• Title/Summary/Keyword: 탈황 효율

Search Result 110, Processing Time 0.025 seconds

Comparison of the $SO_2$ Removal Efficiency by Mixing Enhancement Shape (혼합 촉진 장치의 형상에 따른 탈황효율 비교)

  • Chung, Jin-Do;Kim, Jang-Woo;Bae, Young-Peel
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.17-22
    • /
    • 2010
  • The aim of this study is to research applicable possibility of DSI (Dry Sorbent Injection) technique in $SO_2$ removal process using lab-scale facility based on 500MW in capacity coal-fired thermal power plant operated by South Korea N. Power Co., Ltd. To increase the $SO_2$ removal efficiency, it is considered the mixing enhancement as different shapes called lobed-plate and stepplate tested ultimately for optimum shape. Also it tested to analysis $SO_2$ removal efficiency by numbers of injection holes. At experimental it showed the $SO_2$ removal efficiency is higher using mixing enhancement than not installed mixing enhancement and case on the step-plate was shown the most $SO_2$ removal efficiency. Also, $SO_2$ removal efficiency was higher recording which will increase the injection holes case on not installed mixing enhancement. But, the $SO_2$ removal efficiency was higher 4 injection holes case on installed mixing enhancement.

Study on desulfurization performance of Zn-based solid sorbents at high temperature and pressure in the 0.3 bbl/d CTL(Coal-to-Liquid) process integrated with coal gasifier, F-T process and hot gas desulfurization process (석탄가스화기, F-T 공정, 건식탈황공정이 통합된 0.3 배럴/일 규모 석탄액화(CTL) 공정에서 고온, 고압 연속운전에서 아연계 탈황제의 탈황 성능 파악)

  • Park, Young Cheol;Jo, Sung-Ho;Jin, Gyoung Tae;Lee, Seung-Yong;Yi, Chang-Keun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.107.2-107.2
    • /
    • 2010
  • 고온건식탈황기술은 고온고압에서 석탄가스에 함유된 황화합물을 제거하는 기술로 석탄가스화에 의해 생성된 고온의 석탄가스의 열손실을 최소화하여 열효율이 높은 기술이다. 본 연구에서는 석탄으로부터 합성원유를 생산하는 0.3 배럴/일 규모 석탄액화(CTL)공정의 연계운전을 통하여 건식탈황공정의 성능을 평가하였다. 0.3 배럴/일 규모 석탄액화공정은 석탄가스화기, 건식탈황공정, 액화공정으로 구성되어 있으며 30 atm의 고압에서 운전된다. 건식탈황공정은 석탄가스화기와 액화공정 사이에 위치하여 석탄가스화로부터 생성된 석탄가스에 함유된 황화합물을 아연계 건식탈황제에 의해 제거한 후 액화반응기로 공급하여 황화합물에 의한 촉매의 피독을 막아주는 역할을 수행한다. 본 연구에서는 기존에 개발된 두 개의 기포유동층 반응기로 구성된 탈황장치를 30 atm에서 운전이 가능하도록 수정/보완하여 실제 운전압력인 30 atm의 고압에서 연속운전을 수행하였다. 실험 결과 탈황효율은 99% 이상이며 탈황반응기 출구 황화합물의 농도는 1 ppmv 이하로 유지하였다.

  • PDF

A Study of Hydrodynamics and Reaction Characteristics in Relation to the Desulfurization Temperatures of Zn-Based Solid Sorbent in the Lab-scale High Pressure and High Temperature Desulfurization Process (실험실규모 고온고압건식탈황공정의 수력학적 특성 및 탈황온도에 따른 아연계 탈황제의 반응특성 연구)

  • Kyung, Dae-Hyun;Kim, Jae-Young;Jo, Sung-Ho;Park, Young Cheol;Moon, Jong-Ho;Yi, Chang-Keun;Baek, Jeom-In
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.492-498
    • /
    • 2012
  • In this study, hydrodynamics such as solid circulation rate and voidage in the desulfurizer and the reaction characteristics of Zn-based solid sorbents were investigated using lab-scale high pressure and high temperature desulfurization process. The continuous HGD (Hot Gas Desulfurization) process consist of a fast fluidized bed type desulfurizer (6.2 m tall pipe of 0.015 m i.d), a bubbling fluidized bed type regenerator (1.6 m tall bed of 0.053 m i.d), a loop-seal and the pressure control valves. The solid circulation rate was measured by varying the slide-gate opening positions, the gas velocities and temperatures of the desulfurizer and the voidage in the desulfurizer was derived by the same way. At the same gas velocities and the same opening positions of the slide gate, the solid circulation rate, which was similar at the temperature of $300^{\circ}C$ and $550^{\circ}C$, was low at those temperatures compared with a room temperature. The voidage in the desulfurizer showed a fast fluidized bed type when the opening positions of the slide gate were 10~20% while that showed a turbulent fluidized bed type when those of slide gate were 30~40%. The reaction characteristics of Zn-based solid sorbent were investigated by different desulfurization temperatures at 20 atm in the continuous operation. The $H_2S$ removal efficiency tended to decrease below the desulfurization temperature of $450^{\circ}C$. Thus, the 10 hour continuous operation has been performed at the desulfurization temperature of $500^{\circ}C$ in order to maintain the high $H_2S$ removal efficiency. During 10 hour continuous operation, the $H_2S$ removal efficiency was above 99.99% because the $H_2S$ concentration after desulfurization was not detected at the inlet $H_2S$ concentration of 5,000 ppmv condition using UV analyzers (Radas2) and the detector tube (GASTEC) which lower detection limit is 1 ppmv.

