• Title/Summary/Keyword: 토크비

Search Result 490, Processing Time 0.027 seconds

Effect of Low Calorific Natural Gas on Performance and Emission Characteristics of Engine (저발열량 천연가스가 엔진 성능 및 배기특성에 미치는 영향)

  • Lee, Sungwon;Lim, Gihun;Park, Cheolwoong;Choi, Young;Kim, Changgi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1129-1135
    • /
    • 2013
  • In this, three types of natural gas were employed to investigate the effect of low-calorific natural gas on the performance of and emissions from a heavy-duty CNG engine. The performance and emission characteristics were analyzed by conducting a full-load test, WHSC mode test, and WHTC mode test. The results showed that the torque of low-calorific natural gas with $9,800kcal/Nm^3$ of higher heating value decreased by 4.4 compared to that of the current natural gas with $10,400kcal/Nm^3$ of heating value. With low-calorific fuels, CO, $CO_2$, and $NO_x$ emissions decreased. However, THC emissions increased. According to the WHSC and WHTC mode test results, the thermal efficiency increased and the emission characteristics showed a similar trend to the full-load test results. Low-calorific natural gases cause a decrease in torque at full-load operation conditions and an increase in hydrocarbon emissions.

Safety Evaluation of Radioactive Material Transport Package under Stacking Test Condition (방사성물질 운반용기의 적층시험조건에 대한 안전성 평가)

  • Lee, Ju-Chan;Seo, Ki-Seog;Yoo, Seong-Yeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.1
    • /
    • pp.37-43
    • /
    • 2012
  • Radioactive waste transport package was developed to transport eight drums of low and intermediate level waste(LILW) in accordance with the IAEA and domestic related regulations. The package is classified with industrial package IP-2. IP-2 package is required to undergo a free drop test and a stacking test. After free drop and stacking tests, it should prevent the loss or dispersal of radioactive contents, and loss of shielding integrity which would result in more than 20 % increase in the radiation level at any external surface of the package. The objective of this study is to establish the safety test method and procedure for stacking test and to prove the structural integrities of the IP-2 package. Stacking test and analysis were performed with a compressive load equal to five times the weight of the package for a period of 24 hours using a full scale model. Strains and displacements were measured at the corner fitting of the package during the stacking test. The measured strains and displacements were compared with the analysis results, and there were good agreements. It is very difficult to measure the deflection at the container base, so the maximum deflection of the container base was calculated by the analysis method. The maximum displacement at the corner fitting and deflection at the container base were less than their allowable values. Dimensions of the test model, thickness of shielding material and bolt torque were measured before and after the stacking test. Throughout the stacking test, it was found that there were no loss or dispersal of radioactive contents and no loss of shielding integrity. Thus, the package was shown to comply with the requirements to maintain structural integrity under the stacking condition.

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Speed Control Of The Magnet Gear-Based Speed Reducer For Non-contact Power Transmission (비접촉 동력 전달을 위한 마그네트 기어 기반 감속기의 속도 제어에 관한 연구)

  • Jung, Kwang Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.380-388
    • /
    • 2016
  • Using the magnet gear, it is possible to transmit power without mechanical contact. As the drive shaft in a magnet gear-based speed reducer system is isolated from the drive shaft, the system is a two-inertia resonance system that should cope with an external load with the limited air-gap stiffness. On the other hand, the drive shaft or low-speed side is controlled only by the torque of the drive shaft through an air-gap, and the excessive oscillation or the slip can then be generated because of an abrupt disturbance that is different from the general mechanical gear system. Therefore, the disturbance loaded at the low speed side should be measured or estimated, and considered in the control of the driving shaft. This paper proposes a novel full-state feedback controller with a reduced-order observer for the speed reducer system using a magnet gear with a unified harmonic modulator. The control method was verified by simulation and experiment. To estimate the load at the low speed side, a novel observer was designed, in which the new state variable is introduced and the new state equation is formulated. Using a full-state feedback controller including the observer, the test result against disturbance was compared with two D.O.F PI speed controllers. The pole slip was compensated within relatively a short time, and the simulation result about the estimated variable shows a similar tendency to the test result. The test results showed that the magnet gear-based reducer can be applied to an accurate servo system.

