• Title/Summary/Keyword: 특성파형

Search Result 921, Processing Time 0.029 seconds

Influence of Sustaining Frequency on the luminous Efficiency in AC-PDP (교류형 플라즈마 디스플레이에 있어서 유지방전 주파수에 따른 발광 효율에 미치는 영향)

  • 정의선;김대일
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.1-5
    • /
    • 2000
  • Recently alternating-current Plasma Display Panel(AC-PDP) is in the spotlight as a digital television and high definition television. The panel structure widely adapted in commercial AC-PDP is three electrodes surface discharge type. At present time, the luminous efficiency is around 1lm/W, it should be a key factor for the commercialization. For the high luminous efficiency, the development of panel structure is necessary. At a given panel structure, a driving method should be optimized to get a sufficient luminous efficiency. The display image of AC-PDP could be realized by the repeated light emission from the discharge. Because most of discharge power is consumed in the sustaining period, the optimization of sustaining waveform is very important for the high luminous efficiency. ADS (Address and Display period Separated) driving method is commonly used. The average driving frequency of ADS driving method is ranged by several tens kilo of [kHz], however the actual frequency of sustaining period is in range of 100[kHz] to 200[kHz]. Based on this study, when the phosphor emits the visible light, it has a decay time of few milliseconds due to the material transfer to the phosphor to emit the visible light. Consequently the luminous efficiency decreases in proportion to the driving frequency. It is found that the luminous efficiency could be significantly improved by the low frequency sustaining driving method.

  • PDF

Phonatory Caracteristics of Vwels and Resonant Consonants using the Electroglottography (전기성문파형검사를 이용한 모음과 공명 자음의 발성특성)

  • Choi, Seong-Hee;Nam, Do-Hyun;Lim, Jae-Yol;Lim, Sung-Eun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.133-140
    • /
    • 2004
  • Background and Objectives : Vowels and resonant including nasals and liquid are produced with vocal folds vibration have been used for voice therapy of hyperadduction patients. This study was conducted to investigate phonatory characteristics of vowels and resonant consonants through the EGG measures from Lx. Speech studio (Laryngograph Ltd, UK). Materials and Method : 7 male adults produced sustained vowel /a/, /i/, /u/, nasals /m/, /n/, /${\eta}$/and liquid /I/ and read the sentences (1nasals-liquid sentence, 1 non-nasals-liquid sentence) and tongue-tip trill and humming. Fx(Hz), Ox(%) were obtained of vowels, nasals, liquid and each of the posterior vowel /a/ of /ma/, /na/, /la/, /ha/ with same F0(around F#165Hz) and amplitude (75${\pm}$5db). And also DFx(Hz), DQx(%), CFx(%) and CAx(%) were obtained from reading two kinds of sentences. Results : Qx(%) was the highest in /u/ of vowels, and nasal/n/ of the resonant consonants and nasals-liquid sentence was higher Qx than non-nasals-liquid sentence but significant differences were not found. Qx(%) of the posterior vowel /a/ of nasal consonants/n/ was higher than in the isolated vowel/a/ and other posterior vowel of resonant consonants and fricatives /h/. Regularity or periodicity and higher Qx were observed in the nasals-liquid sentence than non-nasals-liquid sentence in graphs of QxFx & CFx produced by Quantiative analysis. In the nasalance score, /u/vowel was significant higher among the vowels and /I/ liquid was significant lower among the resonant consonants and nasals-liquid sentence is higher than non-nasals -liquid sentence. CQ(%) was not significantly correlated with nasalance(%). Conclusion : These findings might signify resonant phonation was not correlated with nasalance.

  • PDF

Automated Velocity Measurement Technique for Unconsolidated Marine Sediment (해양퇴적물의 자동음파전달속도 측정장치)

  • Kim, Dae-Choul;Kim, Gil-Young;Seo, Young-Kyo;Ha, Deock-Ho;Ha, In-Chul;Yoon, Young-Seok;Kim, Jeng-Chang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.4
    • /
    • pp.400-404
    • /
    • 1999
  • The conventional mercury delay method to measure compressional wave velocity of unconsolidated sediment is inconvenient because the signal must be analyzed on the oscilloscope and the mercury column has to be calibrated between measurements. We developed an automated compressional wave velocity measurement technique by connecting an oscilloscope and a PC with a GPIB (General Purpose Interface Bus) card. The GPIB card buses signals from the oscilloscope to the PC where the signal from a sample is analyzed and compared to the input pulse thereby the compressional wave velocity of the sample is computed and recorded automatically. Differences between the mercury delay method and the automated measurement technique are negligible except the slightly greater velocity in the automated measurement technique. We concluded that the new technique can be used to measure the velocity for unconsolidated marine sediment. It also has an advantage to calculate sediment attenuation through the processing of waveform using the spectral ratio technique.