Efficient bio-gas desulfurization purification technology development Using ion-exchange fibers (이온교환섬유를 이용한 바이오가스 고효율 탈황정제기술 개발)

  • Tak, Bong-Yeol;Tak, Bong-Sik;Min, Gil-Ho;Lee, Sang-Min;Lee, Won-Gu;Lee, So-A
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.116-116
    • /
    • 2011
  • 바이오 가스 플랜트의 혐기소화 공정에서 발생하는 바이오 가스는 중 유해가스인 황하수소($H_2S$)는 부식성 가스로 수천 PPM농도를 함유하여, 발전기나 가스보일러로 이용하는 경우에는 $H_2S$를 제거하는 탈황공정이 반드시 필요하다. 탈황방식에는 산화철 탈황(건식 탈황)과 생물 탈황이 현재 많이 사용되고 있어나 산화철 탈황은 산화철 pellet이 유화철에 변화하면 탈황능력이 저하되어 pellet을 교환해야 하며 많은 비용이 발생한다. 생물 탈황 방식은 유황산화세균의 서식활동조건(온도, 반응시간, 산소량)확보가 반드시 필요하여 높은 운전기술을 필요로 한다. 본 연구에서는 바이오가스 전처리 기술 중 활성탄 또는 약액을 이용한 기존의 탈황정제방식보다 흡착성능이 뛰어난 이온교환섬유를 이용하여, 황화수소($H_2S$)를 95% 이상 제거할 수 있는 고효율 섬유상 이온촉매 악취제거 시스템 개발을 수행하였다. 이온교환섬유는 방사선 조사를 이용하여 부직포에 라디칼을 인위적으로 형성시켜(그라프트 중합) 양이온 또는 양이온을 교환할 수 있도록 제조된 섬유상의 흡착제로, 이온교환 섬유의 화학적 이온교환과 물리적 흡착 및 탈착반응이 동시에 발생되고, 활성탄/실리카켈 보다 흡착능력이 2~4배 높다. 또한 이온섬유의 재생기능을 이용하여 장기적 다양한 악취($H_2S$, $NH_3$, 아민계, 메르갑탄류, 알데히드 등) 및 유해가스(VOCs, NOx, SOx) 등을 95% 이상 제거할 수 있다.

  • PDF

Effect of Operating Parameters on Microbial Desulfurization of Coal by Acidithiobacillus ferrooxidans. (Acidithiobacillus ferrooxidans에 의한 생물학적 석탄탈황에 미치는 조업인자의 영향)

    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.4
    • /
    • pp.400-407
    • /
    • 2003
  • In microbial coal desulfurization process (MCDP) by using Acidithiobacillus ferrooxidans, the effect of process variables on pyritic sulfur removal efficiency has been investigated. The inhibitory effect of toxic materials contained in coal matrix on the activity of desulfurizing bacteria have been evaluated in coal extracts, and the results showed that the method was useful to evaluate the applicability of a coal which is to be desulfurization to MCDP. The removal efficiency increased with decreasing particle size and decreases with increasing pulp density, but has no significant influence of particle size and pup densities at high pulp densities over 20 wt%. The mass transfers of gaseous nutrients such as oxygen and carbon dioxide into coal slurry with various pulp densities and coal particle size has been studied in an airlift bioreactor. Mass transfer coefficient was independent of pulp density in coal slurry with fine particle below 175 $\mu\textrm{m}$, but significantly decreased with increasing pulp density over 225 $\mu\textrm{m}$. The coal particles over 575 $\mu\textrm{m}$ were significantly settled to the bottom of bioreactor resulting in poor mixing. Considering mass transfer, pulp density and coal mixing, an optimal size of coal particle for the microbial coal desulfurization process seems to be about 500 $\mu\textrm{m}$.

A Study on Desulfurization Efficiency of Limestone Sludge with Particle Size (석회석 슬러지의 입도제어에 따른 배연탈황효율에 관한 연구)

  • Seo, Sung Kwan;Chu, Yong Sik;Shim, Kwang Bo
    • Resources Recycling
    • /
    • v.24 no.6
    • /
    • pp.17-23
    • /
    • 2015
  • Flue gas desulfurization(FGD) is the technique to remove $SO_2$ gas from stack gases of coal-fired plants. Many researcher have studied to replace the desulfurizing agent because FGD systems use a lot of limestone and energy. In this study, we use the limestone sludge which is a by-product of steel industry in order to replace desulfurizing agent of FGD system by control the particle size of limestone sludge. And desulfurization performance test is implemented by investigating $SO_2$ gas removal properties upon the characteristic of the limestone sludge with various particle size.

