• Title/Summary/Keyword: 터빈 외기 온도

Search Result 10, Processing Time 0.028 seconds

Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System (가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석)

  • Park, Hyunwoo;Lee, Jungsoo;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.881-889
    • /
    • 2019
  • The pre-swirl system is the device that minimizes energy loss of turbine cooling airflow from the stationary parts into rotating parts. In this paper, an off-design analysis was conducted for the ambient air temperature and turbine load conditions. The discharge coefficient was constant for ambient air temperature and turbine load. However, adiabatic effectiveness was increased. This is due to the volume flow rate. The volume flow rate was increased at higher ambient temperature and higher turbine load. It means that the volume of cooling air was increased and the cooling performance of the air was improved. Consequently, adiabatic effectiveness increased by 30.46% at 100% turbine load compared to 20% turbine load. And increased by 18.42% at 55℃ ambient air temperature compared to -20℃ ambient air temperature.

A Design Study for Improving Thermal Efficiency of Combined Cycle Power Plants using LNG Cold Energy - Design and Off-design Modelling of Gas-turbine Based Combined Cycle - (LNG 냉열을 이용한 복합발전 플랜트의 성능향상에 관한 연구(I) - 복합화력 발전플랜트의 설계점 및 탈설계점 모델링 -)

  • 오세기;김병일
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.159-165
    • /
    • 1999
  • 복합화력 발전플랜트의 운전에서 특히 하절기의 첨두부하시에 외기온도의 상승으로 인한 가스터빈의 출력 감소를 해결하기 위한 방법으로 LNG 연료가 보유하고 있는 냉열을 이용하여 압축기로 유입되는 공기 온도를 감소시키는 냉각시스템의 개념을 개발하고자 복합화력 발전플랜트에 대한 설계점 및 외기온도 변화에 대한 탈설계점 모델링 연구를 수행하였다. 대상 프랜트는 940 MW 서인천 복합 발전플랜트 모듈의 단위 블록을 선택하였으며 발전플랜트 전용 해석코드인 GateCycle을 이용하여 가스터빈과 증기사이클의 주요 기기 들에 대한 모델을 개발하였다. 개발된 모델의 결과를 대상플랜트의 시운전결과와 비교하여 모델의 적정성을 검증하였다. 출력, 효율, 온도 및 유량 등 주요 설계인자들이 최대 ~1.3%의 상대오차 범위 안에서 만족할 만한 신뢰도를 갖는 것을 확인하였다. 탈설계점 성능해석은 본 논문과 관련한 연구의 주목적인 LNG 냉열에 의한 유입공기 냉각시스템 설계시의 경계변수인 외기온도 증가에 대한 각 사이클의 특성변화를 대상으로 하였다. 종합적으로 외기온도가 증가하면 압축기로 유입되는 공기의 양과 이에 대응하는 소요 연료량이 동시에 감소하므로 연소에 따른 가스터빈의 팽창비가 감소한다. 이로 인하여 외기온도 증가시에 가스터빈 출력감소율은 0.5%/$^{\circ}C$로서 배기가스를 이용하는 증기사이클의 출력감소율 0.2%/$^{\circ}C$에 비해 민감하므로 가스터빈 유입공기의 냉각시스템의 설계는 복합화력발전 플랜트의 효율 향상에 크게 기여할 것으로 예상된다.

  • PDF

Performance Analysis of IGCC Gas Turbine Considering Turbine Operation Condition Change due to Modulation of Nitrogen Dilution (질소희석량 조절에 따른 터빈 운전조건 변화를 고려한 IGCC 용 가스터빈의 성능분석)

  • Kim, Chang Min;Kang, Do Won;Kim, Tong Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1023-1029
    • /
    • 2013
  • The integration between a gas turbine and an air separation unit (ASU) is important in IGCC plants. The portion of ASU air extracted from the gas turbine and the degree of nitrogen supply from the ASU to the gas turbine side are important operating parameters. Their effect on the gas turbine performance and operability should be considered in a wide ambient temperature range. In this study, appropriate nitrogen dilution rate and turbine inlet temperature that satisfy the two limitations of turbine blade temperature and maximum allowable power output were predicted. The air integration was set at zero. The simulation showed that the power output increases and turbine blade temperature decreases as the nitrogen dilution increases. The maximum allowable power output can be obtained under medium and low ambient temperature ranges. Under a high ambient temperature range, the achievable power is less than the maximum power.

