• Title/Summary/Keyword: 토출량 시험

Search Result 14, Processing Time 0.023 seconds

measuring leakage in air lines

  • 임광규
    • Cement
    • /
    • s.47
    • /
    • pp.69-73
    • /
    • 1972
  • 본 시험은 현장에서 실시 가능한 간이식 측정 방법에 의하여 실시되었으며 pipe line의 점검, 보수 등의 불철저로 인한 air leakage량은 전체 압기 토출량의 12.42$\%$에 달하고 있다.

  • PDF

Development of Accelerator Control System for Wet Shotcrete Spraying Equipment (습식 숏크리트 뿜칠 장비의 급결제 유량 제어 시스템 개발)

  • Tae-Ho, Kang;Soo-Ho, Chang;Soon-Wook, Choi;Jin-Tae, Kim;Bong-Gyu, Kim;Chulho, Lee
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.353-362
    • /
    • 2022
  • The wet shotcrete refers to a method in which all materials are mixed and then supplied to the spraying device, compressed air is added to the nozzle, and the spraying speed is improved to spray on the target surface. In order to reproduce the amount of shotcrete used in the wet method in the field and the situation at the laboratory scale, it is essential to control the discharge amount of the equipment. In this study, in order to increase the reproducibility of field conditions at the laboratory scale, a flow control system for shotcrete mortar spraying equipment was developed and applied to the equipment. To verify the developed equipment, a discharge control test using water and mortar was performed. In the developed control system, the discharge was smoothly controlled according to the user input value for the mono pump, but the discharge was not properly controlled according to the input value for the screw pump because of a reducer. When a speed reducer is attached, it is necessary to adjust the operation rate of the screw pump close to the target flow rate by increasing the operation rate of the screw pump while lowering the operation rate of the mono pump.

Development of Simulation Software for Metering Pump of Synthetic Fibers with Image Processing (영상처리 기법에 의한 합섬방사용 미터링 펌프의 시뮬레이션 소프트웨어 개발)

  • Cho Yon-Sang;Bae Myung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.101-106
    • /
    • 2005
  • It needs to accumulate a store of know-how on the design, precision processing and appraisement for metering pump which is a kind of gear pump fer synthetic fibers. But the period and cost fur development is not effective, because designers experience many trial and error for the pump design and manufacturing process. Therefore, in order to curtail the period and cut down expenses, the analysis and simulation system is required for a designed metering pump. In this study, the pump simulation software was developed with the visual C++ language and the image processing algorithm, and was investigated through a discharge test for the planetary gear type metering pump.

Study on Characteristics of Car Air-con Compressor Under Bench System Fuel Economy Simulation Condition (벤치 연비 모사 조건에서 차량용 에어컨 압축기의 특성에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Young-Shin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.705-710
    • /
    • 2012
  • In this study, an experiment on an air conditioning test bench was performed to verify the possibility of fuel economy simulation for the SC03 mode, North America fuel economy certification mode with a/c on condition, one of the vehicle fuel economy evaluation modes. The air conditioning test bench used in this study had each chamber simulating the actual vehicle air conditioning system and the controlling temperature, humidity, and air flow velocity to reproduce environmental conditions. Reliable results were obtained about the compressor RPM and inlet air velocity in front of the condenser corresponding to vehicle speed and air velocity in front of the vehicle, respectively, in the simulation of the SC03 mode, previously performed in CWT, in an air conditioning test bench. It was also discovered that there was a distinct difference in the fuel economy depending on the difference in the compressor displacement in the simulation test of the SC03 mode in the air conditioning test bench under various displacement conditions of the compressor.

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

An Experimental Study on the Pumpability Considering an Effective Ratio of Concrete Delivery Cylinder in Stationary Concrete Pump. (고정식 콘크리트 펌프의 콘크리트 실린더 실효율을 고려한 펌프압송성에 관한 실험적 연구)

  • Kwon, Hae-Won;Bae, Yeoun-Ki;Lee, Jae-Sam;Kim, Seog-Il;Kim, Hyun-Seob;Lee, Jong-Seo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.149-150
    • /
    • 2009
  • The effective ratio of the concrete delivery cylinder has meaning which is important in the performance analysis of stationary concrete pump. But, from experiment or test of most it assumes the effective ratio of the concrete delivery cylinder simply to 90${\sim}$95% level and it is applying. It will follow hereupon and it will be able to grasp the performance of stationary concrete pump by mistake. So we confirm a discharge quantity per time consequently and with, accurately to measure the effective ratio of the concrete delivery cylinder there is a necessity which it will analyze. Experimental resultant existing presumed it apppeared with the fact that it is visible the low-end 70${\sim}$75% level which it sees.