Microbial Desulfurization of a Bituminous Coal by Iron-Oxidizing Bacteria Thiobacillus ferooxidans (철산화 박테리아 Thiobacillus ferrooxidans에 의한 역청탄의 생물학적 탈황)

  • 류희욱
    • KSBB Journal
    • /
    • v.11 no.2
    • /
    • pp.238-245
    • /
    • 1996
  • Microbial desulfurization characterlstics of a bituminous coal have been determined by using Thiobacillus ferrooxidans. The effects of process variables (such as coal pulp density, particle size and addition of surfactants) on pyrite removal have been investigated in both shake and airlift-bioreactor culture experiments. In shake experiments, pyrite could be removed over 78% for pulp densifies below 20% (w/v) and removed below 40% for pulp densities over 30% (w/v) in 8 days. Pyrite removal decreased with increasing pulp densities, and it also decreased sharply with increasing particle sizes. In airlift bioreactor experiments, pyrite at 50% (w/v) pulp density could be removed about 50%. Its value is much higher than 15% at the same pulp density in a shake experiment. With addition of surfactants, pyrite removal was enhanced in shake experiments significantly, whereas it was slightly decreased in an airlift bioreactor experiment.

  • PDF

Physical Properties and Sulfidation Kinetics of Mn-Based Sorbent for Hydrogen Sulfide Removal (황화수소 제거를 위한 망간계 탈황제의 물리적 특성과 황화반응 속도)

  • Oh, Kwang-Joong;Shon, Byung-Hyun;Choi, Eun-Hwa;Yi, Gang Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2067-2076
    • /
    • 2000
  • The experiments have been made to develop manganese-based sorbent(MT, MFT) for the removal of hydrogen sulfide from simulated hot coal gases. Manganese-based sorbents were tested in an ambient-pressure fixed-bed reactor to calculate H2S removal efficiency. and a three hole jet attrition tester to characterize the sorbent physical properties. According to the experimental results of attrition test. the attrition resistance of 5% bentonite containing sorbent was higher than that of 2% bentonite. The attrition resistances of both sorbents increased with induration temperature. Effects of sulfidation temperature. space velocity. and $H_2S$ concentrations on the $H_2S$ removal efficiency were investigated. Experimental results showed that $H_2S$ could be removed from 5,100ppmv to 20ppmv at $450^{\circ}C$, and to 30~65ppmv at $550{\sim}650^{\circ}C$ for both MT/MFT sorbents. As for the change of space velocity, the breakthrough time was decreased with space velocity.

  • PDF

Prediction of Cleaning Time of Desulfurization Absorber in a Oil-Fired Power Plant through the Operation Data (중유화력발전소의 운전자료를 이용한 탈황 흡수탑의 세정시기 예측)

  • Jang, Yeong-Gi;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.11 no.4
    • /
    • pp.38-46
    • /
    • 2015
  • 중유를 연소하는 D 발전소 탈황설비는 운전시간의 경과에 따라 흡수탑 중간층에 석고가 쌓이고 가스분사 파이프 내에 경질석고 스케일이 부착됨으로써 발전설비 및 탈황설비의 정상적인 운전이 어렵게 된다. 흡수탑 내부에 발생된 스케일을 제거하지 않을 경우에는 탈황효율의 저하에 따른 SO2 배출농도의 증가로 발전가능 최대출력의 하향조정이 발생되고 나아가 발전정지를 초래한다. 스케일 제거를 위한 탈황설비 세정은 발전가능 최대출력의 하향조정이 발생하는 시점으로 결정할 수 있다. 본 연구에서는 탈황설비의 운전 자료를 분석하여 발전가능 최대출력의 하향조정이 발생되기 6주 전은 탈황설비 출구 SO2 농도값이 130ppm을 초과하고 동시에 흡수탑 차압은 380mmH2O을 초과하며, 직전 흡수탑 세정 이후 44주가 경과된 시점이 됨을 확인하였다. 그리고 흡수탑의 세정시기는 세정준비기간 6주와 발전가능 최대출력 하향이 발생되기 6주 전까지의 운전경과일수 44주를 더하여 직전 세정시점으로부터 50주가 경과된 시점임을 예측하였다.

  • PDF

Evaluation and application of grinding index of domestic desulfurization limestone (국내 탈황용 석회석의 분쇄성 지수 평가 및 응용)

  • Seo, Jun Hyung;Baek, Chul Seoung;Cho, Jin Sang;Ahn, Young Jun;Ahn, Ji Whan;Cho, Kye Hong
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • In the flue gas desulfurization process of the coal-fired power plant, the grinding efficiencies of the limestone as the sorbent for desulfurization were compared after BWI and HGI measurements. As a result, the grinding index of the domestic desulfurization limestone were linear inversely proportional relationship with decreasing BWI was observed with increasing HGI. There was a difference in grinding efficiency depending on the chemical composition and crystal structure. Therefore, it is considered that when grinding ability of limestone is measured, the grinding property of the sample can be confirmed even by using HGI which can be measured more easily than BWI which is difficult to measure and takes a long time. The desulfurization efficiency can be improved by selective utilization of limestone depending on the crushing characteristics.