A study on the performance enhancement for combined cycle using cold heat of LNG (LNG 냉열을 이용한 복합사이클 발전시스템의 성능개선연구)

  • 김용희;김병일
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.77-80
    • /
    • 1996
  • 우리나라에서 피크부하용으로 사용하는 복합발전이 하계시에서 외기온도가 상승함에 따라 실제로는 정격출력을 내지 못하고 있다. 따라서 본 연구에서는 연료(LNG)의 냉열을 이용하여 가스터빈의 연소용공기를 냉각시킬 경우, 복합발전 시스템의 성능변화를 분석하기 위하여 시뮬레이션을 수행하였다. 그 결과 LNG의 냉열을 이용하여 연소용공기를 원하는 온도까지 냉각시킬 수 있음을 확인할 수 있었다. 또한 연소기로 연료를 투입하기전에 설계온도까지 예열시키는 열교환기를 통해 배기가스에 함유된 현열을 더욱 많이 회수하면서, 가스터빈 투입연료의 온도를 상승시킬 수 있어, 시스템효율이 더욱 상승함을 알 수 있었다. 결론적으로 외기온도가 변하는 경우에, 본 시스템의 도입을 위해서는 경제성분석과 더불어 열교환기 시스템의 최적합성이 추후 진행되어야 할 것이며, 이를 통해 최적의 발전시스템을 구성할 수 있으리라 생각된다.

  • PDF

Performance Analysis of CHP(Combined Heat and Power) for Various Ambient Conditions (외기조건변화에 따른 CHP 성능 해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Kim, Nam-Jin;Lim, Kyung-Bum;Seo, Young-Ho;Kim, Ki-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3353-3359
    • /
    • 2011
  • The co-generation system consisted of gas a turbine, a steam turbine, heat recovery steam generator and a heat exchangers for district heating was investigated in the present study. A back-pressure steam turbine (non-condensing type) was used. A partial load analysis according to the outdoor temperature in winter was conducted and optimal thermal load and power conditions was examined using the commercial computing software Thermoflex. As a result, under a constant thermal load, the power outputs of gas turbine and overall system increased as an outdoor temperature decreased. On the other hand, the reduction in exhaust gas temperature led to the decrease in output of steam turbine. Considering the portion of gas turbine in overall system in terms of the power output, it can be known that the tendency in power output of overall system was similar to that of the gas turbine.

Analysis of Operating Characteristics of 200kW Class Micro Gas Turbine (200kW 급 마이크로 가스터빈의 운전특성 분석)

  • Kim, Jeong Ho;Kang, Do Won;Kim, Tong Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1015-1022
    • /
    • 2013
  • This study simulates the operation of a 200 kW class micro gas turbine that is currently under development. The performance and operating characteristics depending on the load control scheme (constant turbine inlet temperature versus constant turbine exit temperature) and ambient condition were investigated using detailed component performance data. The sensitivities of operating parameters, such as the compressor surge margin and flow path temperatures, according to unit fuel flow change were predicted for a wide load range. The sensitivity analysis showed that the steady state calculation provided useful information about the maximum surge margin reduction during load change.

LNG 냉열을 이용한 복합발전시스템의 성능향상에 관한 연구

  • Oh, Se-Gi;Kim, Byung-Il;Lee, Chan
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1997.10a
    • /
    • pp.3-8
    • /
    • 1997
  • 본 연구에서는 복합발전시스템의 외기온도 변화로 인한 출력저하 문제를 극복할 수 있는 LNG 냉열 이용 복합발전 시스템을 제안하였다. 본 연구에 의해 제안된 LNG 냉열 이용 복합발전 시스템의 타당성을 검토하기 위해 ASPEN과 GateCycle을 이용한 시뮬레이션 모델을 구성하였고, 모델에 의해 예측한 결과를 실제 발전소 성능시험결과와 비교하여, 본 시뮬레이션 방법의 예측정확도를 검증하였다. 본 시뮬레이션 방법을 토대로 LNG 냉열을 이용하여 가스터빈의 유입공기를 냉각시켰을 경우의 복합발전 시스템 성능변화를 분석하였다. 그 결과 LNG 냉열을 이용하여 유입 공기를 원하는 온도까지 냉각시켜 하절기에도 출력을 일정하게 유지시킬 수 있음을 확인할 수 있었고, 이를 위한 기스터빈과 LNG 간의 열교환기 설계기준도 제시하였다.