Cross Resistance and Point Mutation of the Mitochondrial Cytochrome b of Bifenazate Resistant Two-spotted Spider Mite, Tetranychus urticae (Bifenazate 저항성 점박이응애에 대한 교차저항성과 미토콘드리아 cytochrome b의 점돌연변이)

  • Lee, Kyo-Ri;Koo, Hyun-Na;Yoon, Chang-Mann;Kim, Gil-Hah
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.3
    • /
    • pp.247-254
    • /
    • 2010
  • Two-spotted spider mite, Tetranychus urticae was collected from the rose greenhouse in Chilgok, Gyeongbuk Province in December 2000. This population has been selected for ten years with bifenazate (over 450 times), and increased 855.9 fold in resistance as compared with susceptible strain (S). Cross resistance of bifenazate resistant (BR) strain to eight miticides was investigated. The BR strain exhibited high and low cross resistance to acequinocyl (614.0 fold) and to chlorfenapyr (9.1 fold), respectively. Against fenazaquin (0.3 fold) and fenpyroximate (0.1 fold), however, showed the strain negatively correlated cross resistance. Each strain collected in Choeng-ju (CJ), Kang-jin (KJ), and Chung-ju (CUJ) showed 5.5-, 964.5-, and 21.8-fold resistance to bifenazate, respectively. The detoxifying enzymes of the BR strain showed 1.6-fold activity in cytochrome $P_{450}$-dependent monooxygenase ($P_{450}$) as compared with susceptible one. By comparing the mitochondrial cytochrome b (cytb) sequence, G126S point mutation was detected in the BR and KJ strains.

Three-dimensional finite element analysis according to the insertion depth of an immediately loaded implant in the anterior maxilla (상악 전치부 즉시하중 임플란트의 식립 깊이에 따른 삼차원 유한요소 분석)

  • Park, Cheol-Woo;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of the insertion depth of an immediately loaded implant on the stress distribution of the surrounding bone and the micromovement of the implant using the three-dimensional finite element analysis. Materials and methods: A total of five bone models were constructed such that the implant platform was positioned at the levels of 0.00 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm depth from the crest of the cortical bone. A frictional coefficient of 0.3 and the insertion torque of 35 Ncm were simulated on the interface between the implant and surrounding bone. A static load of 178 N was applied to the provisional prosthesis with a vertical load in the axial direction and an oblique load at $30^{\circ}$ with respect to the central axis of the implant, then a finite element analysis was performed. Results: The implant insertion depth significantly affected the stress distribution on the surrounding bone. The largest micromovement value of the implant was $39.34{\mu}m$. The oblique load contributed significantly to the stress distribution and micromovement in comparison to the vertical load. Conclusion: Increasing the implant insertion depth was advantageous in dispersing the concentrated stress in the cortical bone and did not significantly affect the micromovement associated with early osseointegration failure.

Evaluation of factors affecting sensory neural hearing loss (감각신경성 청력손실에 영향을 미치는 제 요인에 관한 연구)

  • Hong, Seong-Chul;Bae, Seong-Wook;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.2 s.61
    • /
    • pp.249-264
    • /
    • 1998
  • Reports on a potential relationship between sensory neural hearing loss(SNHL) and cardiovascular or hematologic factor show that the results are controversial. A detailed analysis of risk factors in the development of SNHL was carried out in 3,050 non-noise exposed healthy worker. The mean hearing threshold of both ears at 500, 1000, 2000, 4000, 8000Hz was measured and the effect of age, possible cardiovascular risk factor and hematologic factor (blood viscosity and hemostatic factors) on SNHL were evaluated. first, each of these were associated with loss of hearing sensitivity when univariately and multivariatively analysed. In a multiple regression model, age, sex, body mass index, WBC and total cholesterol level were independently associated with the mean of hearing sensitivity decrease at 4000 and 8000Hz. Second, study subjects were divided into two group (normal vs SNHL) and we compare the possible risk between both groups, and analysed univariate and multivariative logistic model. In a multiple logistic regression model, age, sex, body mass index, WBC and total cholesterol level, total protein, platelet were independently associated with SNHL. Our results show that we have some reliable indices of susceptibility to SNHL using cardiovascular measures or biochemical factor, but future, more extensive studies are required.

