• Title/Summary/Keyword: 티타늄

Search Result 1,160, Processing Time 0.024 seconds

A study on the Functional Properties of Polyester Fiber Treated Titanium Dioxide Photocatalyst (이산화티타늄 광촉매를 처리한 Polyester 섬유의 기능성 연구)

  • Choi, Sei Young
    • Elastomers and Composites
    • /
    • v.49 no.4
    • /
    • pp.336-340
    • /
    • 2014
  • The functionality such as deodorant, antibacterial, ultraviolet shielding of titanium dioxide self-actuated photocatalyst $Weltouch^{TM}$ treated polyester fiber was characterized in conditions without light. The deodorizing capacity was maintained more than 97% reduction irrespective of before washing and after 20 times repeated washing, and antimicrobial capacity was also retained more than 99.9% reduction. Titanium dioxide self-actuated photocatalyst was still maintained to the surface of polyester fiber without separation even after 20 times repeated washing. According to washing durability of polyester fiber, the reduction effect for ammonia was still retained even after 20 times repeated washing as much as before washing. The ultraviolet shielding capacity was still maintained at least 83% irrespective of before washing and 20 times repeated washing.

Enhanced Fluorescence from Silk Protein with TiO2 Scatters (산화티타늄 나노 입자에 의한 실크 단백질 형광 증폭 연구)

  • Rakesh Kumar Jha;Sunghwan Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.1
    • /
    • pp.30-34
    • /
    • 2024
  • We report a purely protein-based platform for green fluorescence by mixing silk protein with green fluorescence protein, and also report its enhancement by the incorporation of TiO2 nanoparticles. The TiO2 nanoparticles employed have diameters of 100 and 300 nm, with a significant increase in fluorescence (by a factor of 7.5) observed when introducing 300-nm TiO2 nanoparticles. Furthermore, an increase in particle distribution density is found to enhance fluorescence amplification. These research findings suggest that protein-based fluorescent films can be enhanced by the characteristics of nanoparticles, opening up new possibilities in the fields of optics and fluorescence applications.

The Effect of Titanium on the Castability of Cobalt-Chrome Alloy (코발트 크롬 합금의 주조성에 미치는 타이타늄의 효과)

  • Ryu, Su-Kyoung;Chung, Hee-Jeong;Vang, Mong-Sook;Yang, Hong-So;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose of this experiment is to evaluate the effect of titanium on the castability when the titanium is added to the Co-Cr alloy. Raw materials Cobalt, Chrome, Molybdenum, Silicon, Manganase, Carbon, Nitrogen, Titanium were weighted and prepared. $Biosil^F$ (Degudent, Germany) was the control group. To the experimental group, different weight percent of titanium was added from 1 wt% to 4 wt%. The wax pattern is $30{\times}40$ cm in size, rectangular in shape and has total of 160 grids. Centrifugal machine (Neutrodyne Easy Ti: Manfredy) was used for casting. For evaluation of the castability, the number of complete grids was counted by visual inspection and X-ray inspection. The test showed similar castability with the control group in the titanium addition of 1 wt% to 3 wt%. The titanium addition of 4 wt% showed poor result. With titanium lower than 4 wt%, the experiment metals showed proper castability with high expectation of successful clinical use.

Effects of anaerobic sealing agents on preload maintenance of screw-retained implant prosthesis with surface of screws (임플란트 보철물 나사의 전하중 유지에 나사 표면에 따른 혐기성 나사 고정제의 효과)

