• Title/Summary/Keyword: 파괴기준

Search Result 989, Processing Time 0.025 seconds

HYDROLYTIC DEGRADATION OF DENIAL COMPOSITE RESINS (수종 치과용 복합레진의 가수분해)

  • Yang, Kyu-Ho;Kim, Jung-Ran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.370-378
    • /
    • 2000
  • The composite restorative resins have their insufficient resistance to wear. The subsurface degradation within the restoration is considered to be associated with wear. The aim of this study was to evaluate the resistance to degradation of six commercial composite resins in an alkaline solution. The brands studied were Clearfil APX(Kuraray), Heliomolar(Vivadent), Surefil(Dentsply), TPH(Dentsply), Tetric Ceram(Vivadent), and Z100(3M). Preweighed discs of each brand were exposed 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCL, washed with water and dried to constant mass at $60^{\circ}C$. Resistance to degradation was evaluated on the basis of the following parameters: (a) mass loss(%) - determined from pre-and post-exposure specimen weights; (b) Si loss (ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth$({\mu}m)$ - measured microscopically (SEM) from polished circular sections of exposed specimens. The results were as follows: 1. The mass loss was in descending order by Z100, TC H, S, CL, TPH and in the range of $0.45\sim3.64%$ 2. The degradation layer depth was in descending order by H, Z100, S, TC, TPH, CL and in the range of $10.85\sim73.38{\mu}m$ 3. For the Si concentration, Z100 was the highest of all 4. The highly significant correlation(r=0.81, p<0.05) was observed between mass loss and degradation depth. 5. Under scanning electronmicroscopy, the degradation of connection between resin matrix and fillers was observed 2 weeks after soaking in NaOH solution.

  • PDF

Evaluation of Design Temperature for Asphalt Concrete in South Korea (남한의 아스팔트 콘크리트 설계온도 추정에 관한 연구)

  • Lee, Kwang Ho;Kim, Soo Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.77-85
    • /
    • 1992
  • Layer material properties of asphalt concrete changes with climatic conditions. Pavement design and analysis should be performed in the representative climatic condition that gives standard physical properties of pavement layer materials. In this study, an evaluation procedure of pavement design temperature is proposed and programed based on damage effect analysis using fatigue failure criterion. Three regions, Seoul, Daegeon, and Pusan, are chosen to obtain the representative climatic data of South Korea. Domestic pavement design temperature is developed by applying the proposed algorithm to 6 domestic pavement section models with the respective regional climatic data. Asphalt concrete pavement failure criterion is also proposed for the condition of developed domestic pavement design temperature. The design temperature for the region of South Korea is estimated as $l7^{\circ}C$, which is converted to $23.6^{\circ}C$ for the AC surface layer temperature. It is found that the procedure to determine design properties of AC surface layer material at $20^{\circ}C$ gives overestimated results of AC moduli for the domestic pavement system. From the comparison study, it is also found that the estimated pavement design temperature is similar to the result of SHELL Design Chart.

  • PDF

Investigation of Lichen Species as a Biomonitor of Atmospheric Ozone in 'Backwoon' Mountain, Korea (백운산(白雲山) 서식(棲息) 지의류(地衣類)를 이용(利用)한 오존 민감성(敏感性) 지표종(地表種) 선발(選拔))

  • Hur, Jae-Seoun;Kim, Pan-Gi
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.1
    • /
    • pp.65-76
    • /
    • 2000
  • Lichen flora of 'Backwoon' mountain, Korea, was investigated during the summer of 1998 and 1999 to screen out lichen species which can be used as a biomonitor for atmospheric ozone. The identified foliose or fructicose lichens in the area were classified into 9 families, 20 genera and 34 species. The dominant lichen species in the area were found to be Leptogium sp., Parmelia sp., Parmotrema sp., Phaeophyscia sp. and Cladonia sp. It was also found that lichen species showing a wide range of sensitiveness to air pollution were distributed in 'Backwoon' mountain. The Parmotrema austrosinense, P. tinctorum, Certrelia braunsiana and Ramalina yasudae collected in the area were exposed to ozone at the level of 200ppb, 8hr/day in controlled growth chamber for 2 weeks. Malondialdehyde(MDA), hydroperoxy conjugated dienes(HPCD), soluble protein content and OD435nm/OD415nm ratio for phaeophytinization of chlorophyll were measured and a pollution index(PI) was calculated for each lichen. Ozone exposure severely damaged to the lichens in the order of P. austrosinense>P. tinctorum>C. braunsiana>R. yasudae. P. austrosinens easily identified and widely distributed in Korea is likely to be a very useful biomonitor of air pollution, especially for ozone. These results indicate that Korean lichen species can be used as a biomonitor for air pollution to evaluate air quality contaminated with ozone.