  • PDF

Improvement of Gas Turbine Performance Using LNG Cold Energy (액화천연가스의 냉열을 이용한 가스터빈의 성능향상)

  • Kim, Tong Seop;Ro, Sung Tack;Lee, Woo Il;Choi, Mansoo;Kauh, Sang Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.653-660
    • /
    • 1999
  • This work describes analysis on the effect of inlet air cooling by the cold energy of liquefied natural gas(LNG) on the performance of gas turbines. Gas turbine off-design analysis program to simulate the influence of compressor inlet temperature variation is prepared and an inlet air cooler is modeled. It is shown that the degree of power augmentation is much affected by the humidity of inlet air. If the humidity is low enough, that is the water content of the air does not condense, the temperature drop amounts to $18^{\circ}C$, which corresponds to more than 12% power increase, in case of a $1350^{\circ}C$ class gas turbine with methane as the fuel. Even with 60% humidity, about 8% power increase is possible. It is found that even though the fuel contains as much as 20% ethane in addition to methane, the power improvement does not change considerably. It is observed that if the humidity is not too high, the current system is feasible oven with conceivable air pressure loss at the inlet air cooler.

Numerical Analysis and Demonstration Test on the Performance of a Static Mixer for mixing Biogas and Town Gas for the 5MW Biogas Turbine (5MW 바이오가스 터빈의 바이오가스와 도시가스 혼합용 정적 혼합기의 성능에 관한 수치해석 및 실증 연구)

  • Cha, Hyoseok;Song, Soonho;Park, Jong Yeon;Kim, Young Il;Mun, Sung Young
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.51-57
    • /
    • 2015
  • The purpose of this study is to verify the performance of a static mixer for mixing of biogas and town gas by numerical analysis and demonstration test. The reason for designing a static mixer is that there is a need to mix town gas with biogas when there is less production of biogas in biogas sites. Non-uniformity in the outlet section was calculated for investigating the performance of a static mixer. Non-uniformity was based on the mole fraction of methane in a mixture of biogas and town gas. Low non-uniformity means that biogas and town gas are mixed well through this static mixer. Also, pressure drop at the outlet section of a static mixer was calculated. The pressure drop is less than 0.2% in this static mixer. This static mixer is suitable for applying to a 5MW bio-gas turbine through the demonstration test in the field.

An Experimental Study on the Ventilation Characteristics of a Wind-Turbine Natural Ventilator According to the Outdoor-Wind Velocity and the Indoor/Outdoor-Temperature Difference (윈드터빈 자연환기 장치의 외기풍속 및 온도차에 따른 환기특성에 관한 실험연구)

  • Han, Dong-Hun;Kim, Yeong-Sik;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.175-184
    • /
    • 2017
  • With the improvement of living standards, the ventilation for the mitigation of indoor or outdoor air-pollution problems has recently attracted a lot of attention. Consequently, the ventilation for the supply of outdoor fresh air into a room is treated as an important building-design factor. The ventilation is generally divided into the forced and natural types; here, the former can control the ventilation rate by using mechanical devices, but it has the disadvantages of the equipment costs, maintenance costs, and noise generation, while the latter is applied to most workshops due to the absence of noise and the low installation and maintenance costs. In this experimental study, the ventilation performance of a typical rotating-type natural ventilator, which is called a "wind turbine," was investigated with the outdoor-wind velocity and the indoor/outdoor-temperature difference. From the experiment results, it was confirmed that the temperature difference of $10^{\circ}C$ corresponds to the ventilation driving force with an outdoor-wind velocity of 1.0 m/s. Additionally, the intake-opening area of a building also exerts a great effect on the ventilation rates.