  • Ryu, Seung-Beom;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.103-109
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the preload maintenance of the retaining screw when using anaerobic sealing agents in implant fixture and abutment components. Specifically, the study examines the effects of anaerobic sealing agents on different types of screws. Materials and methods: External hexagon implants made of titanium and anti-rotational abutments were used. Titanium abutment screws and ebony abutment screws from the same manufacturer were used. The experiment was divided into four groups (n = 10 in each group). In the control group, no sealing agent was used at the implant fixture and abutment screw interface. All abutment screws were tightened according to the manufacturer's recommended torque (30 N.cm). After 24 hours, the removal torque (detorque) of each screw was measured using a digital torque gauge device. The data were analyzed by two-way ANOVA test according to normality distribution satisfaction. Results: Looking at the results for each group, titanium screws and no treatment showed detorque values of 20.3 ± 1.6 N.cm. titanium screws and applied anaerobic sealing agent showed detorque values of 32.4 ± 6.7 N.cm. Ebony screws and no treatment showed detorque values of 20.2 ± 1.5 N.cm. ebony screws and applied anaerobic sealing agent showed detorque values of 30.4 ± 4.5 N.cm. Conclusion: The detorque value was higher in the case of using anaerobic sealing agents in both the titanium screw and ebony screw groups. But there was no difference between the two screws.

The Impact of Signal Intensity and Image Distortion Magnetic Resonance Imaging in the Orthopedic Prosthetic Metal (자기공명영상에서 정형보철 금속이 신호강도와 영상왜곡에 미치는 영향)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.321-326
    • /
    • 2012
  • Used as an ingredient in the hospital for orthopedic prosthetic stainless and titanium metal the same size as on the MRI diagnostic value of imaging were compared. Center of images, background high band portion of the video signal is converted into a weighted intensity values Normal images and compared. The area of normal slice and also the distortion of images and cross-sectional imaging of a range of quantitative and sagittal planes were compared. As a result, the periphery high band signal intensity values of Stainless video phantom 2, pig bone 1.8, Titanium imaging of phantom 1.7 has higher value than Normal video pig bone 1.3 times the signal strength rivers. MRI distortion of the shape and the distortions of the range, if the cross-sectional area compared to Normal Slice Stainless case of phantom 65.8 %, pig bone 61.5 %, Titanium distortion phantom 23.1 %, pig bone 38.5 % of the range of community found. In this experiment, as a result, MRI was found to be Titanium more diagnostic value than the specimen with respect to the signal intensity weighted value and low distortion range, Stainless.

Comparative analysis of various corrosive environmental conditions for NiTi rotary files (니켈티타늄 파일의 부식에 영향을 미치는 다양한 환경 조건 비교)

  • Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.377-388
    • /
    • 2008
  • The aim of the present study is to compare the corrosion tendency using two kinds of NiTi files in the various environmental conditions through the visual examination and electrochemical analysis. ProTaper Universal S2, 21 mm (Dentsply Maillefer, Ballaigues, Switzerland) and Hero 642, 0.06 tapers, size 25, 21 mm (Micromega, Besancon, France) rotary instruments were tested. The instruments were randomly divided into eighteen groups (n = 5) by the immersion temperature, the type of solution, the brand of NiTi rotary instrument and the presence of mechanical loading. Each file was examined at various magnifications using Scanning Electron Microscope (JEOL, Akishima, Tokyo, Japan) equipped with energy dispersive X-ray microanalysis (EDX). EDX was used to determine the components of the endodontic file alloy in corroded and noncorroded areas. The corrosion resistance of unused and used NiTi files after repeated uses in the human teeth was evaluated electrochemically by potentiodynamic polarization test using a potentiostat (Applied Corrosion Monitoring, Cark-in-Cartmel, UK). Solution temperature and chloride ion concentration may affect on passivity of NiTi files. Under the conditions of this in vitro study, the corrosion resistance is slightly increased after clinical use.

STRESS DISTRIBUTION OF THREE NITI ROTARY FILES UNDER BENDING AND TORSIONAL CONDITIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS (세가지 니켈 티타늄 파일의 휨과 비틀림 조건에서의 응력 분포에 관한 3차원 유한요소 연구)