  • PDF

Evaluation of Shear Strength of Concrete Layers with Different Strength considering Interfacial Indentation (이종강도 부재간 연결면 조건에 따른 전단강도 평가)

  • Kang, Jae-Yoon;Park, Jong-Sup;Jung, Woo-Tai;Keum, Moon-Seoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.449-455
    • /
    • 2016
  • This study is a part of research to develop a steel-concrete hybrid girder using ultra high-performance concrete with a compressive strength of 80 MPa. To this end, the Eurocode design formula for the shear resistance developed in a concrete-to-concrete interface was examined for the interface between concrete layers of different strengths. To examine the effect of the surface roughness on the shear resistance, a push-out test was conducted on specimens while considering the parameters of the Eurocode design equation. The actual behavior was evaluated with respect to the compressive strength of the concrete, the reinforcement ratio of the shear rebar, and the interfacial surface condition. The specimen with a rough interface shows 20-50% higher shear strength than that estimated by the design equation. In the case of failure mode, abrupt failure tends to occur at the interface of the concrete layer for the specimen with a low reinforcement ratio. It is expected that the shear strength of the concrete layer will increase according to the strength differential in the concrete layers.

Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch (프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가)

  • Ahn, Jin-Hee;Yim, Hong Jae;Bang, Jin Soo;Jeon, Seok Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Precast concrete segment arch system has an economic and construct ability that combined with advantage of precast concrete and arch behavior. A precast concrete segment arch system with outrigger is consisted of segmented precast panels, a steel outrigger rib, and V-strip to connect precast panels with a steel outrigger rib and cast-in-place anchors in precast panels to connect V-strip should have sufficient pull-out capacity to form its arch shape by site lifting for assembled precast panels and outriggers. However, it is difficult to secure its embedment depth due to the relatively shallow thickness of precast panel. It can be also occurred that flexure deformation of precast panels caused by its pull-out behaviors. In this study, pull-out capacity of cast-in-place anchor was examined for construction of precast concrete segment arch system with outriggers. Therefore, a total of 24 precast panel specimens were fabricated to examine pull-out capacities of cast-in-place anchor in precast panels, and installation depth of anchors, diameter of anchors and wire mesh effects for the precast panel were examined. From this pull-out tests, its pull-out capacities and failure modes were evaluated and the type of the cast-in-place anchor applicable to the precast concrete segment panel arch system with outriggers was determined from comparison of the design specification values.

Fatigue Characteristics according to the Shape of Cover Plate in Steel Plate Girders (강판형의 덮개판 형상에 따른 피로특성)

  • Jung, Young Hwa;Hong, Sung Wook;Kim, Ik Gyeom;Jung, Jin Suck
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.111-122
    • /
    • 2000
  • In this study, A series of fatigue tests have been performed on the fillet welded joints of cover plates in steel plate girders in order to quantitatively assess the fatigue characteristics according to the shapes of cover plates. From the results of fatigue tests, it has been shown that the fatigue strengths were slightly different according to their shapes, but satisfied the fatigue design curves in Korea and other countries. Also, from the results of beachmark tests, it has been confirmed that the points of fatigue crack initiation were closely related to the shapes of weld bead toes, and fatigue cracks simultaneously initiated from several points in weld bead toes have been grown as semi-elliptical surface cracks, and these cracks have been coalesced each other, and grown as through thickness cracks, and finally reached to fracture. Besides, from the results of fracture mechanics approaches, stress gradient factors were the most dominant factors among crack correction factors obtained from the existing equations and finite element analysis, and the fatigue life on fillet welded joints of cover plates could be estimated using the relations between fatigue crack growth rate and stress intensity factor range obtained from finite element analysis.

  • PDF

A Study on the Fatigue Characteristics and Life Prediction of the Tire Sidewall Rubber (타이어 사이드월 고무의 피로특성 및 수명예측에 관한 연구)

  • Moon, Byungwoo;Kim, Yongseok;Jun, Namgyu;Koo, Jae-Mean;Seok, Chang-Sung;Hong, Ui Seok;Oh, Min Kyeong;Kim, Seong Rae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.629-634
    • /
    • 2017
  • In the case of the UHP (Ultra high performance) tire that the demand has increased rapidly, compared with the commonly used tire, severe deformation has been observed because of the low aspect ratio. When repeated deformations are applied to the sidewall rubber, accumulated fatigue damage may cause fatigue failure. Thus, the evaluation of the durability of the tire sidewall rubber has become a very important issue to prevent accidents that occur while the vehicle is running. However, the research and design criteria for the durability performance of the tire sidewall rubber hardly exist. In this study, we suggest a lifetime prediction formula using strain energy density obtained by performing tensile tests and fatigue tests on two different kinds of the tire sidewall compounds. Additionally, the applicability of our findings for low fuel consumption tires was reviewed by converting the fatigue life of the sidewall rubber into the expected mileage of the tire.