  • PDF

Development of antibacterial PLA fiber to relieve atopy irritation (아토피완화용 PLA 항균사 개발)

  • Yong, Kwang-Joong;Nam, Seung-Min;Ham, Jin-Soo;Yang, Kwang-Wung;Rho, Yong-Hwan
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.11a
    • /
    • pp.52-52
    • /
    • 2011
  • PLA 섬유는 폴리머의 주성분이 옥수수에서 추출한 모노머를 중합한 화학섬유가 아닌 인체친화적인 식물성 소재이며 생분해성이 좋은 친환경 소재로 최근 주목받고 있는 섬유소재이다. 본 연구에서는 아토피완화용 여러 섬유 구조체 개발에서 사용되는 섬유소재중 PLA 원사에 항균성 물질을 혼입하여 PLA 항균사 제조를 위한 연구를 수행하였다. PLA Grade의 점도가 낮아질수록 Grade별 용융 지수값은 차이를 나타내지만 방사온도 $230^{\circ}C$를 변곡점으로 하여 용융점도가 급격히 변하였으며, 특히 방사온도 $240^{\circ}C$의 경우 용융지수가 100을 넘어가고 폴리머의 색깔이 황갈색을 띄어 폴리머의 열분해가 많이 일어났을 것으로 판단되었다. PLA의 적정 방사온도 구간은 $210{\sim}225^{\circ}C$ 구간이 최적이며 그 이상에서는 Color 변화 및 물성 저하가 나타나는 것으로 판단되었다. 항균성 PLA 섬유를 제조하기 위하여 피톤치드계 유기항균제를 이용하였으며, 피톤치드에 기능성 엘라스토머를 사용하여 Capsulation을 진행하였다. 이러한 유기항균제 Powder의 경우 비중이 낮아 표면적로 인하여 마스터배치 칩을 만드는 공정에서 잘 혼합되지 않는 문제점이 발생하였으나, 피톤치드의 함량을 조절하여 PLA와의 마스터배치 칩 제조를 시험하였다. 압출온도와 토출량, Screw 조건(Mixing, Zone)을 시험하여 적정 조건을 설정하였다. 항균사 PLA 섬유는 Sheath/Core 복합방사 형태와 단독사 형태의 2가지 Type을 제조하였다. Sheath/Core 복합방사 폴리머 구성은 Sheath부에 PLA항균사, Core부에 PLA 또는 저융점 PET를 사용하였다. Core부의 폴리머는 제사성에 큰 영향을 미치지 않았으나, 항균 마스터배치의 함량이 증가할수록 Pack압 상승이 급격히 일어나는 단점이 나타났다. 항균제 5% 정도가 혼입되어 있는 경우에 2.1 이상의 정균활성치와 99.8% 정도의 정균감소율 성능을 나타내었다. PLA 단독사의 경우, 항균제 최적 함량은 3% 이상으로 정균활성치 5.5 이상, 정균감소율 99.9%의 우수한 항균특성을 나타내었다.

  • PDF

A Study on Treatment of Asbestos Contaminated Soil with a Field Wind Power Purification Device (현장 풍력정화장치를 이용한 석면 오염토 처리에 관한 연구)

  • Choi, Kwang-Bo;Lee, Seung-Ho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.10
    • /
    • pp.63-71
    • /
    • 2016
  • Soil filling or replacement are routinely applied for soil restoration of domestic asbestos waste contaminated areas. However, since these soil recovery methods could not fundamentally solve the asbestos contamination, number of research on new alternative technologies have been carried. In this study, comprehensive laboratory test results utilizing wind power apparatus are used to design wind power purification device that can be applied in practice. Preliminary tests were carried out with wollastonite or actual asbestos waste contamination soils to study purification efficiency. Asbestos content measured immediately after in-situ test on asbestos-contaminated soil satisfying for purification standard showing less than 0.25% asbestos content from all tests, hence, analyzed to ensure over 90% of clean soil recovery rate and considered to be excellent applicability of future asbestos-contaminated soil purification.

A Study on Development of Shutoff Operating System of Ultra-High Pressure Positive Displacement Pump (초고압 용적형 펌프의 체절운전시스템 개발에 관한 연구)

  • Min, Se-Hong;Kim, Ho-Chul;Sung, Gi-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Ultra-high pressure positive displacement pump can discharge high pressure water with mass volume, which depends on periodic changes in volume that made by rotation motor. Its high efficiency of discharge is one of the most strong point of positive displacement pump. Due to its simple system structure, it can be miniaturized and lightened. Positive displacement pump can discharge high pressure with stable flow rate, irrespective of pressure fluctuate. This is the reason that positive displacement pump was used instead of centrifugal pump. In this study, shutoff operating system was developed for positive displacement pump to secure safety of high pressure operate. This shutoff system contains controller system, electronic clutch, and relief valve, and each part is mutual supplementation. Speed test was carried out in order to check operation of controller program and electronic clutch and fluid flow, venting experiment of the relief valve. It was confirmed that segment system of ultra-high pressure positive displacement pump is operated.

Development of Metal-free Pump and Uni-material Packaging for Cosmetics to Improve Recycling (재활용성 향상을 위한 화장품용 메탈프리 펌프 및 유니소재 패키징 개발)

  • Sang Kyu, Ryu;Ho Sang, Kang;Jae Young, Oh
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.171-174
    • /
    • 2022
  • Cosmetic packing materials tend to be difficult to recycle when discarded due to the cosmetic industry's pursuit of aesthetics, functionality, and high value-added design. Pump packaging, which is widely used for the good preservation and discharge of cosmetics contents, is difficult to be separated and recycled because of a metal spring, which is in charge of pump resilience. In this study, a polypropylene spring was developed to replace the existing metal spring to improve the recyclability of the pump packaging for cosmetics, and was uni-materialized by applying to the cosmetic packing materials with 0.2 ml of discharge amount. In addition, performance test was conducted to verify the equivalence with the existing metal spring pumps as grounds for the commercialization of metal-free uni material pump packaging. The decompression leak test showed no leakage and displayed 14.8~17.5 N of pressing strength, 2.3~8.8 % of deviation in dispensing volume, and 4 occasions of pumping for initial discharge.