및 냉각재의 중수 순도 변화, 기기노화에 의한 격자 구조 및 물성 변화, 중성자속 및 출력 분포 불균형, 반응도조절장치의 위치, 등 주요 설계변수의 변화에 대한 반응도영향 분석연구를 계속할 계획이다.

  • PDF