  • PDF

Motorsports and Engineering Aspects (모터스포츠의 공학적 접근)

  • 장성국
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.24 no.5
    • /
    • pp.98-103
    • /
    • 2002
  • 이제 카트 정렬과 휠 셋업에 필요한 최적의 변수들을 알아보았다. 실제 세팅은 위에서 언급한 내용 이외에도 많은 것들을 고려하여야 한다. 타이어 접지력의 세팅은 경기장, 날씨, 제품의 불 균일성 등을 고려하여 야 한다. 즉, 어떤 경기장은 코너의 반경이 다른 경기 장 보다 크며 어떤 경기장은 코너가 매우 많기도 하여 세팅을 상황에 맞게 하여야 하는 것이다. 각각의 변수를 세팅할 경우는 중간 값을 취하는 것이 바람직하여 이 중간 값을 취하는 것이 바람직하며 이 중간 값을 각각의 경기장의 특성에 맞추어 변화시키면 되는 것이다. 예를 들면, 접지력이 작게 발생되는 경기장(혹은 매우 추운날씨) 에서는 캐스터를 코기 하여 초기 회전 발생이 용이하게 할 수도 있다. 또한 토우인 값을 크게 하여 타이어가 마찰을 더욱 많이 발생하여 타이어의 온도가 급격히 상승하여 원하는 접지력의 수준에 용이하게 도달할 수 있게 하는 것이다. 그러나 이러한 세팅은 다른 핸들링 문제를 야기할 수 있다는 것을 이해하여야 하며 이러한 문제를 해결하는 또 다른 노력이 필요하게 되는 것이다. 가장 중요한 것은 후륜 내측으로부터는 조종 성능을 향상시키는데 필요한 접지력을 거의 기대하지 못한다는 것이며 마찰이 적게 발생하여 손쉽게 동력 손실을 초래하고 있다는 것이다. 그러므로 회전을 할 경우에도 속도를 낮추어서는 안되며 이렇게 하이야 핸들링이 매우 용이하게 되는 것이다. 그러나 위의 설명에서도 보았듯이 일부 세팅을 변경하면 여러 곳이 그 효과가 나타난다. 예를 들어 후륜의 간격을 변화시키면 카트에서 무게이동 뿐만 아니라 회전 시에 가속이나 감속에 의한 회전 토크의 효과도 달라지게 된다. 특정한 세팅의 변화가 어떻게 작용할 것이라는 확신을 가지고 있다고 할지라도 세팅에서 가장 중요한 것은 주행 기록이다. 여기서 설명되어진 많은 내용이 주행 기록을 향상시키기를 바라는 바이다.간이 육색과 총육색소 함량에는 영향을 미치지 않는 것으로 나타났다. 관능적 특성평가 중 육색과 육즙참출은 대조구와 비교하여 CLA급여 처리구가 유의적인 차이가 없었으나, 근내지방 축적 정도와 전체적인 기호성은 대조구에 비하여 CLA 급여 처리구가 유의적으로 높은 평가를 받았다(p<0.05). 간격은 술 후 1년 후까지도 지속적으로 감소하는 경향을 보였다. 따라서 이 기간동안에는 추적관찰이 필요한 것으로 생각된다.경미하게 나타났으며, 이는 2% 흥국 첨가식이의 섭취로 인한 bromobenzene 대사 및 유해산소 해독의 촉진에 기인되기 때문일 것으로 생각된다.다.과 및 지질과산화억제효과의 순과 일치하였다. 총 flavonoid 함량은 DPPH 라디칼 제거효과에 대한 $IC_{50}$/ 값과 높은 상관관계(r=-0.9924, p<0.01)를 나타내었다.이 우수한 심근보호 효과를 나타내나, 허혈시간이 2시간을 초과하면 심근의 혈역학적 기능과 미세구조의 변화는 중등도의 저온(22∼24$^{\circ}C$)에서 유의하게 악화되었다. 이 같은 결과로 볼 때 심근 허혈시간이 2시간을 초과한다면 심근 온도를 낮추어야 할 것으로 판단된다. 7.2, with 64.0% of office workers having an average level between 6- and 9. The degree of stress was higher for females than males, for unmarried salaried and hot-tempered persons. Those not doing exercise were subject to the highest levels of stress, and those a having sufficient sleep were found to be subject to less stress.