Strength Properties of GFRP Reinforced Glulam Beams Bonded with Polyvinyl Acetate-Based Emulsion Adhesive (초산비닐수지계 접착제를 사용한 유리섬유강화플라스틱 복합집성재의 강도 성능 평가)

  • Park, Jun-Chul;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.19-25
    • /
    • 2008
  • This study was carried out to investigate the bending strength properties of the unreinforced glulam beams and the GFRP laminated glulam beams according to the volume ratio of GFRP. The 7-layer glulam beams ($10cm(b){\times}14cm(h){\times}180cm(l)$) were manufactured, using Larch (Larix kaempferi Carr.) laminae ($2cm(h){\times}10cm(b){\times}360cm(l)$), which were dried to the moisture content of 8% and specific gravity of 0.54. GPRP of 0.1 and 0.3 cm was reinforced between the outmost layer of bottom and next layer. When the glulam beams were reinforced with GFRP at the volume ratio of 0.7% and 2.1%, respectively, the bending strength was increased by 12% and 28%, respectively, in the reinforced beams than in control glulam beams. Also, the GFRP reinforced layer of the glulam beams with GFRP laminations blocked the progression of rupture, and the unbroken part held about 90% of the bending strength. In the results of glue joints test, the block shear strength is higher than $7.1N/mm^2$, the standard of KS F3021, and in the result of delamination, the adhesive strength is good as the water soaking and boiling delamination was less than 5%.

Development of small constructed wetland for urban and roadside areas (도시 및 도로 조경공간을 활용한 소규모 인공습지 조성 기술)

  • Kang, Chang-Guk;Maniquiz, Marla C.;Son, Young-Gyu;Cho, Hye-Jin;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.231-242
    • /
    • 2011
  • Recently, the green spaces in the urban areas were greatly reduced due to urbanization and industrialization. As urban structures such as roads and buildings are built, the amount of impervious area within a watershed increases. High impervious surfaces are the common causes of high runoff volumes as the soil infiltration capacity decreases and the volume and rate of runoff increase thereby decreasing the groundwater recharge. These effects are causing many environmental problems, such as floods and droughts, climate change, heat island phenomenon, drying streams, etc. Most cities attempted to reduce sewer overflows by separating combined sewers, expanding treatment capacity or storage within the sewer system, or by replacing broken or decaying pipes. However, these practices can be enormously expensive than combined sewer overflows. Therefore, in order to improve these practices, alternative methods should be undertaken. A new approach termed as "Low Impact Development (LID)" technology is currently applied in developed countries around the world. The purpose of this study was to effectively manage runoff by adopting the LID techniques. Small Constructed Wetland(Horizontal Subsurface Flow, HSSF) Pilot-scale reactors were made in which monitoring and experiments were performed to investigate the efficiency of the system in removing pollutants from runoff. Based on the results of the Pilot-plant experiments, TSS, $COD_{Cr}$, TN, TP, Total Pb removal efficiency were 95, 82, 35, 91 and 57%, respectively. Most of the pollutants were reduced after passing the settling tank and the vertical filter media. The results of this study can contribute to the conservation of aquatic ecosystems and restoration of natural water cycle in the urban areas.

Ecosystem Risk Assessment Using the Indicator Species (지표종을 이용한 생태계 위해성평가)

  • Chang, Jin-Soo;Kim, Kyoung-Woong
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.1
    • /
    • pp.103-115
    • /
    • 2007
  • Risk assessment by living indicator species provides the information about the ecosystem disturbance, disapperance of symbiosis and change of living group. In the initial stage of this kind research, the degree of contamination was reported using the level of simple number, but simple number may not represent the risk itself which can be casued in the living organisms. Risk assessment using various indicator species overcomes these limitations and can be expanded to the DNA level. In many developed counties, the government has supervised the researches about the indicator species for the monitoring and its application to ecosystem restoration. Several living indicator species found in the vicinity of the abandoned Au mines such as fern, earthworm, bacteria, rhizosphere-rhizoplane, salamamdor and DNA change of these species are described in this paper.