  • Kim, Tae-Oh;Lee, Chan-Joo;Kim, Byung-Min;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.323-331
    • /
    • 2008
  • Flexibility and fracture properties determine the performance of NiTi rotary instruments. The purpose of this study was to evaluate how geometrical differences between three NiTi instruments affect the deformation and stress distributions under bending and torsional conditions using finite element analysis. Three NiTi files (ProFile .06 / #30, F3 of ProTaper and ProTaper Universal) were scanned using a Micro-CT. The obtained structural geometries were meshed with linear, eight-noded hexahedral elements. The mechanical behavior (deformation and von Mises equivalent stress) of the three endodontic instruments were analyzed under four bending and rotational conditions using ABAQUS finite element analysis software. The nonlinear mechanical behavior of the NiTi was taken into account. The U-shaped cross sectional geometry of ProFile showed the highest flexibility of the three file models. The ProTaper, which has a convex triangular cross-section, was the most stiff file model. For the same deflection, the ProTaper required more force to reach the same deflection as the other models, and needed more torque than other models for the same amount of rotation. The highest von Mises stress value was found at the groove area in the cross-section of the ProTaper Universal. Under torsion, all files showed highest stresses at their groove area. The ProFile showed highest von Mises stress value under the same torsional moment while the ProTaper Universal showed the highest value under same rotational angle.

EFFECTS OF ANTICURVATURE FILING ON DANGER ZONE WIDTH IN CURVED ROOT CANALS (만곡된 근관 성형시 스테인레스 강 파일과 니켈 티타늄 파일의 anticurvature filing 영향)

  • Kim, Eui-Seong;Kim, Hyun-Jung;Seo, Deog-Gyu;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.232-239
    • /
    • 2009
  • The aim of this study was to compare the effects of anti curvature filing with stainless steel k-file versus nickel-titanium ProFile in the shaping of mesial root canals of extracted mandibular molars. A total of 60 canals from 30 mesial roots of mandibular molar teeth were randomly assigned to three groups with n=20 each. They were prepared with different instruments and methods: The first group with stainless steel k-file and circumferential filing. the second with precurved stainless steel k-file and anticurvature filing and the third with ProFile C06 taper) and anticurvature filing. Using a micro-computed tomography system (skyscan-1076, SKYSCAN, Antwerpen, Belgium), pre-and post-operative specimens were scanned. Subsequently, canal images were superimposed and changes in root dentin thickness were measured at distal side (danger zone) of the canal. The data was analyzed using a one-way ANOVA and the comparison of means was conducted using a post hoc multiple comparison Tukey test. There were significant differences in the change of root dentin thickness at the $7.5{\sim}8.5\;mm$ level between group 1 and 2, $3.5{\sim}6mm$ level between group 1 and 3 and $3.5{\sim}6mm$ level between group 2 and 3(n=20, P<0.05).

The effect of lubricants in removing smear layer on canal enlargement with engine-driven Ni-Ti file (엔진 구동형 니켈 티타늄 파일을 이용한 근관 확대 시 도말층 제거에 대한 윤활제의 영향)