  • PDF

The Assessment of Ultraviolet Radiation in Vegetable Growth (식물생장(植物生長)에 미치는 자외선(紫外線)의 효과(效果))

  • Kim, Hyeong-Ok;Moon, Doo-Khil;Lee, Shin-Chan;Kim, Yong-Ho;Song, Pill-Soon
    • Korean Journal of Environmental Agriculture
    • /
    • v.3 no.1
    • /
    • pp.63-70
    • /
    • 1984
  • The terrestrial UV flux rapidly increased in late spring, as measured by the chemical actinometry at two elevations (near sea level and 1,100m above sea level) on Jeju Island. More intense UV fluxes were observed at higher altitudes. Any harmful effects of solar UV-B on the growth of soybean were not detected in UV-B-exclusion experiment. To ascertain the effect of UV radiation on vegetative growth, intact (㏖ wt 124000) and large (${\sim}120000$) phytochromes were irradiated with UV-B radiation. In intact phytochrome, the Pfr form accounts for 60% of the total phytochrome under stationary state conditions, whereas it accounts for 50% in large phytochrome. Calculated quantum yields for the forward and the backward phototransformations of phytochrome by UV were ${\phi}r=0.016$ and ${\phi}fr=0.010$ in intact phytochrome, and ${\phi}r={\phi}fr=0.012$ in large phytochrome, respectively.

  • PDF

Three-dimensional Imaging with an Endoscopic Optical Coherence Tomography System for Detection of Airway Stenosis (기도협착 측정을 위한 내시경 광 결맞음 단층촬영법을 이용한 3차원 이미징)

  • Kwon, Daa young;Oak, Chulho;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.243-248
    • /
    • 2019
  • The respiratory tract is an essential part of the respiratory system involved in the process of respiration. However, if stenosis occurs, it interferes with breathing and can even lead to death. Asthma is a typical example of a reversible cause of airway narrowing, and the number of patients suffering from acute exacerbation is steadily increasing. Therefore, it is important to detect airway narrowing early and prevent the patient's condition from worsening. Optical coherence tomography (OCT), which has high resolution, is suitable for observing the microstructure of tissues. In this study we developed an endoscopic OCT system. We combined a 1300-nm OCT system with a servo motor, which can rotate at a high speed. A catheter was pulled back using a linear stage while imaging with 360° rotation by the motor. The motor was selected considering various requirements, such as torque, rotational speed, and gear ratio of pulleys. An ex vivo rabbit tracheal model was used as a sample, and the sample and catheter were immobilized by acrylic structures. The OCT images provided information about the structures of the mucosa and submucosa. The difference between normal and stenosed parts in the trachea was confirmed by OCT. Furthermore, through a three-dimensional (3-D) reconstruction process, it was possible to identify and diagnose the stenosis in the 3-D image of the airway, as well as the cross-sectional image. This study would be useful not only for diagnosing airway stenosis, but also for realizing 3-D imaging.