  • PDF

3D analysis of fracture zones ahead of tunnel face using seismic reflection (반사 탄성파를 이용한 터널막장 전방 파쇄대의 3차원적 예측)

  • Lee, In-Mo;Choi, Sang-Soon;Kim, Si-Tak;Kim, Chang-Ki;Jun, Jea-Sung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.4
    • /
    • pp.301-317
    • /
    • 2002
  • Recently, a geophysical exploration technology is frequently utilized in the civil engineering field as well as in the resource exploration. It might be important for civil engineers to understand the fundamental theory of seismic survey and limitation of the technique when utilizing these techniques in the civil engineering field. A 3-dimensional migration technique based on the principle of ellipsoid to predict the fractured zone ahead of tunnel face utilizing the tunnel seismic survey was proposed so that the geometry of the fractured zone can be estimated, i.e. the angle between tunnel axis and discontinuity zone, and the dip. Moreover, a numerical analysis technique to simulate the TSP (Tunnel Seismic Prediction) test was proposed in this paper. Based on parametric studies, the best element size, the analysis time step, and the dynamic characteristics of pressure source were suggested to guarantee the stability and accuracy of numerical solution. Example problems on a hypothetical site showed the possibility that the 3-dimensional migration technique proposed in this paper appropriately estimate the 3D-geometry of fractures ahead of tunnel face.

  • PDF

Analysis of Characteristics of Seismic Source and Response Spectrum of Ground Motions from Recent Earthquake near the Backryoung Island (최근 백령도해역 발생지진의 지진원 및 응답스펙트럼 특성 분석)

  • Kim, Jun-Kyoung
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.274-281
    • /
    • 2011
  • We analysed ground motions form Mw 4.3 earthquake around Backryoung Island for the seismic source focal mechanism and horizontal response spectrum. Focal mechanism of the Backryoung Islands area was compared to existing principal stress orientation of the Korean Peninsula and horizontal response spectrum was also compared to those of the US NRC Regulatory Guide (1.60) and the Korean National Building Code. The ground motions of 3 stations, including vertical, radial, and tangential components for each station, were used for grid search method of moment tensor seismic source. The principal stress orientation from this study, ENE-WSW, is consistent fairly well with that of the Korean Peninsula. The horizontal response spectrum using 30 observed ground motions analysed and then were compared to both the seismic design response spectra (Reg Guide 1.60), applied to the domestic nuclear power plants, and the Korean Standard Design Response Spectrum for general structures and buildings (1997). Response spectrum of 30 horizontal ground motions were used for normalization with respect to the peak acceleration value of each ground motion. The results showed that the horizontal response spectrum revealed higher values for frequency bands above 3 Hz than Reg. Guide (1.60). The results were also compared to the Korean Standard Response Spectrum for the 3 different soil types and showed that the vertical response spectra revealed higher values for the frequency bands below 0.8 second than the Korean Standard Response Spectrum (SD soil condition). However, through the qualitative improvements and quantitative enhancement of the observed ground motions, the conservation of horizontal seismic design response spectrum should be considered more significantly for the higher frequency bands.

Temperature Changes of Climatic Solar Terms and Their Spatiotemporal Characteristics in South Korea (우리나라 기후 절기별 기온 변화의 시공간적 특성 분석)

  • Jin, Mi Jeong;Park, Sunyurp
    • Journal of the Korean Geographical Society
    • /
    • v.50 no.1
    • /
    • pp.23-36
    • /
    • 2015
  • The temperature change patterns of climatic solar terms and their climatic fitness were analyzed. Harmonic analysis based on thirty-year(1981-2010) time-series data from sixty one weather stations across South Korea showed that the central peaks of the extreme heat had shifted toward start of autumn with increasing mean temperature. The overall climatic fitness of solar terms, such as major heat, frost descent, major snow, and major cold, was low, and it showed significant regional variations. The actual meteorological phenomenon representing each climatic solar term was observed much later than the day of the solar term at most weather stations. The number of observations, where an actual meteorological condition for each climatic solar term was recorded within ${\pm}1$ week from the day of that solar term, ranged only from 7.7% to 40.4% of the entire data. Study results also showed that the climatic fitness of major heat, frost descent, and major snow gradually changed in the east-west direction. Major cold, a solar term with higher climatic fitness, was influenced more strongly by latitude than longitude. Considering geographically uneven magnitude and trends in temperature changes, rearrangement and adjustment of time intervals between the solar terms may help us improve their applicability as realistic indicators of seasonal changes.