  • Jeong-Beom Min;Young-Lin Cho;Ho-Keel Hwang
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.3
    • /
    • pp.206-214
    • /
    • 2001
  • 근관계의 완전한 충전을 위해 기계적인 근관 확대 및 화학적인 세척은 필수 불가결하다. 근관내 기구 조작 시 근관벽에는 무기물과 유기물로 구성된 도말층이 형성되는데, 이 층은 서서히 분해되어 충전재 주위에서 미세누출을 야기하고, 세균과 그 부산물이 이동할 수 있는 통로를 제공하기 때문에 제거되어야 한다. 현재 이러한 목적을 위해 다양한 기구들과 세척 용액들이 이용되고 있다. 최근에는 근관확대를 위해 엔진 구동형 니켈-티타늄 파일이 개발되어 임상에서 널리 사용되고 있으며, 이러한 엔진 구동형 파일을 사용할 때는 윤활제의 사용이 필수적이다. 현재 시판되고 있는 윤활제들에는 도말층 제거를 위한 EDTA가 함유되어 있다. 따라서, 본 연구의 목적은 엔진 구동형 니켈-티타늄 파일을 이용해 근관을 확대할 경우 이런 윤활제들의 도말층 제거 효과를 비교 평가하는 것이다. 본 실험에는 75개의 치아가 각각 15개씩 5개의 군으로 분류되어 사용되었다. 대조군은 윤활제를 사용하지 않은 경우이고, 실험 1군에서는 윤활제로 RC-PREP$^{TM}$이, 실험 2군에서는 Glyde$^{TM}$가 각각 사용되었고. 실험 3군은 RC-PREP$^{TM}$을 사용한 후 17% EDTA로 처리하였으며. 실험 4군은 Glyde$^{TM}$를 사용한 후 17% EDTA로 처리하였다. 처리된 시편을 절단한 후 주사전자현미경을 통해 시편의 근관의 중앙부와 치근단 부위를 관찰하여 얻어진 결과는 다음과 같다. 1. 대조군과 실험군의 비교시, 대조군에서 더 많은 양의 도말층이 관찰되었고, 이는 통계학적으로 유의성이 있었다 (p<0.01). 2. 윤활제의 종류에 따른 비교 시, Glyde$^{TM}$를 사용한 2군에서 RC-PREPTM을 사용한 1군 보다 더 적은 양의 도말층이 관찰되었지만, 이는 통계학적으로 유의성이 없었다. 3. 윤활제 사용과 EDTA 처리에 따른 효과 비교 시, EDTA로 처리한 3, 4군에서 윤활제만을 사용한 1, 2군 보다 더 적은 양의 도말층이 관찰되었으며, 이는 통계학적으로 유의성 이 있었다(P<0.01). 4. 치근 중앙부와 치근단 부위에서의 도말층 제거 효과 비교 시, 1, 2군에서는 치근 중앙부에서 더 적은 양의 도말층이 관찰되었고, 통계학적으로 유의성이 있었다(P<0.01). 3, 4군에서는 중앙부의 도말층이 더 적었지만 통계학적으로 유의성이 없었다. 이상으로부터 EDTA가 함유된 윤활제를 함께 사용하면서 엔진구동형 니켈-티타늄 파일로 근관확대 시, 근관벽에 형성된 도말층 제거에 대한 파일의 효능이 상승되었다. 그러나, 윤활제의 도말층 제거 효과는 17% EDTA용액으로 근관벽을 처리하는 것보다는 낮았다 따라서, 엔진구동형 니켈-티타늄 파일로 근관확대 시 EDTA가 함유된 윤활제를 함께 사용하는 것이 요구되고, 보다 완벽하게 도말층을 제거하기 위해서는 충전 전에 17% EDTA 용액으로 근관벽을 처리하는 것이 필요하다고 사료된다.

  • PDF

Inhibition of Osteoclast differentiation based on precipitation time of titanium surfaces immersed in modified simulated body fluid (Modified simulated body fluid에 침전한 티타늄 표면에서 침전 기간에 따라 나타나는 파골 세포의 분화억제 양상)

  • Chang, Hyun-min;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.142-149
    • /
    • 2019
  • Purpose: The purpose of this study is to investigate the changes of osteoclast differentiation inhibition according to the period of precipitation when titanium disks were immersed in Modified simulated body fluid (mSBF). Materials and methods: Titanium alloy (Ti grade III) disks with machined surfaces and anodized surfaces were immersed in distilled water and mSBF, respectively. The immersion periods were 7 days, 14 days, 21 days and 28 days, and the control group was immersed in distilled water for each period. RAW 264.7 cells capable of differentiating into osteoclasts were used to measure the number of adherent cells, the measurement of TRAP activity, and the expression pattern of NFATc1 by western blotting. Results: The degree of inhibition of osteoclast differentiation was found to be statistically significant when the disks were immersed in mSBF for more than 14 days on both machined surfaces and anodized surfaces. There was no correlation between immersion time and cell attachment. When the disks were immersed for more than 14 days, TRAP activity was decreased and NFATc1 expression was inhibited. Futhermore, the decrease in TRAP activity and the inhibition of NFATc1 expression remained unchanged. Conclusion: Immersion of titanium disks in mSBF for more than 14 days can prevent RAW 264.7 cells from differentiating into osteoclasts. Inhibition activity does not change even if the immersion period is for more than 14 days.