  • PDF

Implementation of the BLDC Motor Drive System using PFC converter and DTC (PFC 컨버터와 DTC를 이용한 BLDC 모터의 구동 시스템 구현)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.62-70
    • /
    • 2007
  • In this paper, the boost Power Factor Correction(PFC) technique for Direct Torque Control(DTC) of brushless DC motor drive in the constant torque region is implemented on a TMS320F2812DSP. Unlike conventional six-step PWM current control, by properly selecting the inverter voltage space vectors of the two-phase conduction mode from a simple look-up table at a predefined sampling time, the desired quasi-square wave current is obtained, therefore a much faster torque response is achieved compared to conventional current control. Furthermore, to eliminate the low-frequency torque oscillations caused by the non-ideal trapezoidal shape of the actual back-EMF waveform of the BLDC motor, a pre-stored back-EMF versus position look-up table is designed. The duty cycle of the boost converter is determined by a control algorithm based on the input voltage, output voltage which is the dc-link of the BLDC motor drive, and inductor current using average current control method with input voltage feed-forward compensation during each sampling period of the drive system. With the emergence of high-speed digital signal processors(DSPs), both PFC and simple DTC algorithms can be executed during a single sampling period of the BLDC motor drive. In the proposed method, since no PWM algorithm is required for DTC or BLDC motor drive, only one PWM output for the boost converter with 80 kHz switching frequency is used in a TMS320F2812 DSP. The validity and effectiveness of the proposed DTC of BLDC motor drive scheme with PFC are verified through the experimental results. The test results verify that the proposed PFC for DTC of BLDC motor drive improves power factor considerably from 0.77 to as close as 0.9997 with and without load conditions.

Evaluation of Nonlinear Response for Moment Resisting Reinforced Concrete Frames Based on Equivalent SDOF System (등가 1 자유도계에 의한 철근콘크리트 모멘트 골조구조의 비선형 지진응답 평가법의 검토)

  • 송호산;전대한
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.9-16
    • /
    • 2003
  • To evaluate the seismic performance of multistory building structures use an equivalent SDOF model to represent the resistance of the structure to deformation as it respond in its predominant mode. This paper presents a method of converting a MDOF system into an equivalent SDOF model. The principal objective of this investigation is to evaluate appropriateness of converting method through perform nonlinear time history analysis of a multistory building structures and an equivalent SDOF model. The hysteresis rules to be used an equivalent SDOF model is obtained from the pushover analysis. Comparing the peak inelastic response of a moment resisting reinforced concrete frames and an equivalent SDOF model, the adequacy and the validity of the converting method is verified. The conclusion of this study is following; A method of converting a MDOF system into an equivalent SDOF model through the nonlinear time history response analysis is valid. The representative lateral displacement of a moment resisting reinforced concrete frames is close to the height of the first modal participation vector \ulcorner$_1{\beta}$${_1{\mu}}=1$. It can be found that the hysteresis rule of an equivalent SDOF model have influence on the time history response. Therefore, it necessary for selecting hysteresis rules to consider hysteresis characteristics of a moment resisting reinforced concrete frames.

Design Wave Transformation in Finite Depth due to Wave-Current Interaction (파랑-해류 상호작용에 의한 천해 설계파랑 변형)

  • Kang, See-Whan;Ahn, Suk-Jin;Eom, Hyun-Min;Cho, Hyu-Sang
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.4
    • /
    • pp.308-315
    • /
    • 2009
  • Wave-current interaction due to strong ambient currents causes to alter wave properties such as wave height, wave profile and wave spectrum. In this study we first examined the SWAN model's applicability by comparing with an analytical solution of Suh et al. (1994) for wave-current interaction in finite water-depth. Numerical experiments using SWAN model have been conducted for Garolim Bay to estimate the design waveheights influenced by strong tidal currents. For the design wave periods of 8~10 sec, the design wave height of 3 m in NNW direction was increased by up to 40% when the incident waves encounter the opposing currents of 1.4 m/s while the wave height was reduced by 26% due to the following currents of 1.1 m at the bay mouth. This result indicates that the effect of wave-current interaction must be included to determine the design wave height if there exists a strong current.

Accuracy Evaluation of Respiratory Air Flow Transducer for Artificial Ventilation (인공호흡시 호흡기류 계측 센서의 정확도 평가)

  • Lee, In-Kwang;Park, Mi-Jung;Kim, Kyoung-Ok;Shin, Eun-Young;Shon, Ho-Sun;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.425-431
    • /
    • 2015
  • Measurement accuracy was evaluated for the respiratory air flow transducer developed for applications under emergent situations. Pressure-Flow calibration equation was obtained by acquisition of air flow signals from the transducer in response to 6 flow waveforms, similar to those of artificial ventilation, generated by the standard flow generator system. Tidal volume and maximal flow rate were calculated on the flow signal then compared with the error-free data obtained by the linear displacement transducer of the flow generator system. Mean relative error of the tidal volume was within 3% and that of the maximal flow rate, approximately 5%, demonstrating accurate enough measurements. Therefore, the transducer could be applied to emergent situations to monitor the respiratory air flow signal as well as diagnostic parameters in real time.